BMB. Morelli

B. Morelli

*This is an algorithmically generated author record based on publicly available information.

B. Morelli has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3, )

    by F. Mariotti, E. Fantuzzi, B. Morelli, G. Gualdrini, M. C. Botta, G. Uleri, J. M. Bordy, M. Denoziere

    Recent epidemiological studies suggest a rather low-dose threshold (Hp(d), in §(136), reads that ‘… a depth d=3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, Hp(3) has rarely been monitored and Hp(0.07) can be used for the same monitoring purpose… ’. As recommended on the EU ‘Technical recommendations for monitoring individuals occupationally exposed to external radiation’, a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity Hp(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of Hp(3).


  • Personal dosimetry in terms of HP(3):Monte Carlo and experimental studies

    by P. Ferrari, G. Gualdrini, R. Bedogni, E. Fantuzzi, F. Monteventi, B. Morelli

    Hp(3) has been defined as the operational quantity for eye lens dosimetry. Hp(3)/ka conversion coefficients were evaluated at the GSF (Germany) in a 30×30×15 cm3 4-elements ICRU slab phantom for various energies and incident angles through Monte Carlo. The ISO report 12,794 suggests to employ a PMMA water filled phantom, of the same dimensions, for dosemeter calibration in terms of Hp(3). The present paper briefly summarises the main aspects of a study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical procedures for the calibration of dosemeters in terms of Hp(3). Tabulations of a new set conversion coefficients and air kerma backscatter factors are provided as a function of energy and incident angle. The paper demonstrates that a more accurate approach to the dosimetric assessment in terms of Hp(3) could be rather simply introduced employing a reduced phantom.


  • The ENEA neutron personal dosimetry service

    by B. Morelli, F. Mariotti, E. Fantuzzi

    The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and 7LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of Hp(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and ‘dummy customer’ (blind test) for each issuing monitoring period) are presented and discussed.