Sensor and machine learning–based assessment of gap balancing in cadaveric unicompartmental knee arthroplasty surgical training
- 5 August 2021
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 45 (11) , 2843-2849
Abstract
Purpose The aim of this study was to assess the difference between flexion and extension contact forces—gap balance—after Oxford mobile-bearing medial unicompartmental knee arthroplasty (UKA) performed by surgeons with varying levels of experience. Methods Surgeons in a training programme performed UKAs on fresh frozen cadaveric specimens (n = 60). Contact force in the medial compartment of the knee was measured after UKA during extension and flexion using a force sensor, and values were clustered using an unsupervised machine learning (k-means algorithm). Univariate analysis was performed with general linear regression models to identify the explanatory variable. Results The level of experience was predictive of gap balance; surgeons were clustered into beginner, mid-level and experienced groups. Experienced surgeons’ mean difference between flexion and extension contact force was 83 N, which was significantly lower (p < 0.05) than that achieved by mid-level (215 N) or beginner (346 N) surgeons. Conclusion We found that the lowest mean difference between flexion and extension contact force after UKA was 83 N, which was achieved by surgeons with the most experience; this value can be considered the optimal value. Beginner and mid-level surgeons achieved values that were significantly lower. This study also demonstrates that machine learning can be used in combination with sensor technology for improving gap balancing judgement in UKA.Keywords
Funding Information
- National Natural Science Foundation of China (81972130,81703896,81972107,81902203;82072494)
- Beijing Municipal Science and Technology Commission, Adminitrative Commission of Zhongguancun Science Park (Z171100001017209)
- National Key Research and Development Program of China (2017YFC0108102)
- Capital Health Research and Development of Special (2020-2-4067)
This publication has 27 references indexed in Scilit:
- Can Intraoperative Sensors Determine the “Target” Ligament Balance? Early Outcomes in Total Knee ArthroplastyThe Journal of Arthroplasty, 2016
- Effect of Surgical Caseload on Revision Rate Following Total and Unicompartmental Knee ReplacementJournal of Bone and Joint Surgery, 2016
- Balancing UKA: overstuffing leads to high medial collateral ligament strainsKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplastyArchives of orthopaedic and trauma surgery, 2015
- Increased satisfaction after total knee replacement using sensor-guided technologyThe Bone & Joint Journal, 2014
- Primary TKA Patients with Quantifiably Balanced Soft-Tissue Achieve Significant Clinical Gains Sooner than Unbalanced PatientsAdvances in Orthopedics, 2014
- A New Method for Defining BalanceThe Journal of Arthroplasty, 2014
- Learning Curve With Minimally Invasive Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2010
- Effect of Calibration Method on Tekscan Sensor AccuracyJournal of Biomechanical Engineering, 2008
- Accuracy and repeatability of a new method for measuring facet loads in the lumbar spineJournal of Biomechanics, 2006