Measurement of Aortic Compliance in Abdominal Aortic Aneurysms Before and After Open and Endoluminal Repair:Preliminary Results
- 1 August 2004
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 11 (4) , 472-482
Abstract
Purpose: To assess aortic wall compliance as a portent of rupture risk in patients with abdominal aortic aneurysms. Methods: In this pilot study, 38 patients (32 men; median age 78 years, range 63–95) underwent an ultrasound scan: 20 pre-repair and 24 post-repair (18 endovascular [EVR] and 6 open). Six patients from the pre-repair group were included in a post repair study after EVR. Cine loop images were analyzed offsite using wall tracking software, which measured aortic diameter changes during cardiac cycles. Brachial blood pressure was measured, and elastic modulus (Ep) and stiffness (β) were calculated. Preop Ep and β were determined at the neck, inflection points (IP), and mid sac levels. Postop Ep and β were calculated in mid sac only for technical reasons. Results: Preoperative Ep and β were significantly higher at IP compared with neck (median Ep 24.22 versus 12.95 N/cm2, p2, p=0.001; β 17.94 versus 8.65, p=0.001. The values for IP and mid sac were Ep 24.22 versus 26.41 N/cm2, p=0.64; β 16.27 versus 17.94, p=0.64. In the postop cases (n=24), Ep and β in successful endovascular repair (n=12) were significantly higher than in open repair, respectively: median Ep 34.31 versus 12.33 N/cm2, p2, p=0.002; median β 51.52 versus 23.18, pConclusions: This pilot study shows that estimates of aortic wall compliance agree well with known values for wall stress distribution. EVR leaves patients with greater wall stiffness than those undergoing open repair, a situation accentuated by endoleaks. Wall compliance and stiffness measurement promises to be useful for the evaluation of success of endovascular repair.Keywords
This publication has 43 references indexed in Scilit:
- Endotension is Influenced by Wall Compliance in a Latex Aneurysm ModelEuropean Journal of Vascular and Endovascular Surgery, 2004
- Volume regression of abdominal aortic aneurysms and its relation to successful endoluminal exclusionJournal of Vascular Surgery, 2003
- Endotension in an experimental aneurysm modelJournal of Vascular Surgery, 2002
- Intra-aneurysm Sac Pressure – The Holy Grail of Endoluminal Grafting of AAAEuropean Journal of Vascular and Endovascular Surgery, 2002
- Rupture of an Abdominal Aortic Aneurysm Secondary to Type II EndoleakEuropean Journal of Vascular and Endovascular Surgery, 2001
- The Relationship Between Abdominal Aortic Aneurysm Distensibility and Serum Markers of Elastin and Collagen MetabolismEuropean Journal of Vascular and Endovascular Surgery, 2001
- Freedom From Endoleak After Endovascular Aneurysm Repair Does Not Equal Treatment SuccessEuropean Journal of Vascular and Endovascular Surgery, 2000
- Abdominal Aortic Aneurysm Wall Mechanics and their Relation to Risk of RuptureEuropean Journal of Vascular and Endovascular Surgery, 1999
- Mechanical properties of the aneurysmal aortaBritish Journal of Surgery, 1992
- Stiffness and elastic behavior of human intracranial and extracranial arteriesJournal of Biomechanics, 1980