Optimal multichannel transmission for improved cr-MREPT
Authors:
- 1 February 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (4) , 045001
Abstract
Magnetic resonance electrical properties tomography (MR-EPT), aiming at reconstructing the EP’s at radio frequencies, uses the H + field (both magnitude and phase) distribution within the object. One of the MR-EPT algorithms, cr-MREPT, accurately reconstructs the internal tissue boundaries, however, it faces an artifact which occurs at the regions where the convective field, [ ∂ H + ∂ x − i ∂ H + ∂ y , i ( ∂ H + ∂ x − i ∂ H + ∂ y ) ] T , has a low magnitude (at the noise level). This study aims to develop an artifact-free conductivity reconstruction by modifying the H + field inside the region of interest (ROI), using multiple RF transmission techniques in MRI. An eight channel multi-transmit transverse electromagnetic array is used in two different drive configurations. The first drive is the standard volume excitation configuration where all ports are driven with the same magnitude and with 45° phase increment between adjacent channels. In the second drive, the drive voltage magnitude and phases for each of the eight drive ports are modified to generate a desired H + distribution such that the low convective field region moves to another non-overlapping position. Finally, data from both drive experiments are simultaneously used to reconstruct EP’s. Computer simulations using cylindrical phantoms and a brain model are conducted and it is shown that the low convective field artifact can be eliminated. It is further shown that it is not necessary to re-calculate the port drive RF voltage magnitude and phases for each patient. The implementation issues of this method are briefly discussed.Keywords
Funding Information
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (114E522)
This publication has 30 references indexed in Scilit:
- Quantitative analysis of the reconstruction errors of the currently popular algorithm of magnetic resonance electrical property tomography at the interfaces of adjacent tissuesNMR in Biomedicine, 2016
- Gradient‐based electrical conductivity imaging usingMRphaseMagnetic Resonance in Medicine, 2016
- An Inverse Problems Approach to MR-EPT Image ReconstructionIEEE Transactions on Medical Imaging, 2015
- CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties TomographyIEEE Transactions on Medical Imaging, 2015
- Numerical methods and software tools for simulation, design, and resonant mode analysis of radio frequency birdcage coils used in MRIConcepts in Magnetic Resonance Part B, 2015
- Proposed radiofrequency phased‐array excitation scheme for homogenous and localized 7‐Tesla whole‐body imaging based on full‐wave numerical simulationsMagnetic Resonance in Medicine, 2007
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- Magnetic induction tomographyMeasurement Science and Technology, 2001
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996