  • Exact Synthesis of Hybrid Acoustic–Electromagnetic Filters With Wideband Chebyshev Responses

    by Gokhan Ariturk, Nawaf R. Almuqati, Yao Yu, Ernest Ting-Ta Yen, Adam Fruehling, Hjalti H. Sigmarsson

    Conventional synthesis methods used in the design of acoustic-wave (AW) microwave filters suffer from limited achievable fractional bandwidth (FBW) and weak out-of-band (OOB) rejection. This work presents the complete polynomial-based synthesis of a new class of hybrid acoustic–electromagnetic (hybrid-ACEM) filters to overcome both of the limitations by employing one or two electromagnetic (EM) resonators that are placed at purposefully selected locations within the design. In addition, cross-coupling mechanisms can help significantly with reducing the required electromechanical coupling coefficient in certain filter orders. Altogether, the proposed method can achieve much larger FBW values and stronger OOB rejection compared to the conventionally synthesized ladder AW filters. The effect of the finite quality factor of the EM resonators is analyzed. It is shown with the simulations that a filter for the 5g n77 band can be designed with AW resonators having $k_t^2$ values of as low as 7.3%, while the quality factor values of the EM resonators are 50. As a proof of concept, a sixth-order hybrid-ACEM prototype with a center frequency of 2.66 GHz and an FBW of 11.2% designed and fabricated using AW resonators with $k_t^2$ values of 3.5%. A comparison table shows larger achievable FBW-to- $k_t^2$ ratios compared to similar studies in the literature.


  • Open Access

    Empirical Quality Factor Prediction of Quarter-Mode Substrate Integrated Waveguide Resonators

    by Nawaf R. Almuqati, Gokhan Ariturk, Hjalti H. Sigmarsson

    Quarter-mode substrate integrated waveguide (QMSIW) is an effective technique to reduce the size of filters designed on SIW technology. An accurate prediction of the unloaded quality factor of QMSIW resonators helps to estimate the insertion loss of QMSIW filters. This article introduces new empirical equations to calculate the contribution of the finite conductor and radiation on the quality factors of QMSIW resonators. To show the accuracy of the equations, the calculated quality factor values are compared to values extracted from full-wave electromagnetic simulations for five different resonators at different frequencies and various substrate materials. For further comparison, these resonators were fabricated, and the quality factor values were extracted from measurements. The good agreement between simulations, measurements, and the predicted quality factors shows that accurate quality factor estimations can be made using the developed equations. Finally, a second-order filter is designed and fabricated to demonstrate the benefits of the proposed equations in microwave filter design.


  • Open Access

    Lossy Microwave Filters With Active Shape Correction

    by Gokhan Ariturk, Hjalti H. Sigmarsson

    Obtaining the prescribed microwave filter response is highly desirable for proper frequency selectivity in RF transceivers. As the traditional microwave filter design methods do not take into account finite unloaded quality factors, lossy resonators cause significant deviations from the prescribed filter response, especially in filters with narrow bandwidths or of high orders. This deviation gets more severe as the resonator losses increase. Building on the lossy filter design techniques by using an active shape correction mechanism, this paper proposes a new approach to recover the filter response when the filter has moderately-to-highly lossy resonators. Being different than most active filter topologies, where all of the resonators are loss-compensated, this study aims at achieving the shape correction with N - 2 active elements. To characterize the design, a novel lossy-active coupling matrix is introduced by extending the (N + 2) × (N + 2) lossy coupling matrix. The proposed theory is verified with the design and fabrication of two 3rd order 5 % bandwidth filters operating at 1 GHz and employing resonators with quality factors of 100 and 28, respectively. It has been shown that the method can recover the response in both designs and the theoretical and measured responses are in good agreement.


  • B 1 + phase retrieval for non-quadrature radio frequency excitation and its preliminary application in MR-EPT

    by Gokhan Ariturk, Yusuf Ziya Ider

    Non-quadrature radio frequency (RF) excitation has been widely studied in the fields of RF shimming, local SAR estimation, and MR-EPT with the use of multi-channel transceiver arrays. These studies generally require the retrieval of the complex transmit field ( ), which can be accomplished by acquiring its magnitude and phase in different steps. Magnitude of the transmit field is acquired with the conventional methods which give accurate results for both quadrature and non-quadrature excitations. On the other hand, there is no straightforward method to acquire the absolute phase of the transmit field and generally approximations in MRI experiments are made in order to get it. However, many of these approximations fail in non-quadrature excitation and/or in ultra high fields. In this study, we propose a simple method to acquire the absolute transmit phase in non-quadrature excitation with an eight channel transceiver TEM array for 3 T. The proposed method requires the application of a single additional quadrature drive in order to get the receive phases of the individual channels of the transceiver coil. These receive phases are then subtracted from the transceive phase of the non-quadrature drive experiment to acquire its transmit phase. The developed ideas are tested in the framework of simulations and MRI experiments with the use of four different non-quadrature drive configurations. It has been observed that the simulated and experimentally acquired transmit phase distributions tend to have a strong consensus which supports the validity of the proposed method. Finally, the estimated transmit phase distribution of non-quadrature drive is used in the standard MR-EPT study to get the conductivity reconstructions in order for the validation of its eligibility in MR-EPT studies.


  • Optimal multichannel transmission for improved cr-MREPT

    by Gokhan Ariturk, Yusuf Ziya Ider

    Magnetic resonance electrical properties tomography (MR-EPT), aiming at reconstructing the EP’s at radio frequencies, uses the H + field (both magnitude and phase) distribution within the object. One of the MR-EPT algorithms, cr-MREPT, accurately reconstructs the internal tissue boundaries, however, it faces an artifact which occurs at the regions where the convective field, [ ∂ H + ∂ x − i ∂ H + ∂ y , i ( ∂ H + ∂ x − i ∂ H + ∂ y ) ] T , has a low magnitude (at the noise level). This study aims to develop an artifact-free conductivity reconstruction by modifying the H + field inside the region of interest (ROI), using multiple RF transmission techniques in MRI. An eight channel multi-transmit transverse electromagnetic array is used in two different drive configurations. The first drive is the standard volume excitation configuration where all ports are driven with the same magnitude and with 45° phase increment between adjacent channels. In the second drive, the drive voltage magnitude and phases for each of the eight drive ports are modified to generate a desired H + distribution such that the low convective field region moves to another non-overlapping position. Finally, data from both drive experiments are simultaneously used to reconstruct EP’s. Computer simulations using cylindrical phantoms and a brain model are conducted and it is shown that the low convective field artifact can be eliminated. It is further shown that it is not necessary to re-calculate the port drive RF voltage magnitude and phases for each patient. The implementation issues of this method are briefly discussed.