The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi‐automation of the existing method by using the large volume batch production system, productivity is increased 60‐fold to 188 mL while almost doubling process efficiency to 23.5%. Time‐consuming manual work such as pipetting is now supported by sensor‐based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small‐scale fluorescent hemolysis detection method.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (321130633)
This publication has 20 references indexed in Scilit:
- Flow Field of a Novel Implantable Valveless Counterpulsation Heart Assist DeviceAnnals of Biomedical Engineering, 2012
- Flow Analysis of Ventricular Assist Device Inflow and Outflow Cannula Positioning Using a Naturally Shaped Ventricle and Aortic BranchArtificial Organs, 2010
- Estimation of red cell flow in microvessels: Consequences of the Baker-Wayland spatial averaging modelMicrovascular Research, 1986
- Practical laser Doppler microscopesJournal of Physics E: Scientific Instruments, 1978
- Application of the “two-slit” photometric technique to the measurement of microvascular volumetric flow ratesMicrovascular Research, 1978
- On-line volume flow rate and velocity profile measurement for blood in microvesselsMicrovascular Research, 1974
- Preparation and properties of human erythrocyte ghostsMolecular and Cellular Biochemistry, 1973
- The effect of pH at hemolysis on the reconstitution of low cation permeability in human erythrocyte ghostsBiochimica et Biophysica Acta (BBA) - Biomembranes, 1972
- Retention of Potassium by Human Erythrocyte GhostsNature, 1960
- PERMEABILITY PROPERTIES OF ERYTHROCYTE GHOSTSJournal of General Physiology, 1952