Full Modeling of High-Intensity Focused Ultrasound and Thermal Heating in the Kidney Using Realistic Patient Models
- 28 July 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (5) , 969-979
Abstract
Objective: High-intensity focused ultrasound (HIFU) therapy can be used for noninvasive treatment of kidney (renal) cancer, but the clinical outcomes have been variable. In this study, the efficacy of renal HIFU therapy was studied using nonlinear acoustic and thermal simulations in three patients. Methods: The acoustic simulations were conducted with and without refraction in order to investigate its effect on the shape, size, and pressure distribution at the focus. The values for the attenuation, sound speed, perfusion, and thermal conductivity of the kidney were varied over the reported ranges to determine the effect of variability on heating. Furthermore, the phase aberration was studied in order to quantify the underlying phase shifts using a second-order polynomial function. Results: The ultrasound field intensity was found to drop on average 11.1 dB with refraction and 6.4 dB without refraction. Reflection at tissue interfaces was found to result in a loss less than 0.1 dB. Focal point splitting due to refraction significantly reduced the heating efficacy. Of all the tissue parameters, perfusion was found to affect the heating the most. Small changes in temperature were seen with varying attenuation and thermal conductivity, but no visible changes were present with sound speed variations. The aberration study revealed an underlying trend in the spatial distribution of the phase shifts. Conclusion: The results show that the efficacy of HIFU therapy in the kidney could be improved with aberration correction. Significance: A method is proposed by which patient specific pretreatment calculations could be used to overcome the aberration and therefore make ultrasound treatment possible.Keywords
All Related Versions
Funding Information
- RCUK Digital Economy Programme (EP/G036861/1)
- Instrumentarium Science Foundation
- Jenny and Antti Wihuri Foundation
- Finnish Cultural Foundation
- Finnish Foundation for Technology Promotion
- EPSRC (EP/L020262/1, EP/M011119/1)
This publication has 39 references indexed in Scilit:
- Attenuation and De-focusing During High-Intensity Focused Ultrasound Therapy Through Peri-nephric FatUltrasound in Medicine & Biology, 2013
- Extracorporeal high intensity focused ultrasound for renal tumours: a 3‐year follow‐upBJU International, 2010
- Modeling power law absorption and dispersion for acoustic propagation using the fractional LaplacianThe Journal of the Acoustical Society of America, 2010
- Renal tumour size measured radiologically before surgery is an unreliable variable for predicting histopathological features: benign tumours are not necessarily smallBJU International, 2007
- RENAL CRYOABLATION: OUTCOME AT 3 YEARSJournal of Urology, 2005
- Extracorporeal ablation of renal tumours with high‐intensity focused ultrasoundBJU International, 2005
- Preliminary Experience Using High Intensity Focused Ultrasound for the Treatment of Patients With Advanced Stage Renal MalignancyJournal of Urology, 2003
- Comparative Analysis of Laparoscopic Versus Open Partial Nephrectomy for Renal Tumors in 200 PatientsJournal of Urology, 2003
- Denaturation of Collagen Via Heating: An Irreversible Rate ProcessAnnual Review of Biomedical Engineering, 2002
- Empirical relationships between acoustic parameters in human soft tissuesAcoustics Research Letters Online, 2000