Role of Next-Generation Sequencing in Excluding the Nosocomial Origin of a Case of Legionnaires’ Disease Integrating Environmental Surveillance and Clinical Diagnosis
Authors:
- Francesco PaglioneFPFrancesco Paglione
- Cataldo Maria MannavolaCMCataldo Maria Mannavola
- Marilena La SordaMSMarilena La Sorda
- Maria Luisa RicciMaria Luisa Ricci
- Maria ScaturroMaria Scaturro
- Silvia Laura BoselloSBSilvia Laura Bosello
- Roberta MasnataRMRoberta Masnata
- Francesca Romana MonzoFMFrancesca Romana Monzo
- Sara VincentiSVSara Vincenti
- Patrizia LaurentiPLPatrizia Laurenti
- Maurizio SanguinettiMaurizio Sanguinetti
- Flavio De MaioFMFlavio De Maio
Open Access
- 17 February 2026
- journal article
- research article
- Published by MDPI AG in Microorganisms
- Vol. 14 (2) , 486
Abstract
Legionella pneumophila (Lp) remains one of the major causes of community- and hospital-acquired pneumonia, yet its diagnosis and source attribution continue to pose significant challenges. Here, we describe the case of an immunocompromised patient who developed Legionnaires’ disease during hospitalization. Following activation of the hospital’s internal surveillance system, Lp and Legionella anisa (L. anisa) were recovered from multiple water distribution points using a simplified culture-based protocol. Whole-genome sequencing (WGS) demonstrated that all environmental isolates belonged to a single clonal strain, whereas the clinical isolate was genetically unrelated, thereby excluding the hospital water system as the source of infection. Although not implicated in the patient’s disease, the detection of both Lp and L. anisa within the plumbing system highlighted underlying structural contamination and the potential masking effect of non-L. pneumophila species during culture-based surveillance. These findings support the integration of conventional microbiological methods with high-resolution genomic tools to enhance surveillance accuracy, support outbreak investigations, and strengthen public health responses. Overall, this case underscores the value of WGS as a decisive tool for source attribution, including the robust exclusion of a suspected nosocomial source, in complex clinical and environmental scenarios.Keywords
Funding Information
- MUR PNRR Extended Partnership initiative on Emerging Infectious Diseases (PE00000007, INF-ACT)
This publication has 33 references indexed in Scilit:
- Antimicrobial susceptibility and epidemiological types of Legionella pneumophila human isolates from Italy (1987–2020)Journal of Global Antimicrobial Resistance, 2025
- Lessons learned from a one-year study of Legionella spp. cultivation from activated sludge samplesJournal of Environmental Management, 2024
- Legionnaires’ Disease: Update on Diagnosis and TreatmentInfectious Diseases and Therapy, 2022
- A review of legionnaires’ disease and public water systems – Scientific considerations, uncertainties and recommendationsInternational Journal of Hygiene and Environmental Health, 2022
- Atypical pneumonia: Pathophysiology, diagnosis, and treatmentRespiratory Investigation, 2022
- Evaluation of a novel urinary antigen test kit for diagnosing Legionella pneumoniaInternational Journal of Infectious Diseases, 2021
- MOBscan: Automated Annotation of MOB Relaxases2019
- Legionnaires' diseaseThe Lancet, 2016
- Epidemiology and clinical management of Legionnaires' diseaseThe Lancet Infectious Diseases, 2014
- Pan-European Study on Culture-Proven Legionnaires' Disease: Distribution of Legionella pneumophila Serogroups and Monoclonal SubgroupsEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002