The Effect of Wind Direction on the Cooling Capacity of Short Dry Natural Draft Cooling Towers Operating in Close Proximity
- 27 September 2023
- journal article
- research article
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (2) , 1-37
Abstract
The layout of multiple natural draft dry cooling towers could have a significant influence on the performance of the cooling system in concentrated solar power (CSP) plants; however, this has never been quantified. Hence, this work used computational fluid dynamics (CFD) modeling to analyze the cooling capacity of two short natural draft dry cooling towers (NDDCTs) on a common site for a range of tower spacings, wind-speeds, and wind incidence angles. The results show that the cooling performance of the towers is a strong function of tower spacing and their orientation with respect to the wind direction. It was found that when the wind came at a 90-deg wind incidence angle (i.e., normal to a line drawn between the two towers), their cooling capacity was improved at tower spacings of less than 1.8 tower diameters (1.8D), though for the other tower spacings, there was no interaction between the towers. However, with the wind at 45 deg to the towers, the flow around the towers resulted in a decrease in their cooling capacity at tower spacings of 1.8D and 2.6D. Most interestingly, it was found that orienting the towers in line with the prevailing wind direction delivered improvements in the cooling capacity of up to 30%. This is due to the windward tower acting as a passive windbreak. Hence, as CSP plant capacity is increased, and additional cooling towers are required, these should be placed close to any existing tower and oriented along the line of the prevailing winds.Keywords
This publication has 27 references indexed in Scilit:
- Theoretical Prediction With Numerical and Experimental Verification to Predict Crosswind Effects on the Performance of Cooling TowersHeat Transfer Engineering, 2014
- Flow and heat transfer characteristics of indirect dry cooling system with horizontal heat exchanger A-frames at ambient windsInternational Journal of Thermal Sciences, 2014
- Numerical simulation of solar enhanced natural draft dry cooling towerSolar Energy, 2014
- Optimization design of solar enhanced natural draft dry cooling towerEnergy Conversion and Management, 2013
- Windbreak walls reverse the negative effect of crosswind in short natural draft dry cooling towers into a performance enhancementInternational Journal of Heat and Mass Transfer, 2013
- Solar enhanced natural draft dry cooling tower for geothermal power applicationsSolar Energy, 2012
- Improving cooling efficiency of dry-cooling towers under cross-wind conditions by using wind-break methodsApplied Thermal Engineering, 2006
- The performance of natural draft dry cooling towers under crosswind: CFD studyInternational Journal of Energy Research, 2003
- Numerical simulation of fluid flow and thermal performance of a dry-cooling tower under cross wind conditionJournal of Wind Engineering and Industrial Aerodynamics, 1999
- Full-scale measurement and wind-tunnel testing of wind loading on two neighboring cooling towersJournal of Wind Engineering and Industrial Aerodynamics, 1992