The ENEA neutron personal dosimetry service
Authors:
- B. MorelliBMB. Morelli
- F. MariottiFMF. Mariotti
- E. FantuzziEFE. Fantuzzi
- 27 April 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 120 (1-4) , 312-315
Abstract
The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and 7LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of Hp(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and ‘dummy customer’ (blind test) for each issuing monitoring period) are presented and discussed.Keywords
This publication has 10 references indexed in Scilit:
- Developing a thermal neutron irradiation system for the calibration of personal dosemeters in terms of HP(10)Radiation Protection Dosimetry, 2004
- Performance of CR-39® with addition of DOP (dioctylphthalate) for fast neutron dosimetryRadiation Measurements, 2003
- Development of a reader for the routine analysis of CR-39 fast neutron dosemeters: improvement of the dosimetric performance using automatic vision and motion toolsRadiation Measurements, 2003
- CR-39 Acceptance Test and Optimisation for Fast Neutron Dosimetry ApplicationsRadiation Protection Dosimetry, 2002
- Field parameters and dosimetric characteristics of a fast neutron calibration facility: experimental and Monte Carlo evaluationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Performance Test of Dosimetric Services in the EU Member States and Switzerland for the Routine Assessment of Individual Doses (Photon, Beta and Neutron)Radiation Protection Dosimetry, 2000
- Dosimetric Performance of the Fast Neutron Dosemeter for ENEA Personal Dosimetry ServiceRadiation Protection Dosimetry, 1999
- A TL Dosemeter for Mixed Thermal Neutron and Gamma Fields Based on GR-200 and GR-207 DetectorsRadiation Protection Dosimetry, 1999
- Optimization of CR-39 for fast neutron dosimetry applicationsRadiation Measurements, 1999