Evaluation of the correlation between dosimetric, geometric, and technical parameters of radiosurgery planning for multiple brain metastases
Open Access
- 1 July 2021
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (8) , 83-92
Abstract
Purpose: To evaluate the correlation between dosimetric, geometric, and technical parameters for radiosurgery planning of multiple brain metastasis treatments treated with a linear accelerator with volumetric modulated arc therapy (VMAT) technique.Materials and methods: Data were collected retrospectively from 55 patients who underwent radiosurgery in a single institution from August 2017 to February 2020. Patients presented 4–21 brain metastases were treated with a single fraction with doses between 18 and 20 Gy. Dosimetric variables were collected including V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, conformity index (CI), heterogeneity index (HI), maximum dose (Dmax), and the CI_R50. Geometric variables including the number of lesions, target volumes, the smallest target volume, the largest target volume, and the distance between the isocenter and the most distant lesion (DIL) and technical variables such as the numbers of total arcs, noncoplanar arcs, and isocenters were collected for analysis.Results: The number of lesions had a moderate positive correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and with the number of total arcs. The target volumes had a positive medium–high correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, and moderate positive correlation with HI, Dmax, number of arcs and noncoplanar arcs. The CI and CI_R50 had a negative correlation with all volumes related to the target: the target volumes, the smallest, and the largest lesion. A positive correlation was observed between the distance of the isocenter and the most DIL with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and the number of isocenters.Conclusion: It was found that the number of lesions and the target volumes are good predictors of dosimetric indexes of plan evaluation and that the distance between the isocenter and the most DIL harms them.Keywords
This publication has 22 references indexed in Scilit:
- Isotoxic radiosurgery planning for brain metastasesRadiotherapy and Oncology, 2016
- Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: a planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMATRadiation Oncology, 2016
- Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targetsPractical Radiation Oncology, 2016
- Optimal number of atlases and label fusion for automatic multi-atlas-based brachial plexus contouring in radiotherapy treatment planningRadiation Oncology, 2016
- Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised CoverageInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Total target volume is a better predictor of whole brain dose from gamma stereotactic radiosurgery than the number, shape, or location of the lesionsMedical Physics, 2013
- Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic RadiosurgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009
- 12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Conformity index: A reviewInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006