Abstract
Monitoring blood coagulation in response to an anticoagulant (heparin) and its reversal agent (protamine) is essential during and after surgery, especially with cardiopulmonary bypass. A current clinical standard is the use of activated clotting time, where the mechanical movement of a plunger through a whole blood-filled channel is monitored to evaluate the endpoint time of coagulation. As a rapid, simple, low-volume, and cost-effective alternative, we have developed a paper microfluidic assay and Raspberry Pi-based device with the aim of quantifying the extent of blood coagulation in response to varying doses of heparin and protamine. The flow rate of blood through the paper microfluidic channel is automatically monitored using the Python-coded edge detection algorithm. For each set of the assay, 8-μL of fresh human whole blood (untreated and undiluted) from human subjects is loaded onto each of eight sample pads, which have been preloaded with varying amounts of heparin or protamine. The total assay time is 3-5 min including the time for sample loading and incubation.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (T32HL007955)
This publication has 18 references indexed in Scilit:
- A Brief History of Cardiopulmonary BypassSeminars in Cardiothoracic and Vascular Anesthesia, 2014
- Optical Thromboelastography to evaluate whole blood coagulationJournal of Biophotonics, 2014
- Microfluidic Devices for Blood FractionationMicromachines, 2011
- Development of a fluorescent method for detecting the onset of coagulation in human plasma on microstructured lateral flow platformsThe Analyst, 2011
- Anticoagulation and Pediatric Extracorporeal Membrane Oxygenation: Impact of Activated Clotting Time and Heparin Dose on SurvivalThe Annals of Thoracic Surgery, 2007
- Blood-on-a-ChipAnnual Review of Biomedical Engineering, 2005
- Coagulation disorders of cardiopulmonary bypass: a reviewIntensive Care Medicine, 2004
- Coagulation defects in neonates during cardiopulmonary bypassThe Annals of Thoracic Surgery, 1992
- Lack of Correlation Between Activated Clotting Time and Plasma Heparin During Cardiopulmonary BypassAnnals of Surgery, 1981
- Adequate Anticoagulation During Cardiopulmonary Bypass Determined by Activated Clotting Time and the Appearance of Fibrin MonomerThe Annals of Thoracic Surgery, 1978