SVSara Vincenti

Sara Vincenti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sara Vincenti has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Role of Next-Generation Sequencing in Excluding the Nosocomial Origin of a Case of Legionnaires’ Disease Integrating Environmental Surveillance and Clinical Diagnosis

    by Francesco Paglione, Cataldo Maria Mannavola, Marilena La Sorda, Maria Luisa Ricci, Maria Scaturro, Silvia Laura Bosello, Roberta Masnata, Francesca Romana Monzo, Sara Vincenti, Patrizia Laurenti, et al.

    Legionella pneumophila (Lp) remains one of the major causes of community- and hospital-acquired pneumonia, yet its diagnosis and source attribution continue to pose significant challenges. Here, we describe the case of an immunocompromised patient who developed Legionnaires’ disease during hospitalization. Following activation of the hospital’s internal surveillance system, Lp and Legionella anisa (L. anisa) were recovered from multiple water distribution points using a simplified culture-based protocol. Whole-genome sequencing (WGS) demonstrated that all environmental isolates belonged to a single clonal strain, whereas the clinical isolate was genetically unrelated, thereby excluding the hospital water system as the source of infection. Although not implicated in the patient’s disease, the detection of both Lp and L. anisa within the plumbing system highlighted underlying structural contamination and the potential masking effect of non-L. pneumophila species during culture-based surveillance. These findings support the integration of conventional microbiological methods with high-resolution genomic tools to enhance surveillance accuracy, support outbreak investigations, and strengthen public health responses. Overall, this case underscores the value of WGS as a decisive tool for source attribution, including the robust exclusion of a suspected nosocomial source, in complex clinical and environmental scenarios.


  • Open Access

    An Innovative Device for the Hot Water Circuit in Hospitals to Save Energy Without Compromising the Safety and Quality of Water: Preliminary Results

    by Sara Vincenti, Mario Cesare Nurchis, Federica Boninti, Martina Sapienza, Matteo Raponi, Fabio Pattavina, Carlo Pesaro, Carlo D’alonzo, Gianfranco Damiani, Patrizia Laurenti

    Legionella colonization of water systems represents a potential hazard for humans within healthcare facilities. It is possible to contain its spread through continuous disinfection systems and the correct management and maintenance of the systems. The hygienic and sanitary quality of the water cannot be ignored in an evaluation of the management and energy costs. The Fondazione Policlinico Universitario A. Gemelli IRCCS in Rome has installed the “ME.SI. MR ACS” (MEthod of SavIngs Maximum eneRgy for hot water) device, which allows the system to activate, when necessary, avoiding continuous water recirculation. The objectives of this study are to evaluate the health and hygiene quality of the hospital water network and to evaluate the thermal and electrical energy savings and chlorine dioxide consumption, with and without this device in operation. This study involved three phases of microbiological sampling in the facility under study: ME.SI. MR ACS device installed but not running, with the boilers’ setpoint temperature at 60 °C; device running with the boilers’ setpoint temperature at 60 °C; and device in operation with the boilers’ setpoint temperature at 45 °C. The microbiological analyses were carried out in accordance with the ISO standard. The data show a constant absence of Legionella spp. in all samples. The application of ME.SI. MR ACS on the hot water recirculation circuit leads to a reduction in the daily consumption of electrical and thermal energy of 68.6% and 48.6%, respectively, for a savings of approximately EUR 23,000/year per circuit. Furthermore, with the device in operation, there is a 50% reduction in the chlorine dioxide consumption with a savings of EUR 11,500/year. ME.SI. MR ACS guarantees thermal and electrical energy savings associated with a reduction in chlorine dioxide consumption, maintaining the hygienic and sanitary quality of the water network.


  • Open Access

    Potential Use of a Combined Bacteriophage–Probiotic Sanitation System to Control Microbial Contamination and AMR in Healthcare Settings: A Pre-Post Intervention Study

    by Maria D’accolti, Irene Soffritti, Francesca Bini, Eleonora Mazziga, Luca Arnoldo, Antonella Volta, Matteo Bisi, Paola Antonioli, Patrizia Laurenti, Walter Ricciardi, et al.

    Microbial contamination in the hospital environment is a major concern for public health, since it significantly contributes to the onset of healthcare-associated infections (HAIs), which are further complicated by the alarming level of antimicrobial resistance (AMR) of HAI-associated pathogens. Chemical disinfection to control bioburden has a temporary effect and can favor the selection of resistant pathogens, as observed during the COVID-19 pandemic. Instead, probiotic-based sanitation (probiotic cleaning hygiene system, PCHS) was reported to stably abate pathogens, AMR, and HAIs. PCHS action is not rapid nor specific, being based on competitive exclusion, but the addition of lytic bacteriophages that quickly and specifically kill selected bacteria was shown to improve PCHS effectiveness. This study aimed to investigate the effect of such combined probiotic–phage sanitation (PCHSφ) in two Italian hospitals, targeting staphylococcal contamination. The results showed that PCHSφ could provide a significantly higher removal of staphylococci, including resistant strains, compared with disinfectants (−76%, p < 0.05) and PCHS alone (−50%, p < 0.05). Extraordinary sporadic chlorine disinfection appeared compatible with PCHSφ, while frequent routine chlorine usage inactivated the probiotic/phage components, preventing PCHSφ action. The collected data highlight the potential of a biological sanitation for better control of the infectious risk in healthcare facilities, without worsening pollution and AMR concerns.