Influence of temperature in the performance of the LED lamp

Authors:
  • EJElvo Calixto Burini Junior
    Elvo Calixto Burini Junior
  • WHWang Shu Hui Hui
    Wang Shu Hui Hui

Abstract
In this work, the temperature of LED lamp of white emission with 9 W was analyzed with or without influence of the cooling process using a fan. In this work, we analyze the temperature of the LED lamp of white emission with 9 W with or without the influence of the cooling process using a fan. The investigation was carried out by seven different methods: (1) Analysis of temperature close to LEDs inside the bulb (diffuser); (2) Analysis of temperature on LEDs without bulb; (3) Analysis of temperature on LEDs without bulb with cooling using a fan; (4) Analysis of temperature on LEDs board out of body lamp without bulb; (5) Analysis of temperature on LEDs board out of body lamp without bulb with cooling using a fan. This last analysis 5 exhibited better results, decreasing the significant temperature on the LED surface from ?130ºC (found in analysis 2) to ?45ºC. Due to good results exhibited in analysis 5, it was used in the illuminance measurements of the LED lamp without cooling in the analysis 6, and with a fan as analysis 7. Both results compared showed that using a fan had a great influence, and difference on the illuminance values by elapsed time from ?47,000 lux without a fan (analysis 6) to ?55,300 lux with fan (analysis 7), and also the use of a fan exhibited the lowest time of stabilization in 1 minute only.