Assessing the Validity of Computerized Algorithms for Determining Pulse Wave Velocity: A Clinical Study
Open Access
- 1 January 2025
- journal article
- Published by S. Karger AG in Pulse
- Vol. 13 (1) , 62-71
Abstract
Introduction: Aortic stiffness, assessed through carotid-femoral pulse wave velocity (PWV), has been associated with an increased risk of cardiovascular events and mortality. Measurements of PWV are based on the proper identification of the foot of the pulse waveform by either the maximum of the second-derivative method (as used in Complior) or the intersecting tangents algorithms (as used in SphygmoCor). These approaches can give different results, especially at higher PWV ranges. However, these devices also differ by signal acquisition technology, signal filtering, and quality control algorithms, making the true contribution of analytical algorithms uncertain. The aim of the present study was to identify the differences in pulse transit time (PTT) and PWV calculated by these two algorithms when provided with the same input signal. Methods: In 113 subjects, 346 recordings of 10 s were obtained using the Complior Analyse system (PWVComp-2nd). The pulse waves were imported into MATLAB and filtered (n = 4,102 pairs of pulse waves), where after inspection 3,770 pairs were available for determination of PTT using second-derivative and intersecting tangents algorithms (PTTMat-2nd and PTTMat-IT) and the respective PWVMat-2nd and PWVMat-IT for each pair. Additionally, the same pulse wave recordings were analyzed using the SphygmoCor system in simulation mode, employing the intersecting tangents algorithm (PWVSphyg-IT). Results: The mean beat-by-beat PTTMat-2nd and PTTMat-IT were 54.55 ± 18.55 ms (range 15.00–129.00) and 54.61 ± 18.61 ms (range 15.00–126.00) (p = 0.09), respectively. The mean per participant PWVMat-2nd and PWVMat-IT were 9.67 ± 3.46 m/s and 9.66 ± 3.4 m/s with a mean difference of 0.01 ± 0.32 m/s (p = 0.35). The PWVComp-2nd and PWVSphyg-IT were 9.48 ± 3.25 m/s and 9.59 ± 3.25 m/s with a mean difference of 0.11 ± 0.66 m/s (p = 0.04). Conclusion: The present study shows that the difference between the two algorithms is negligible across a wide range of PTT and hence does not support the need for adjusting PWV according to the algorithm used for determining PTT.Keywords
This publication has 20 references indexed in Scilit:
- Estimated versus measured aortic stiffness: implications of diabetes, chronic kidney disease, sex and heightJournal Of Hypertension, 2024
- Arterial Stiffness in Hypertension and Function of Large ArteriesAmerican Journal of Hypertension, 2020
- Comparison of the Complior Analyse device with Sphygmocor and Complior SP for pulse wave velocity and central pressure assessmentJournal Of Hypertension, 2014
- Expert consensus document on the measurement of aortic stiffness in daily practice using carotid-femoral pulse wave velocityJournal Of Hypertension, 2012
- Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: ‘establishing normal and reference values’European Heart Journal, 2010
- Arterial stiffness, gender and heart rateJournal Of Hypertension, 2003
- Methods and devices for measuring arterial compliance in humansAmerican Journal of Hypertension, 2002
- Impact of Aortic Stiffness on Survival in End-Stage Renal DiseaseCirculation, 1999
- Determination of pulse wave velocities with computerized algorithmsAmerican Heart Journal, 1991
- D.-J. KORTEWEG. — Ueber die Fortpflanzungsgeschwindigkeit des Schalles in elastischen Röhren (Sur la transmission du son par les fluides renfermés dans les tubes à parois élastiques); Ann. der Physik und Chemie, t. V, p. 525; 1878Journal de Physique Théorique et Appliquée, 1880