RWRongbiao Wang

Rongbiao Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rongbiao Wang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Defect Depth Quantification Method Under Unknown Lift-Off Based on Time-Domain Magnetic Flux Leakage Signal Features

    by Rongbiao Wang, Yongzhi Chen, Xiangdong Xu, Shuanglin Guo, Zhiyuan Xu, Hongjie Shi, Yihua Kang, Keyi Yuan, Rui Dong, Junling Fan, et al.

    Magnetic flux leakage testing methods have been extensively used to detect defects in ferromagnetic materials. However, variations in the thickness of the surface paint layers or wax deposition can lead to unknown lift-off, which results in significant depth quantification errors. To address the challenge of quantifying the depths of internal or external defects under unknown lift-off conditions, this study introduces a new evaluation method based on time-domain features. Theoretical analysis combining the magnetic field phase reversal phenomenon and the magnetic shielding effect reveals why the rising time of the internal defect signals remains unaffected by lift-off. The simulation results verified the insensitivity of the time features to lift-off. In this experiment, a cross-correlation algorithm was used to align different datasets. Wavelet analysis was employed to extract the rising time points, and a linear regression algorithm was applied to establish a depth quantification model under varying lift-off conditions. Finally, the validation of the pipeline samples demonstrated that the depth quantification error for defects under unknown lift-off conditions did not exceed 13%.


  • Research on High-Temperature Eddy Current Testing Method for Tail Nozzle of Aviation Engine

    by Geng He, Kai Song, Junling Fan, Chongwen Yan, Shengbao Bai, Rongbiao Wang

    The tail nozzle of an aero-engine, made of nickel-based superalloy, is a critical component in the hot section and is prone to thermal fatigue cracks due to high temperature and high pressure. Traditional non-destructive testing (NDT) methods have limitations in high-temperature environments. This paper addresses the temperature drift issue of conventional eddy current sensors by proposing a single-excitation dual-detection symmetric U-shaped differential probe. This design suppresses temperature drift through magnetic field balancing and differential signal processing. Based on multi-physics coupling theory, a simulation model is developed to reveal the nonlinear attenuation behavior of electrical conductivity of the relevant materials in the temperature range of 20~200°C, and the correlation between defect depth and signal temperature drift. The environmental adaptability of the differential probe is confirmed to be superior. A high-temperature eddy current detection system is developed, and a platform is built for testing. Defect detection in the range of 0.3 to 1.2 mm at 20~200 °C shows that both the real and imaginary parts of the defect signal exhibit nonlinear attenuation, with deeper defects being more sensitive to temperature changes. High-temperature tests confirm that the newly developed probe effectively suppresses temperature drift in the range of 20~200 °C and performs better than traditional probes.

  • Method for Measuring the Thickness of the Cladding Oxide Film of a Nuclear Fuel Assembly Based on Eddy Current Technology

    by Qilong Lin, Lipan Zhang, Zhaoliang Wang, Hui Liu, Dongzhao Liu, Rongbiao Wang

    Accurate measurement of the thickness of the cladding oxide film of nuclear fuel assemblies is a key technical challenge to ensure the safe operation of nuclear reactors. In order to solve the problems of low efficiency, insufficient accuracy and temperature sensitivity of traditional detection methods, based on the principle of eddy current testing (ECT), the influence mechanism of temperature drift and oxide film thickness on the detection signal was studied, and a temperature compensation method combined with neural network algorithm was proposed.By constructing a three-dimensional electromagnetic field model, the parameters and detection process of eddy current probe coil were optimized. With the help of JmatPro, the conductivity of zirconium alloy, stainless steel and other materials at different temperatures is simulated, and the influence of temperature on the impedance signal is linear. The developed blade/pen-type probe adopts differential/absolute coil structure respectively, which is suitable for the narrow space inside the nuclear fuel assembly and the peripheral detection needs, combined with the ABB robotic arm to build an automated detection platform, and integrates the LabVIEW-MATLAB hybrid architecture host computer system to achieve real-time data processing. The experimental results show that the systematic measurement error is ≤3μm at room temperature, and the error is controlled within 5μm based on the Elman neural network algorithm under the unsteady temperature condition (25-90°C), which can be used for the quantitative characterization of the thickness of the cladding oxide film.

  • Research on Detection Method of Aircraft Riveting Hole Defects Based on Planar Remote Field Eddy Current

    by Jiajian Liu, Kai Song, Chen Yang, Zhaoliang Wang, Chongwen Yan, Rongbiao Wang

    To address the issues of low efficiency, strong interference signals, and insufficient sensitivity in detecting defects around aircraft rivet holes, this paper proposes a novel rapid detection sensor based on planar remote field eddy current (RFEC) technology. By employing a dual excitation coil structure with reverse winding and a multi-detection coil array design, the sensor effectively suppresses interference signals from the rivet itself while enhancing detection capability for cracks near the hole edges. COMSOL simulations and experimental validation were combined to optimize the excitation coil parameters (inner diameter of 4.5 mm, height of 3 mm, and spacing of 1 mm), significantly improving magnetic field penetration and detection sensitivity. The study reveals that as the defect length increases, the amplitude of the detection signal rises markedly while the phase remains stable. With increasing defect depth, the amplitude exhibits nonlinear attenuation, whereas the phase monotonically decreases. Variations in defect angle result in a single-peak amplitude response, with peak positions correlated to the angle. Experimental results demonstrate that the designed sensor can effectively detect defects near rivet holes with length × width × depth of 5 mm × 0.2 mm × 3 mm under the buried depth of 5 mm. This work provides theoretical and technical support for the rapid non-destructive testing (NDT) of aircraft riveted structures.

  • Research on eddy current testing method for titanium alloy bolts based on phase difference

    by Yuncheng Liu, Lipan Zhang, Qilong Lin, Weidong Zhu, Rongbiao Wang, Kai Song

    Aircraft profiled bolts, serving as critical components within the aircraft maneuvering system, are susceptible to fatigue cracks at the root of the threads during operational use, posing significant risks to both human and aircraft safety. In this study, a three-dimensional electromagnetic simulation model of bolts was established to address the challenge of distinguishing defective signals from thread signals during eddy current detection of profiled bolts. The simulation results demonstrated that utilizing a bridge differential probe sliding along the bolt axial direction with coil spacing equal to N times the thread pitch effectively suppressed thread signals, enabling accurate detection of bolt defects. Subsequent investigation revealed a strong resemblance between thread signals and lift-off signals, leading to the proposal of a novel thread noise suppression and defect identification method based on the ‘Thread-Lift-off’ signal equivalent. The method reveals the relationship between the thread signal and the defect signal so that the differential detection coil spacing does not have to be equal to N times the pitch. Subsequently, eddy current detection probes were designed and detection experiments and parameter optimization were carried out. The results show that defects at the root of the thread with a depth of 0.3 mm can be clearly detected by probes with different coil spacing, which verifies the effectiveness and reliability of the detection method.


  • Defect classification and quantification method based on AC magnetic flux leakage time domain signal characteristics

    by Rongbiao Wang, Yongzhi Chen, Haozhi Yu, Zhiyuan Xu, Jian Tang, Bo Feng, Yihua Kang, Kai Song


  • A Study of Array Remote Field Eddy Current for Hole Edge Defect Location and Evaluation of Aircraft Fasteners

    by Kai Song, Wentao Wang, Boxuan Bao, Wenyu Xie, Jinxiong Yu, Rongbiao Wang

    Hi-lock bolt fasteners are widely used in aircraft multi-layer structures, and it is especially important to detect hole edge defects of hi-lock bolt connection structures. In this study, an array remote field eddy current testing system based on FPGA(Field Programmable Gate Array) and an array remote field eddy current testing probe based on multiplexing the principle were designed and developed. Using this system, experiments were carried out on fastener test blocks, and the effects of defect length and buried depth on the detection signal were studied. The experimental results show that the defect length has a significant impact on the amplitude of the detection signal, but a small impact on the phase of the detection signal. The buried depth of a defect has a significant impact on the amplitude and phase of the defect signal. The attenuation law of the detection signal in the weak magnetic field region between channels was studied, and a rotation angle-w model was proposed. The model was used to locate the defect, and the detection signal when the defect was located directly below the coil was deduced. A method for defect evaluation using the phase and amplitude of the defect signal was proposed. It was verified that the defect location error was within 2°, and the positioning error was small, which provided a reference for the defect evaluation of array remote field eddy current.


  • A Novel Leakage Magnetic Field Enhancement Method Based on Permeability Perturbation

    by Rongbiao Wang, Jian Tang, Haozhi Yu, Bo Feng, Yihua Kang, Kai Song

    The magnetic flux leakage (MFL) testing method is widely applied in detecting ferromagnetic materials such as steel pipes. In order to protect the magnetic sensor, non-ferromagnetic wear-resistant materials are placed between the sensor and the tested workpiece by conventional MFL. However, the leakage magnetic field decays exponentially in the air, reducing the sensitivity. To improve the sensitivity of MFL, a novel approach for enhancing the leakage magnetic field based on permeability perturbation is proposed in this paper. The ferromagnetic materials are used as the medium between the sensor and the workpiece. The ferromagnetic medium generates a magnetic permeability perturbation area under the effect of the leakage magnetic field, changing the magnetic reluctance in this local area. The difference in the magnetic reluctance in the medium influences the magnetizing field, and an additional leakage magnetic field is formed which enhances the leakage magnetic field. Experiments found that the enhancement effects of different magnetic mediums with different magnetic characteristics were different. Different materials’ enhancement mechanism was analyzed by considering the saturated magnetization. Compared with conventional MFL, the method proposed in the article can increase the leakage magnetic field and improve the sensitivity of MFL.


  • Optimal design of iron-cored coil sensor in magnetic flux leakage detection of thick-walled steel pipe

    by Rongbiao Wang, Haozhi Yu, Jian Tang, Bo Feng, Yihua Kang, Kai Song

    Thick-walled steel pipes, which bear high internal pressure, are widely applied in nuclear power and pressure pipelines. If there are defects in the inner wall, they are easy to expand and cause accidents. Therefore, the thick-walled steel pipe must be subject to non-destructive testing after production. For the magnetic flux leakage (MFL) testing method, the detection sensitivity gradually decreases with the increase of wall thickness. To solve this problem, a new structure of MFL probe is proposed in this paper. The influence of the iron core permeability on the MFL signal is analyzed theoretically, and the effect of the core length and diameter on the MFL signal is analyzed by simulation. The variation of the MFL signal with the change of the iron core and coil lift-off is studied respectively. The simulation results are verified by experiments. It is found that the lift-off of the iron-cored coil is determined by the iron core position. Based on this phenomenon, an MFL array probe is designed, which can be used for online detection of thick-walled steel pipes to improve the detection sensitivity of inner wall defects.