Robin E. Sweeney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robin E. Sweeney has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Alouidor
Cedars-Sinai Medical Center, Los Angeles, CA, USA
1 shared publication Elizabeth Budiman
Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
1 shared publication- Jeong-Yeol Yoon
Affiliation Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona, United States of America
1 shared publication - Raymond K. Wong
Perfusion Sciences, Department of Pharmacology, College of Medicine–Tucson, The University of Arizona
1 shared publication Vina Nguyen
Perfusion Sciences Graduate Program, The University of Arizona College of Medicine, Tucson, AZ, USA
1 shared publication
Latest Publications
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (13) , 4743-4751
Flow Rate and Raspberry Pi-Based Paper Microfluidic Blood Coagulation Assay Device
Monitoring blood coagulation in response to an anticoagulant (heparin) and its reversal agent (protamine) is essential during and after surgery, especially with cardiopulmonary bypass. A current clinical standard is the use of activated clotting time, where the mechanical movement of a plunger through a whole blood-filled channel is monitored to evaluate the endpoint time of coagulation. As a rapid, simple, low-volume, and cost-effective alternative, we have developed a paper microfluidic assay and Raspberry Pi-based device with the aim of quantifying the extent of blood coagulation in response to varying doses of heparin and protamine. The flow rate of blood through the paper microfluidic channel is automatically monitored using the Python-coded edge detection algorithm. For each set of the assay, 8-μL of fresh human whole blood (untreated and undiluted) from human subjects is loaded onto each of eight sample pads, which have been preloaded with varying amounts of heparin or protamine. The total assay time is 3-5 min including the time for sample loading and incubation.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (13) , 4743-4751
Flow Rate and Raspberry Pi-Based Paper Microfluidic Blood Coagulation Assay Device
Monitoring blood coagulation in response to an anticoagulant (heparin) and its reversal agent (protamine) is essential during and after surgery, especially with cardiopulmonary bypass. A current clinical standard is the use of activated clotting time, where the mechanical movement of a plunger through a whole blood-filled channel is monitored to evaluate the endpoint time of coagulation. As a rapid, simple, low-volume, and cost-effective alternative, we have developed a paper microfluidic assay and Raspberry Pi-based device with the aim of quantifying the extent of blood coagulation in response to varying doses of heparin and protamine. The flow rate of blood through the paper microfluidic channel is automatically monitored using the Python-coded edge detection algorithm. For each set of the assay, 8-μL of fresh human whole blood (untreated and undiluted) from human subjects is loaded onto each of eight sample pads, which have been preloaded with varying amounts of heparin or protamine. The total assay time is 3-5 min including the time for sample loading and incubation.