Development of a Paper-Based Electrochemical Immunosensor for Cardiac Troponin I Determination Using Gold Nanoparticle-Modified Screen-Printed Electrodes
Authors:
- Mayra Asevedo Campos de ResendeMRMayra Asevedo Campos de Resende
- Ana Elisa Ferreira OliveiraAOAna Elisa Ferreira Oliveira
- Thaís Cristina de Oliveira CândidoTCThaís Cristina de Oliveira Cândido
- Daniela Nunes da SilvaDSDaniela Nunes da Silva
- Scarlat Ohanna Dávila da TrindadeSTScarlat Ohanna Dávila da Trindade
- Lucas Franco FerreiraLucas Franco Ferreira
- Arnaldo César PereiraArnaldo César Pereira
Open Access
- 31 October 2025
- journal article
- research article
- Published by MDPI AG in Chemosensors
- Vol. 13 (11) , 383
Abstract
Acute Myocardial Infarction (AMI) is a critical cardiac condition that poses a substantial threat to myocardial function. Expedient diagnosis of AMI is paramount and relies on serological assays for rapid and accurate quantification of relevant biomarkers. Electrochemical sensors have emerged as promising candidates for this application, owing to their accessibility, operational simplicity, and high specificity. In this study, we developed a paper-based electrochemical immunosensor to detect cardiac troponin I in serum and saliva specimens. The electrode was fabricated using screen-printing technology with photographic paper as the substrate, employing graphite-based ink, nail polish, and acetone as the solvent. A quasi-reference electrode was constructed using silver powder-based ink, nail polish, and acetone. The immunosensor was prepared by modifying the working electrode with gold nanoparticles (AuNP) functionalized with cardiac troponin I antibodies (anti-cTnI) and bovine serum albumin (BSA). This modified electrode was subsequently used to detect the troponin I antigen. The analyses were performed in 0.1 mol L−1 phosphate buffer medium, pH 7.00, in the presence of 5.0 mmol L−1 of the potassium ferrocyanide probe. The immunosensor exhibited a sensitivity of 0.006 µA/fg mL−1, a limit of detection of 9.83 fg mL−1, and a limit of quantification of 32.79 fg mL−1. Specificity studies conducted in the presence of other macromolecules demonstrated minimal interference, with relative standard deviations (RSD) below 5.00%, indicating a specific interaction with troponin I. Furthermore, the immunosensor demonstrated excellent reproducibility and stability. Upon application to serum and saliva samples, the immunosensor presented recoveries of approximately 99–105%, suggesting its potential applicability in clinical analyses.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de Minas Gerais (CEX—APQ-00679-22)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (468 305360/2022-1)
- INCT-DATREM (465571/2014-0)
This publication has 55 references indexed in Scilit:
- Deep Learning‐Enhanced Chemiluminescence Vertical Flow Assay for High‐Sensitivity Cardiac Troponin I TestingSmall, 2025
- Electrochemical detection of the cardiac biomarker cardiac troponin IView, 2024
- Fabrication of a Simple and Cheap Screen‐printed Silver/Silver Chloride (Ag/AgCl) Quasi‐reference ElectrodeElectroanalysis, 2021
- Antibody coated conductive polymer for the electrochemical immunosensing of Human Cardiac Troponin I in blood plasmaAnalytica Chimica Acta, 2021
- Multifunctional peptide-oligonucleotide conjugate promoted sensitive electrochemical biosensing of cardiac troponin IBiochemical Engineering Journal, 2021
- 2‐Aminotrimesic Acid‐Functionalized Graphene Oxide‐Modified Screen‐Printed Electrodes for Sensitive Electrochemical Detection of Cardiac Marker Troponin IPhysica Status Solidi (a), 2021
- Highly sensitive and selective acute myocardial infarction detection using aptamer‐tethered MoS 2 nanoflower and screen‐printed electrodesBiotechnology and Applied Biochemistry, 2020
- Paper based point of care immunosensor for the impedimetric detection of cardiac troponin I biomarkerBiomedical Microdevices, 2019
- Troponin structure and function: a view of recent progressJournal of Muscle Research and Cell Motility, 2019
- Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatographyAnalytica Chimica Acta, 2009