Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Timothy Anderson has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Solar energy landscapes in Nepal: site suitability analysis of solar photovoltaics using a geospatial multi-criteria decision analysis

    by Manisha Kc, Geeta Bhatta, Basant Awasthi, Timothy Anderson, Sunil Prasad Lohani

    Renewable energy deployment is expanding globally owing to rising environmental concerns, rising fuel costs and the need for long-term energy security. However, inadequate evidence-based knowledge and policies to support large-scale renewable energy deployment in developing nations like Nepal are hindering its penetration. Therefore, in this study, high-resolution spatial data in a geographical information system were paired with multi-criteria decision-making and an analytical hierarchy process to identify suitable sites for solar farm development in Nepal. This methodology employs criteria such as climate, economics, topography and environment to assess the spatial suitability of a solar farm. Results showed that only 3% of Nepal's land area is suitable for solar farms, with 1.32% (1798 km2) as highly suitable, 1.6% (2243 km2) as moderately suitable and 0.08% (124 km2) as least suitable. Suitable sites are concentrated in the Terai and hilly regions, reflecting optimal solar radiation, gentle slopes and proximity to infrastructure. Using these areas for solar installations would enhance Nepal's clean energy transition and help achieve its sustainable development goals. In summary, this study provides an analytical basis for the decisions of energy planners, government bodies, specialists and researchers involved in energy planning and policy formulation.

  • Non-uniform Fluidisation of a Square Fluidised Bed Solar Receiver

    by Mustafa Alqudah, Timothy Anderson, Alan Brent

  • Open Access

    The Effect of Air Purification on the Indoor Air Quality in Habitable New Zealand Buildings

    by Logan Nightingale, Nicolas Sandoval, Rhys Jones, Mohammad Al‐Rawi, Timothy Anderson

    Particulate matter (PM) in indoor air, including fungal spores and bacteria, poses significant health risks, especially in poorly constructed and inadequately ventilated buildings that are prevalent in New Zealand. To maintain acceptable living conditions, there is a need to explore ways in which fungal and bacterial populations in habitable buildings can be reduced. In this study, six combinations of four different air treatments (HEPA filtration, UVGI, heating and dehumidification) were evaluated for their ability to reduce airborne fungal and bacterial populations in a stand‐alone ‘sleepout’ style building (ECR) in the Waikato region of New Zealand. Particulate matter (PM 2 . 5 ) sensors and settle plates were used to actively and passively monitor fungal and bacterial populations both inside and outside the ECR during treatments. HEPA filtration resulted in significantly lower fungal populations compared to no treatment; however, there was no observable reduction in bacterial populations from HEPA filtration alone. Overall, HEPA filtration in combination with other treatments was associated with reductions of both fungal and bacterial populations, and room temperature was shown to be a key driver of bacterial counts, but not fungal counts. Viruses were not examined in this study. As such, further studies may be conducted to assess viral loads, as well as optimising room temperatures and configurations to improve reductions of viable airborne bacteria.

  • Open Access

    Investigation of multiple lift-tube air-lift pumps: Experimental evaluation and predictive modelling

    by Noman Yousuf, Timothy Anderson, Michael Gschwendtner

    Due to limited pumping capability the commercial use of the single lift-tube air-lift pump has been confined to very little applications. To overcome the limited pumping capability of single lift-tube air-lift pump, multiple lift-tubes were examined as a way to improve the pumping capacity. Experiments were conducted on air-lift pumps having 2 and 3 lift-tubes. Lift-tubes having the inner diameter of 10 mm and length of 500 mm were used in the experiment. The working fluids used in the experiment were water and air. Tests were performed at three different submergence ratios of 0.3, 0.5 and 0.7. It was found that using multiple lift-tubes is a viable solution as it improves the pumping capacity of the air-lift pump. However, the flow rate and the flow regime of each lift-tube in a multiple lift-tube configuration were observed to be non-uniform. Moreover, due to non-uniform flow regime analytical modelling of a multiple lift-tube air-lift pump showed an inability to accurately predict the pumping characteristics. To overcome this, a novel artificial neural network (ANN) technique was used to predict their pumping capacity. The results showed that the ANN was capable of accurately predicting the performance of the multiple-lift tube bubble pump.

  • Pumped hydro energy storage for energy security in Nepal: A geospatial and economic analysis

    by Prabin Dhakal, Geeta Bhatta, Sharad Chandra Mainali, Krishna Prasad Dulal, Timothy Anderson, Ramchandra Bhandari, Sunil Prasad Lohani


  • Open Access

    CFD Investigation of Particle Temperature in Fluidised Bed Solar Receivers

    by Mustafa Alqudah, Timothy Anderson, Alan Brent

    This study investigates the influence of fluidised bed solar receiver geometries and fluidisation velocity on particle temperature distribution and bed performance, with a focus on evaluating the feasibility of using a square shape for fluidised bed solar receivers. The research compares cylindrical and square bed geometries under varying fluidisation velocities to assess their impact on temperature profiles, and overall receiver performance. The results indicate that increasing fluidisation velocity enhances particle mixing and raises mean particle temperatures across both geometries, with the cylindrical bed showing higher mean temperatures at higher velocity. However, the square bed maintains better temperature uniformity, especially at higher velocity, which is advantageous for minimising hot spots and ensuring stable operation. While increased velocities improve bed dynamics and facilitate rapid collection of intermittent solar power, they also require higher pumping power and can lead to greater heat loss. Despite these benefits, further investigation is needed on the square shape, particularly in exploring uneven fluidisation regimes to reduce higher temperatures at the corners. Overall, the findings suggest that square-shaped fluidised beds offer a promising and feasible design alternative for solar receivers, balancing temperature uniformity and operational efficiency.

  • Open Access

    A parametric analysis of a solar humidification/dehumidification desalination system using a bio‐inspired cascade humidifier

    by Reza Enayatollahi, Timothy Anderson, Roy Nates

    Water scarcity is a significant challenge for a growing world's population, particularly in remote locations where solar energy is plentiful. Of the existing solutions, the Humidification‐Dehumidification (HDH) desalination technique can work effectively with low‐grade energy sources, such as solar. However, HDH desalination systems often have a low yield, leading to a focus on ever‐more complex humidification systems. This work aims to examine the performance of a novel bioinspired humidifier as a low‐cost and effective solution to increase the yield of small‐scale HDH desalination systems. To this end, an HDH desalination system using a cascade humidifier was conceptually developed and parametrically modelled. It was shown that the evaporation rate in the humidifier could be increased by increasing both the air and water flow rates. It was also found that an evaporation rate of 0.91 × 10 −3 kg/s could be achieved for an evaporation area of 0.36 m 2 . Considering the entire desalination system, it was noted that increasing the water flow rate reduced the water temperature entering the humidifier and thus reduced production. Conversely, increasing the airflow rate enhanced the production rate. More importantly, it was shown that under appropriate conditions this novel desalination system can have a production of 10.2 litre/day/m 2 .


  • The Effect of Wind Direction on the Cooling Capacity of Short Dry Natural Draft Cooling Towers Operating in Close Proximity

    by Mehrdad Khamooshi, Timothy Anderson, Roy Nates

    The layout of multiple natural draft dry cooling towers could have a significant influence on the performance of the cooling system in concentrated solar power (CSP) plants; however, this has never been quantified. Hence, this work used computational fluid dynamics (CFD) modeling to analyze the cooling capacity of two short natural draft dry cooling towers (NDDCTs) on a common site for a range of tower spacings, wind-speeds, and wind incidence angles. The results show that the cooling performance of the towers is a strong function of tower spacing and their orientation with respect to the wind direction. It was found that when the wind came at a 90-deg wind incidence angle (i.e., normal to a line drawn between the two towers), their cooling capacity was improved at tower spacings of less than 1.8 tower diameters (1.8D), though for the other tower spacings, there was no interaction between the towers. However, with the wind at 45 deg to the towers, the flow around the towers resulted in a decrease in their cooling capacity at tower spacings of 1.8D and 2.6D. Most interestingly, it was found that orienting the towers in line with the prevailing wind direction delivered improvements in the cooling capacity of up to 30%. This is due to the windward tower acting as a passive windbreak. Hence, as CSP plant capacity is increased, and additional cooling towers are required, these should be placed close to any existing tower and oriented along the line of the prevailing winds.


  • Open Access

    The Potential for Rooftop Photovoltaic Systems in Nepal

    by Ural Kafle, Timothy Anderson, Sunil Prasad Lohani

    Nepal possesses a good solar resource, and there has been increasing interest in the use of photovoltaic systems. About 1.1 million solar home systems, rated at nearly 30 MWp, have been installed across Nepal. With the introduction of net metering by the Nepal Electricity Authority, an increase in rooftop photovoltaics (RPV) is expected. However, to inform any policy developments around increased electricity generation, and the uptake of RPV, there is a need to quantify the potential of such systems (a situation mirrored in many developing countries). To this end, this study utilized a hierarchical geospatial technique based on open-source data to estimate the potential output from RPV in several cities in Nepal (Kathmandu, Pokhara, Butwal, Nepalgunj, and Biratnagar). It was found that the potential theoretical output of RPV ranged from 637 GWh per annum, in Kathmandu, to 50 GWh per annum in Butwal. Moreover, the total RPV potential from urban households of Nepal was estimated to be in the order 6.5 TWh per annum. As such, the findings of this paper can be used to make informed policy decisions about the future of Nepal’s energy mix.


  • Reducing Energy Use in Light Industrial Buildings in Southeast Asia: A Singaporean Case Study

    by Guo Li, Timothy Anderson

    In recent years, there has been an increased interest in improving the energy efficiency of the Southeast Asian building sector. However, much of this work has focused on residential and commercial buildings rather than industrial buildings. Therefore, this work undertook a case study of the energy used in a Singaporean industrial building complex typical of those used in the light manufacturing sector in the region. A building energy simulation analysis was performed on the “as built” building and was validated using measured energy usage data. Subsequently, a parametric analysis was utilized to identify opportunities for reducing energy use on the site. The results indicate that energy savings of over 15% could be achieved by improving the performance of the industrial equipment, HVAC system, lighting, and building thermal envelope. Of these factors, improving the energy efficiency of the equipment and relaxing the HVAC setpoint temperature accounted for over 10%. Given the typical nature of the building, it is believed that the results are indicative of what may be achievable in other light manufacturing complexes in Southeast Asia, and similar locations more generally.