Abstract
Background: Single-shot echo planar imaging (SS-EPI) diffusion-weighted magnetic resonance imaging (DW-MRI) is the most-widely sequence in breast MRI. MRI artifacts and magnetic susceptibility are sometimes severe when this sequence is utilized at 3T. Purpose: To compare the imaging quality, ADC values between SS-EPI DWI sequence and two reduced field-of-view (rFOV) DWI sequences of breast cancer. Material and Methods: Twelve cases with breast cancer were scanned using SS-EPI DWI (FOV, 360 × 360 mm), rFOV DWI1 (FOV, 360 × 180 mm), and rFOV DWI2 (FOV, 280 × 140 mm), respectively. Image quality (scores 1 to 5) and ADC values of breast imaging were compared among three groups by different DWI sequences. SNR were compared between rFOV DWI1 and rFOV DWI2. Results: The imaging quality score of 12 cases was 5.00 in rFOV DWI1, 3.60 in SS-EPI DWI, and 3.75 in rFOV DWI2. The mean ADC value of 12 cases was 1.211 × 10−3 mm2/s in SS-EPI DWI, 1.107 × 10–3 mm2/s in rFOV DWI1, and 1.038 × 10–3 mm2/s in rFOV DWI2. SNR of rFOV DWI1 images was much higher than that of rFOV DWI2. Conclusion: rFOV DWI1 is the optimal DWI sequence in our study. Comparing with SS EPI DWI, suitable rFOV DWI has an obvious advantage, which can present higher image resolution and less distortion. It may be helpful in the diagnosis of breast cancer.Keywords
This publication has 25 references indexed in Scilit:
- High-resolution Diffusion-weighted Magnetic Resonance Imaging in Patients with Locally Advanced Breast CancerAcademic Radiology, 2012
- Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar ImagingAmerican Journal of Neuroradiology, 2011
- Reduced field-of-view diffusion-weighted imaging of the brain at 7 TMagnetic Resonance Imaging, 2010
- Quantitative diffusion weighted imaging for differentiation of benign and malignant breast lesions: The influence of the choice of b‐valuesJournal of Magnetic Resonance Imaging, 2010
- Assessment of Breast Lesions With Diffusion-Weighted MRI: Comparing the Use of Different b ValuesAmerican Journal of Roentgenology, 2009
- Magnetic resonance (MR) differential diagnosis of breast tumors using apparent diffusion coefficient (ADC) on 1.5‐TJournal of Magnetic Resonance Imaging, 2009
- Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imagingMagnetic Resonance in Medicine, 2007
- Artifacts and pitfalls in diffusion MRIJournal of Magnetic Resonance Imaging, 2006
- SENSE Imaging of the BreastAmerican Journal of Roentgenology, 2005
- Cardiac real-time imaging using SENSEMagnetic Resonance in Medicine, 2000