Magnetic flux leakage testing methods have been extensively used to detect defects in ferromagnetic materials. However, variations in the thickness of the surface paint layers or wax deposition can lead to unknown lift-off, which results in significant depth quantification errors. To address the challenge of quantifying the depths of internal or external defects under unknown lift-off conditions, this study introduces a new evaluation method based on time-domain features. Theoretical analysis combining the magnetic field phase reversal phenomenon and the magnetic shielding effect reveals why the rising time of the internal defect signals remains unaffected by lift-off. The simulation results verified the insensitivity of the time features to lift-off. In this experiment, a cross-correlation algorithm was used to align different datasets. Wavelet analysis was employed to extract the rising time points, and a linear regression algorithm was applied to establish a depth quantification model under varying lift-off conditions. Finally, the validation of the pipeline samples demonstrated that the depth quantification error for defects under unknown lift-off conditions did not exceed 13%.