MCMartina F. Callaghan

Martina F. Callaghan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martina F. Callaghan has a total of 390 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modular Arrays for High Precision Wearable MEG

    by Nicholas A. Alexander, Alberto Mariola, Sahitya Puvvada, Yulia Bezsudnova, Tim M. Tierney, Gareth R. Barnes, Martina F. Callaghan

    Optically pumped magnetometers (OPMs) can be used for magnetoencephalography (MEG) with equivalent or improved signal to noise ratio, relative to cryogenic MEG, when sensors are placed close to the scalp. OPM-based MEG can also be used in mobile contexts if sensors are placed in lightweight, wearable arrays. Individually tailored, rigid helmets known as scannercasts are currently the only method capable of achieving on-scalp, mobile recordings with high precision. However, these scannercasts are expensive to produce, require structural imaging in advance of the experiment, and can incur lengthy downtime while sensors are transferred between scannercasts. Here, we introduce a solution to these challenges that retains the advantages of scannercasts. We provide detailed steps for constructing a modular, cap-based design, suitable for all head sizes. Using simulations, we compare the leadfield power of this array against an idealised array and a commercially available mobile solution. We then validate our proposed solution empirically, in five participants, and provide a complete data preparation and analysis pipeline. Our design expands the accessibility of OPM-based MEG, and increases participant throughput to levels comparable to other imaging modalities. Crucially, it removes the trade-off between signal quality, mobility and practicality, promoting the unique potential of OPM-based MEG as a tool for studying naturalistic behaviour, and clinical assessment with high precision.

  • Open Access

    Revisiting the auditory hemodynamic response function in the era of fast fMRI

    by Letitia Schneider, Isma Zulfiqar, Yaël Balbastre, Lori L. Holt, Martina F. Callaghan, Frederic Dick

    Recent advances in fast fMRI now enable whole-brain imaging with a TR of ≤1 s, which has helped to rekindle interest in characterizing the blood oxygen level dependent hemodynamic response function (BOLD HRF). Recent studies in the visual system have found intra-areal differences in temporal response characteristics, as well as HRFs that were faster and narrower than predicted by standard models. The auditory system presents a unique challenge, in that neuronal populations must operate across timescales of microseconds to minutes, and the surface of auditory cortex in particular is intricately and heavily vascularized. Here, we used fast fMRI to characterise voxelwise auditory HRFs evoked by short naturalistic sounds, assessing HRF reproducibility and variability across sessions, participants, and independent datasets. Across two studies at 3 T, participants passively listened to short environmental sounds while fMRI and quantitative MRI data were acquired with a 1s TR. Voxelwise HRFs were estimated via novel cross-session alignment routine, and exclusion of large vascular contributions. We identified a diverse set of hemodynamically plausible response shapes, which were not consistently captured by standard HRF approaches. These responses were reproducible within participants across sessions and robust across two independent acquisitions. Using data-driven gamma models, we achieved stable estimates with relatively few runs, particularly in auditory temporal regions. Within auditory cortex, we observed reproducible spatial gradients in response timing and shape, with faster and higher magnitude responses in medial regions, and slower and lower magnitude responses laterally. Together, these findings demonstrate that auditory HRFs are diverse, reliable, and regionally specific, and highlight the value of fast fMRI and data-driven modelling for advancing interpretation of fMRI data.

  • Open Access

    Reducing Motion Artifact in High Resolution 7 T MRI Using the Magnetic Resonance Minimal Motion (“MR‐MinMo”) Head Stabilization Device

    by Jyoti Mangal, Simon Richardson, Yannick Brackenier, Matthew Gardner, Pierluigi Di Cio, Chiara Casella, Shaihan Malik, Jo Hajnal, Martina F. Callaghan, Fred Dick, et al.

    Purpose: To evaluate the effectiveness of the MR‐MinMo head stabilization device in mitigating motion artifacts during long‐duration, high‐resolution 7 T MRI scans, with and without retrospective motion correction Methods: The MR‐MinMo was tested on seven pediatric and 12 adult healthy volunteers using 0.6 mm isotropic, 3D Multi‐Echo Gradient Echo (ME‐GRE) scans. A ∼10‐min ME‐GRE scan (linear sampling acceleration factor 2 × 2) and a ∼20‐min scan (DISORDER sampling acceleration factor 1.4 × 1.4) were obtained. Both scans were acquired with and without the MR‐MinMo in a 2 × 2 factorial study design. Qualitative and quantitative assessment of image quality of the first echo image was obtained via visual inspection and the normalized gradient squared (NGS) metric, respectively. A repeated measures ANOVA was used to determine individual and combined effects of the device and DISORDER images with retrospective motion correction on NGS values, with age as a binary factor (pediatric/adult). T2* maps were generated and the standard deviation of white matter R2*(=1/T2*) values assessed across conditions. Results: The MR‐MinMo significantly reduced motion artifacts both visually and in terms of NGS scores, particularly in pediatric volunteers. There was a significant interaction between MR‐MinMo and DISORDER motion correction, suggesting that MR‐MinMo improved retrospective motion correction. T2* maps demonstrated improved visual appearance and reduced WM variance with the MR‐MinMo. Conclusion: The MR‐MinMo can improve image quality via motion reduction in high‐resolution 7 T scans. By keeping motion within a correctable regime, the device can also improve the performance of retrospective motion correction methods.

  • Open Access

    Neuronal plasticity during motor rehabilitation training after spinal cord injury

    by Tim Max Emmenegger, Gergely David, Siawoosh Mohammadi, Gabriel Ziegler, Martina F. Callaghan, Alan Thompson, Karl John Friston, Nikolaus Weiskopf, Tim Killeen, Patrick Freund

    Understanding how the injured nervous system adapts to training is key to advancing rehabilitation across neurological disorders. Using spinal cord injury (SCI) as a model of severe motor-sensory disruption, we investigate whether training-induced structural plasticity in the brain is preserved despite ongoing neurodegeneration. Thirty-two healthy controls and 17 chronic SCI patients (SCI > 6 months) undergo training in a bimanual-bipedal computer-controlled motion game for one hour, four times a week, over one month, with longitudinal microstructural MRI at 3 T, including multiparameter mapping and diffusion MRI. All SCI patients exhibit performance improvements over the training period. These improvements are accompanied by spatially and temporally distributed changes in both gray and white matter, encompassing alterations in volumetric and myelin-sensitive MRI markers. SCI patients demonstrate trajectories of training-induced neuroplasticity that are comparable to, and in some cases greater than, those of healthy controls. Our findings highlight a fundamental capacity of the injured nervous system to adapt through rehabilitation, with evidence from SCI patients showing that—despite severe motor and sensory deficits—the brain can undergo learning-related structural changes. These results suggest that the mechanisms of training-induced plasticity observed in SCI may generalize to rehabilitation across a broad spectrum of neurological disorders.


  • Open Access

    A molecular map of the living human brain from quantitative MRI

    by Mina Ryten, Melissa Grant-Peters, George Thomas, Daan van Kruining, Louise Huuki-Myers, Ruth Zhang, Jonathan Brenton, Hemanth Nelvagal, Angeliki Zarkali Zarkali, James Evans, et al.

    Profiling dynamic molecular processes in neurodegeneration in vivo remains a major clinical challenge. Limited brain tissue accessibility especially limits the development and effective deployment of emerging disease modifying therapies, highlighting the need for non-invasive methods for profiling molecular disease processes. We introduce a non-invasive imaging framework that integrates ultra-high-resolution 7T quantitative MRI (qMRI) with spatially-resolved transcriptomics (SRT) to infer cell-type and pathway-specific molecular features within the cortical grey matter. We demonstrate that our method predicts from qMRI data disease-associated changes to cell type proportions and molecular pathways within the grey matter cortex which are corroborated by orthogonal datasets, including bulk RNA sequencing, single nucleus RNA sequencing and high-performance liquid chromatography. This proof-of-concept establishes the integration of qMRI and SRT as a scalable, non-invasive platform for molecular profiling in neurodegeneration, with significant potential for precision therapeutic monitoring, drug development and clinical trials.

  • Open Access

    Evidence for divergent cortical organisation in Parkinson’s disease and Lewy Body Dementia

    by Angeliki Zarkali, George Thomas, Naomi Hannaway, Ivelina Dobreva, Melissa Grant Peters, Martina F. Callaghan, Mina Ryten, Rimona S. Weil

    Dementia is a defining feature of Lewy body disease: its timing and onset distinguish different clinical diagnoses, and its effect on quality of life is profound. However, it remains unclear whether processes leading to cognitive and motor symptoms in Lewy body disease differ. To clarify this, we use in-vivo neuroimaging to assess spatial gradients of inter-regional differences in structural and functional connectivity in 108 people across the Lewy body disease spectrum (46 Parkinson’s with normal cognition (PD-NC), 62 Lewy body dementia (LBD)) and 23 controls. We show divergent structural gradient differences with cognitive impairment: PD-NC show increased inter-regional differentiation, whilst LBD show overall gradient distribution similar to controls despite widespread organisational differences at the regional level. We then assess cellular and molecular underpinnings of these organisational changes. We reveal similarities and also important differences in the drivers of cortical organisation between LBD and PD-NC, particularly in layer 4 excitatory neurons.


  • Open Access

    MORSE: Multiple Orthogonal Reference Sensitivity Encoding

    by Oliver Josephs, Barbara Dymerska, Nadine N. Graedel, Yael Balbastre, Nadege Corbin, Martina F. Callaghan

    Parallel imaging is ubiquitous in MRI, enabling diverse applications such as ultra-high-resolution functional and quantitative imaging with greater temporal resolution or reduced scan times respectively. Successful unfolding is contingent on robust and accurate estimation of the relative coil sensitivities, which often involves computation times that preclude real-time deployment. Here we present a computationally-efficient method of robustly estimating coil sensitivities, and reconstructing under-sampled images using a data-driven regularised SENSE formalism. Our MORSE scheme estimates multiple sensitivities per voxel to address issues such as rapidly varying sensitivities, chemical shift artefact, or insufficient fields of view and provides a data-driven regularisation term for noise control. Exemplar structural and functional image reconstructions at 3T and 7T are presented and compared with a vendor-provided GRAPPA reconstruction as well as state-of-the-art ESPIRiT and LORAKS algorithms. MORSE consistently produced high-quality, artefact-free images with reconstruction times feasible for real-time deployment. It is flexible and robust, and made available to the community in open-source as a library of functions within the vendor-agnostic Gadgetron image reconstruction framework.


  • Open Access

    Communication of perceptual predictions from the hippocampus to the deep layers of the parahippocampal cortex

    by Oliver Warrington, Nadine N. Graedel, Martina F. Callaghan, Peter Kok

    Current evidence suggests that the hippocampus is essential for exploiting predictive relationships during perception. However, it remains unclear whether the hippocampus drives the communication of predictions to sensory cortex or receives prediction signals from elsewhere. We collected 7-tesla fMRI data in the medial temporal lobe (MTL) while auditory cues predicted abstract shapes. Strikingly, neural patterns evoked by predicted shapes in CA2/3, pre/parasubiculum, and the parahippocampal cortex (PHC) were negatively correlated to patterns evoked by the same shapes when actually presented. Using layer-specific analyses, we ask: In which direction are predictions communicated between the hippocampus and neocortex? Superficial layers of the MTL cortex project to the hippocampus, while the deep layers receive feedback projections. Informational connectivity analyses revealed that communication between CA2/3 and PHC was specific to the deep layers of PHC. These findings suggest that the hippocampus generates predictions through pattern completion in CA2/3 and feeds these predictions back to the neocortex.


  • Open Access

    Quantitative multimodal microstructural imaging associations with chronic stroke motor impairment

    by Zeena-Britt Sanders, Melanie K Fleming, Tom Smejka, Marilien C Marzolla, Daniel Papp, Alberto Lazari, Anderson M Winkler, Emily Moore, Martina F. Callaghan, Heidi Johansen-Berg, et al.

    Background Corticospinal tract (CST) integrity, assessed using diffusion weighted MR imaging, has frequently been associated with motor impairment following stroke. However, which specific biological features contribute to this relationship remains unknown. In the current paper we used quantitative multimodal imaging to shed light on the biophysical properties underlying this relationship in the CST and explore additional whole brain relationships with motor impairment. Methods Twenty-seven chronic stroke survivors underwent MRI scanning, including multi-shell diffusion weighted imaging and quantitative Multi-Parameter Mapping, from which we derived ten metrics, sensitive to different microstructure properties. We tested the relationship between these MRI metrics and stroke survivors’ impairment scores on the Upper-Extremity Fugl Meyer (UE-FM), using multimodal and unimodal statistical inference, in both the CST and across the whole brain. Results Using an ROI approach to replicate and extend on previous findings, a joint multimodal analysis revealed that greater CST microstructure asymmetry was associated with worse motor impairment. The strongest relationships were found between impairment and several modalities sensitive to free water and myelination. This result was further confirmed using a voxel-wise approach. Beyond the CST, modalities sensitive to free water, myelination and the Neurite Density Index, were also found to be related to motor impairment, particularly in the superior longitudinal fasciculus, corpus callosum and thalamic radiations, with magnetisation transfer saturation showing the strongest relationship in these areas. Conclusion Modalities that are sensitive to myelin and free water exhibited the most significant correlation with motor impairment. This suggests that these specific biological features may account for the previously identified relationships between diffusion metrics and motor impairments. Myelin metrics in particular were also highly correlated with motor impairment in other brain regions. This study illustrates the advantages of using multimodal data to identify more specific biological factors that contribute to motor impairment in stroke patients.

  • Open Access

    Multi‐center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study

    by Eva Alonso‐Ortiz, Daniel Papp, Robert L. Barry, Kyota Poëti, Alan C. Seifert, Kyle M. Gilbert, Nibardo Lopez‐Rios, Jan Paska, Falk Eippert, Nikolaus Weiskopf, et al.

    Purpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing RF coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and currently there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils, and (2) to use that protocol to evaluate the performance of four different coil designs.Methods: Three healthy volunteers and a custom anthropomorphic phantom (the traveling spines cohort) were scanned at seven 7 T imaging centers using a common protocol and each center's specific cervical spinal cord coil. Four different coil designs were tested (two in‐house, one Rapid Biomedical, and one MRI.TOOLS design).Results: The Rapid Biomedical coil was found to have the highest efficiency, whereas one of the in‐house designs (NeuroPoly Lab) had the highest SNR and the largest spinal cord coverage. The MRI.TOOLS coil had the most uniform profile along the cervical spinal cord; however, it was limited in its ability to provide the requested flip angles (especially for larger individuals). The latter was also the case for the second in‐house coil (MSSM).Conclusion: The results of this study serve as a guide for the spinal cord MRI community in selecting the most suitable coil based on specific requirements and offer a standardized protocol for assessing future coils.