MAMohan Adiseshiah

Mohan Adiseshiah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohan Adiseshiah has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Amine R. Sekhri

    Medical Imaging, The Middlesex Hospital, University College London Hospitals and University College London, England, UK

    1 shared publication
  • Anthony J. Grass

    Department of Civil Engineering, University College, London, England, UK

    1 shared publication
  • Arindam Chaudhuri

    Vascular Endovascular Unit, University College London Hospitals, University College, London, England, UK

    1 shared publication
  • Leslie E. Ansdell

    Department of Civil Engineering, University College, London, England, UK

    1 shared publication
  • Robin Richards

    Department of Medical Physics & Bioengineering, University College, London, England, UK

    1 shared publication
  • William R. Lees

    Medical Imaging, The Middlesex Hospital, University College London Hospitals and University College London, England, UK

    1 shared publication

Latest Publications

  • Measurement of Aortic Compliance in Abdominal Aortic Aneurysms Before and After Open and Endoluminal Repair:Preliminary Results

    by Amine R. Sekhri, William R. Lees, Mohan Adiseshiah

    Purpose: To assess aortic wall compliance as a portent of rupture risk in patients with abdominal aortic aneurysms. Methods: In this pilot study, 38 patients (32 men; median age 78 years, range 63–95) underwent an ultrasound scan: 20 pre-repair and 24 post-repair (18 endovascular [EVR] and 6 open). Six patients from the pre-repair group were included in a post repair study after EVR. Cine loop images were analyzed offsite using wall tracking software, which measured aortic diameter changes during cardiac cycles. Brachial blood pressure was measured, and elastic modulus (Ep) and stiffness (β) were calculated. Preop Ep and β were determined at the neck, inflection points (IP), and mid sac levels. Postop Ep and β were calculated in mid sac only for technical reasons. Results: Preoperative Ep and β were significantly higher at IP compared with neck (median Ep 24.22 versus 12.95 N/cm2, p2, p=0.001; β 17.94 versus 8.65, p=0.001. The values for IP and mid sac were Ep 24.22 versus 26.41 N/cm2, p=0.64; β 16.27 versus 17.94, p=0.64. In the postop cases (n=24), Ep and β in successful endovascular repair (n=12) were significantly higher than in open repair, respectively: median Ep 34.31 versus 12.33 N/cm2, p2, p=0.002; median β 51.52 versus 23.18, pConclusions: This pilot study shows that estimates of aortic wall compliance agree well with known values for wall stress distribution. EVR leaves patients with greater wall stiffness than those undergoing open repair, a situation accentuated by endoleaks. Wall compliance and stiffness measurement promises to be useful for the evaluation of success of endovascular repair.


  • Non-Axisymmetrical (Life-Like) Abdominal Aortic Aneurysm Models: A Do-It-Yourself Approach

    by Arindam Chaudhuri, Leslie E. Ansdell, Robin Richards, Mohan Adiseshiah, Anthony J. Grass

    Purpose: To construct life-like non-axisymmetrical abdominal aortic aneurysm models from latex. Technique: A computed tomographic 3-dimensional reconstruction of an actual abdominal aortic aneurysm was cast in plastic to provide a core for a “chemical metal” mould. The mould was then coated with nonadhesive prevulcanized dipping latex and cured to provide an idealized hollow reconstruction of the aneurysm. Conclusions: Chemical metal can be manipulated quite easily to make a mould of any required size or surface character, which then allows the manufacture of a well-matched latex model for biophysical studies of non-axisymmetrical abdominal aortic aneurysms.