Malte Schöps
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Malte Schöps has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Johanna Charlotte Clauser
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering University Hospital RWTH Aachen University Aachen Germany
2 shared publications Ulrich Steinseifer
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
2 shared publicationsChristian Karagiannidis
Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, ARDS and ECMO Centre, Kliniken der Stadt Köln GmbH, Witten/Herdecke University Hospital, Cologne, Germany
1 shared publication- Christian Karagiannidis
ARDS and ECMO Centre Cologne-Merheim, University Witten/Herdecke, Cologne, Germany
1 shared publication - Christopher Blum
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
1 shared publication Daniel Brodie
Center for Acute Respiratory Failure, Columbia University College of Physicians and Surgeons/NewYork-Presbyterian Hospital, New York, USA
1 shared publication
Latest Publications
- Open Access
- 28 July 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Enhancing standardized in-vitro hemolysis tests with a novel adjustable resistance
- 28 July 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessEnhancing standardized in-vitro hemolysis tests with a novel adjustable resistance
- Open Access
- 5 January 2021
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 19 (1) , 1-10
Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump
Background: Treating severe forms of the acute respiratory distress syndrome and cardiac failure, extracorporeal membrane oxygenation (ECMO) has become an established therapeutic option. Neonatal or pediatric patients receiving ECMO, and patients undergoing extracorporeal CO 2 removal (ECCO 2 R) represent low-flow applications of the technology, requiring lower blood flow than conventional ECMO. Centrifugal blood pumps as a core element of modern ECMO therapy present favorable operating characteristics in the high blood flow range (4 L/min–8 L/min). However, during low-flow applications in the range of 0.5 L/min–2 L/min, adverse events such as increased hemolysis, platelet activation and bleeding complications are reported frequently. Methods: In this study, the hemolysis of the centrifugal pump DP3 is evaluated both in vitro and in silico, comparing the low-flow operation at 1 L/min to the high-flow operation at 4 L/min. Results: Increased hemolysis occurs at low-flow, both in vitro and in silico. The in-vitro experiments present a sixfold higher relative increased hemolysis at low-flow. Compared to high-flow operation, a more than 3.5-fold increase in blood recirculation within the pump head can be observed in the low-flow range in silico. Conclusions: This study highlights the underappreciated hemolysis in centrifugal pumps within the low-flow range, i.e. during pediatric ECMO or ECCO 2 R treatment. The in-vitro results of hemolysis and the in-silico computational fluid dynamic simulations of flow paths within the pumps raise awareness about blood damage that occurs when using centrifugal pumps at low-flow operating points. These findings underline the urgent need for a specific pump optimized for low-flow treatment. Due to the inherent problems of available centrifugal pumps in the low-flow range, clinicians should use the current centrifugal pumps with caution, alternatively other pumping principles such as positive displacement pumps may be discussed in the future.
- 5 January 2021
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 19 (1) , 1-10
Open AccessHemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump
Background: Treating severe forms of the acute respiratory distress syndrome and cardiac failure, extracorporeal membrane oxygenation (ECMO) has become an established therapeutic option. Neonatal or pediatric patients receiving ECMO, and patients undergoing extracorporeal CO 2 removal (ECCO 2 R) represent low-flow applications of the technology, requiring lower blood flow than conventional ECMO. Centrifugal blood pumps as a core element of modern ECMO therapy present favorable operating characteristics in the high blood flow range (4 L/min–8 L/min). However, during low-flow applications in the range of 0.5 L/min–2 L/min, adverse events such as increased hemolysis, platelet activation and bleeding complications are reported frequently. Methods: In this study, the hemolysis of the centrifugal pump DP3 is evaluated both in vitro and in silico, comparing the low-flow operation at 1 L/min to the high-flow operation at 4 L/min. Results: Increased hemolysis occurs at low-flow, both in vitro and in silico. The in-vitro experiments present a sixfold higher relative increased hemolysis at low-flow. Compared to high-flow operation, a more than 3.5-fold increase in blood recirculation within the pump head can be observed in the low-flow range in silico. Conclusions: This study highlights the underappreciated hemolysis in centrifugal pumps within the low-flow range, i.e. during pediatric ECMO or ECCO 2 R treatment. The in-vitro results of hemolysis and the in-silico computational fluid dynamic simulations of flow paths within the pumps raise awareness about blood damage that occurs when using centrifugal pumps at low-flow operating points. These findings underline the urgent need for a specific pump optimized for low-flow treatment. Due to the inherent problems of available centrifugal pumps in the low-flow range, clinicians should use the current centrifugal pumps with caution, alternatively other pumping principles such as positive displacement pumps may be discussed in the future.
- Open Access
- 6 January 2020
- Published by Wiley in Biotechnology Journal
- Vol. 15 (4) , e1900239
Ghost Cells for Mechanical Circulatory Support In Vitro Testing: A Novel Large Volume Production
The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi‐automation of the existing method by using the large volume batch production system, productivity is increased 60‐fold to 188 mL while almost doubling process efficiency to 23.5%. Time‐consuming manual work such as pipetting is now supported by sensor‐based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small‐scale fluorescent hemolysis detection method.
- 6 January 2020
- Published by Wiley in Biotechnology Journal
- Vol. 15 (4) , e1900239
Open AccessGhost Cells for Mechanical Circulatory Support In Vitro Testing: A Novel Large Volume Production
The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi‐automation of the existing method by using the large volume batch production system, productivity is increased 60‐fold to 188 mL while almost doubling process efficiency to 23.5%. Time‐consuming manual work such as pipetting is now supported by sensor‐based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small‐scale fluorescent hemolysis detection method.