Method for estimating effects of unknown correlations in spectral irradiance data on uncertainties of spectrally integrated colorimetric quantities
Authors:
- 18 July 2017
- journal article
- Published by IOP Publishing in Metrologia
- Vol. 54 (4) , 524-534
Abstract
Spectral irradiance data are often used to calculate colorimetric properties, such as color coordinates and color temperatures of light sources by integration. The spectral data may contain unknown correlations that should be accounted for in the uncertainty estimation. We propose a new method for estimating uncertainties in such cases. The method goes through all possible scenarios of deviations using Monte Carlo analysis. Varying spectral error functions are produced by combining spectral base functions, and the distorted spectra are used to calculate the colorimetric quantities. Standard deviations of the colorimetric quantities at different scenarios give uncertainties assuming no correlations, uncertainties assuming full correlation, and uncertainties for an unfavorable case of unknown correlations, which turn out to be a significant source of uncertainty. With 1% standard uncertainty in spectral irradiance, the expanded uncertainty of the correlated color temperature of a source corresponding to the CIE Standard Illuminant A may reach as high as 37.2 K in unfavorable conditions, when calculations assuming full correlation give zero uncertainty, and calculations assuming no correlations yield the expanded uncertainties of 5.6 K and 12.1 K, with wavelength steps of 1 nm and 5 nm used in spectral integrations, respectively. We also show that there is an absolute limit of 60.2 K in the error of the correlated color temperature for Standard Illuminant A when assuming 1% standard uncertainty in the spectral irradiance. A comparison of our uncorrelated uncertainties with those obtained using analytical methods by other research groups shows good agreement. We re-estimated the uncertainties for the colorimetric properties of our 1 kW photometric standard lamps using the new method. The revised uncertainty of color temperature is a factor of 2.5 higher than the uncertainty assuming no correlations.Keywords
Funding Information
- European Commission (EMRP ENV59)
This publication has 13 references indexed in Scilit:
- Uncertainty analysis of photometer quality factor f_1'Metrologia, 2008
- Uncertainties in source distribution temperature and correlated colour temperatureMetrologia, 2006
- Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nmMetrologia, 2006
- Effect of correlations in fitting spectral irradiance dataMetrologia, 2004
- Uncertainties in interpolated spectral dataJournal of Research of the National Institute of Standards and Technology, 2003
- An analytical method for estimating correlated colour temperature uncertaintyMetrologia, 2002
- Correlated colour temperature - uncertainty and estimationMetrologia, 2000
- Spectral irradiance measurements of tungsten lamps with filter radiometers in the spectral range 290 nm to 900 nmMetrologia, 2000
- New procedure for interpolating NIST FEL lamp irradiancesMetrologia, 1998
- An efficient method for generating uniformly distributed points on the surface of an n -dimensional sphereCommunications of the ACM, 1959