Refractive and Keratometric Stability in High Myopic LASIK With High-Frequency Femtosecond and Excimer Lasers
- 1 December 2013
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 29 (12) , 832-837
Abstract
PURPOSE: To evaluate safety, efficacy, ergonomy, and refractive and keratometric stability in high myopia LASIK procedures using a novel femtosecond and excimer laser surgery platform. METHODS: One hundred sixteen eyes in consecutive cases of high myopic LASIK (⩾ −6.00 diopters [D]) with the Alcon-WaveLight FS200 femtosecond and EX500 excimer lasers (Alcon Laboratories, Fort Worth, TX) were evaluated preoperatively and postoperatively for the following parameters: refractive error, corrected distance visual acuity, uncorrected distance visual acuity, spherical equivalent correction, keratometry (with Placido topography and Scheimpflug tomography), and refractive astigmatism. Average follow-up time was 6.2 months (range: 3 to 12 months). RESULTS: Postoperative average refractive error was −0.37, −0.43, and −0.25 D for the 3-, 6-, and 12-month period, compared to −7.67 ± 1.55 D preoperatively. At 3, 6, and 12 months postoperatively 94%, 96.3%, and 100% of eyes, respectively, were within 1.0 D defocus equivalent. Postoperative refractive astigmatism was −0.21, −0.21, −0.13 D for the 3-, 6-, and 12-month period compared to −1.07 ± 1.91 D preoperatively. The proportion of eyes with postoperative astigmatism within 0.25 D was 85.3%, 81.5%, and 100%, for the 3-, 6-, and 12-month visit, respectively. Keratometric stability was within 0.22 D after the 12-month visit. There was no epithelial ingrowth or diffuse lamellar keratitis in any case. CONCLUSIONS: Clinical outcomes with this technique and technology appear to be promising in high level uncorrected visual rehabilitation of high myopia. There was small regression potential in the sample evaluated. [ J Refract Surg. 2013;29(12):832–837.]Keywords
This publication has 24 references indexed in Scilit:
- Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200)Clinical Ophthalmology, 2013
- Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel techniqueClinical Ophthalmology, 2013
- Corneal Higher Order Aberrations After LASIK for High Myopia With a Fast Repetition Rate Excimer Laser, Optimized Ablation Profile, and Femtosecond Laser–assisted FlapJournal of Refractive Surgery, 2012
- Long-term safety and efficacy follow-up of prophylactic higher fluence collagen cross-linking in high myopic laser-assisted in situ keratomileusisClinical Ophthalmology, 2012
- Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platformClinical Ophthalmology, 2012
- Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx® flex and comparison with a retrospective study of FS‐laser in situ keratomileusisActa Ophthalmologica, 2012
- Laser-Assisted In Situ Keratomileusis in High Levels of Myopia With the Amaris Excimer Laser Using Optimized Aspherical ProfilesAmerican Journal of Ophthalmology, 2011
- Wavefront-Optimized Ablation Versus Topography-Guided Customized Ablation in Myopic LASIK: Comparative Study of Higher Order AberrationsOphthalmic Surgery, Lasers and Imaging Retina, 2011
- Technical Aspects of the WaveLight FS200 Femtosecond LaserJournal of Refractive Surgery, 2010
- Regression and its mechanisms after laser in situ keratomileusis in moderate and high myopia11The authors have no proprietary interest in any of the material presented in this article.Ophthalmology, 1998