ACAndré Vinícius de Camargo

André Vinícius de Camargo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


André Vinícius de Camargo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unraveling the Radiobiology of Extreme Hypofractionation Doses in Head and Neck Cancer Cells In Vitro

    by Júlia Oliveira Dias, André Vinícius de Camargo, Diego da Cunha Silveira Alves da Silva, Igor Sampaio Fagundes, Izabela Natalia Faria Gomes, Laís Bueno da Silva Murra, Mariana de Cássia Bisio, Milena Giglioli, Patrik da Silva Vital, Renato José da Silva Oliveira, et al.

    Head and neck cancer (HNC) has high recurrence rates, and radiotherapy remains fundamental to treatment. Although extreme hypofractionation delivers higher doses per fraction than normofractionated regimens (≥5 Gy vs. 2 Gy/fraction), with clinical benefits shown in selected settings, its radiobiological effects in HNC are insufficiently characterized. Here, we investigated the responses of HPV-positive and HPV-negative HNC cells to 8 Gy and 2 Gy irradiation. Radiosensitivity, cell cycle redistribution, and DNA damage repair were evaluated using clonogenic and real-time proliferation assays, microscopy, and flow cytometry. HPV-positive UM-SCC-47 cells were more radiosensitive than HPV-negative 93-VU-120T cells, showing greater alterations in cell death, cellular area, G2/M accumulation, DNA double-strand breaks, and micronucleus formation, particularly after 8 Gy. Real-time proliferation assays revealed transient proliferative recovery of UM-SCC-47 during repeated 8 Gy exposure, although this was not observed to a comparable extent in other HNC cell lines. In silico analysis revealed distinct temporal transcriptional responses according to HPV status, with greater preservation of proliferation- and cell cycle-associated programs in HPV-positive cells. These findings indicate that radiation responses may differ not only in radiosensitivity but also in the trajectories of surviving cells following repeated high-dose exposure, highlighting the need to further elucidate the radiobiological mechanisms underlying extreme hypofractionation in HNC.

  • Open Access

    Evaluation of the correlation between dosimetric, geometric, and technical parameters of radiosurgery planning for multiple brain metastases

    by André Vinícius de Camargo, Minsong Cao, Diego da Cunha Silveira Alves da Silva, Raphael Leonardo Cunha de Araújo

    Purpose: To evaluate the correlation between dosimetric, geometric, and technical parameters for radiosurgery planning of multiple brain metastasis treatments treated with a linear accelerator with volumetric modulated arc therapy (VMAT) technique.Materials and methods: Data were collected retrospectively from 55 patients who underwent radiosurgery in a single institution from August 2017 to February 2020. Patients presented 4–21 brain metastases were treated with a single fraction with doses between 18 and 20 Gy. Dosimetric variables were collected including V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, conformity index (CI), heterogeneity index (HI), maximum dose (Dmax), and the CI_R50. Geometric variables including the number of lesions, target volumes, the smallest target volume, the largest target volume, and the distance between the isocenter and the most distant lesion (DIL) and technical variables such as the numbers of total arcs, noncoplanar arcs, and isocenters were collected for analysis.Results: The number of lesions had a moderate positive correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and with the number of total arcs. The target volumes had a positive medium–high correlation with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, and moderate positive correlation with HI, Dmax, number of arcs and noncoplanar arcs. The CI and CI_R50 had a negative correlation with all volumes related to the target: the target volumes, the smallest, and the largest lesion. A positive correlation was observed between the distance of the isocenter and the most DIL with V5Gy, V8Gy, V10Gy, V12Gy, V14Gy, HI, Dmax, and the number of isocenters.Conclusion: It was found that the number of lesions and the target volumes are good predictors of dosimetric indexes of plan evaluation and that the distance between the isocenter and the most DIL harms them.