Controlling motion artefact levels in MR images by suspending data acquisition during periods of head motion
Open Access
- 24 April 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (6) , 2415-2426
Abstract
Purpose: Head movements are a major source of MRI artefacts. Prospective motion correction techniques significantly improve data quality, but strong motion artefacts may remain in the data. We introduce a framework to suspend data acquisition during periods of head motion over a predefined threshold.Methods: Data was acquired with prospective motion correction and an external optical tracking system. A predictor of motion impact was introduced that accounts for the amplitude of the signal acquired at the time of the motion. From this predictor, a threshold was defined to trigger the suspension of data acquisition during periods of motion. The framework was tested on 5 subjects, 2 motion behaviors, and 2 head coils (20 and 64 channels).Results: The best improvements in data quality were obtained for a threshold value of 0, equivalent to suspending the acquisition based on head speed alone, at the cost of a long prolongation of scan time. For threshold values ∼3.5e−4, image quality was largely preserved, and prolongation of scan time was minimal. Artefacts occasionally remained with the 64‐channel head coil for all threshold values, seemingly due to head movement in the sharp sensitivity profile of this coil.Conclusion: The proposed suspension strategy is more efficient than relying on head speed alone. The threshold for suspension of data acquisition governs the tradeoff between image degradation due to motion and prolonged scan time, and can be tuned by the user according to the desired image quality and participant's tolerability.Keywords
All Related Versions
Funding Information
- Fondation Roger de Spoelberch
- Partridge Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (32003B_159780)
- Horizon 2020 Framework Programme (720270 (HBP SGA1))
This publication has 37 references indexed in Scilit:
- Motion correction in MRI of the brainPhysics in Medicine & Biology, 2016
- Toward Quantifying the Prevalence, Severity, and Cost Associated With Patient Motion During Clinical MR ExaminationsJournal of the American College of Radiology, 2015
- Prospective motion correction of 3D echo-planar imaging data for functional MRI using optical trackingNeuroImage, 2015
- An evaluation of prospective motion correction (PMC) for high resolution quantitative MRIFrontiers in Neuroscience, 2015
- Head motion during MRI acquisition reduces gray matter volume and thickness estimatesNeuroImage, 2015
- Spurious group differences due to head motion in a diffusion MRI studyNeuroImage, 2014
- Measurement and Correction of Microscopic Head Motion during Magnetic Resonance Imaging of the BrainPLOS ONE, 2012
- Prospective motion correction in brain imaging: A reviewMagnetic Resonance in Medicine, 2012
- Spin‐history artifact during functional MRI: Potential for adaptive correctionMedical Physics, 2011
- Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking systemNeuroImage, 2006