Xiaowei Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaowei Sun has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Qidong Zhang
Department of Orthopedics and Joint Surgery, China-Japan Friendship Hospital, Beijing, China
4 shared publications - Changquan Liu
China-Japan Friendship Hospital (Institute of Clinical Medical Sciences), Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
2 shared publications - Juncheng Ge
Department of Orthopaedic Surgery, Peking University China-Japan Friendship School of Clinical Medicine, Beijing, China
2 shared publications - Xiaowei Sun
Graduate School of Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
2 shared publications - Binping Ji
Department of Orthopedics, Shanxi Huajin Orthopedic Hospital, Taiyuan, China
1 shared publication - Cheng Huang
Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China
1 shared publication
Latest Publications
- 11 January 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (3) , 745-753
Gap balance difference of unicompartmental knee arthroplasty between hanging leg and supine leg position: a prospective cohort study
Purpose Gap balance is critical in Oxford unicompartmental knee arthroplasty (OUKA) surgery; the effect of lower limb positioning on gap balance judgements has not been reported. There are two mean operative positions for OUKA patients, the hanging leg (HL) and the supine leg (SL) position. This study aimed to investigate the gap balance achieved by current UKA surgical techniques by using a force sensor, to compare the differences in gap balance between the two different positions, and to test whether the difference in gap balance leads to different outcomes in terms of component alignment and early post-operative clinical outcomes. Methods This prospective study included 97 knees (76 patients), who underwent OUKA from June 1, 2020, to July 31, 2021, of which 67 knees underwent UKA in the supine leg position and the other 30 in the hanging leg position. When the operator was satisfied with the gap balance, the contact forces between the trial and the spacer block were measured at 90° of knee flexion (flexion gap) and 20° of knee flexion (extension gap) using a pre-developed matrix flexible force sensor. X-rays were reviewed three to five days after surgery. Knee Society Scores (KSS) were obtained at the six month follow-up. Results Compared to the HL group, the contact force at the flexion gap was higher in the SL group: 55.15N (SD 43.36N) vs. 34.25N (SD 27.56N) (p < 0.05), whereas in the extension gap, there was no significant difference, 90.19 N (SD 43.36N) in the SL group and 86.72N (SD 43.08N) in the HL group (ns.). The contact force was greater in the extension gap than in the flexion gap in both groups (p < 0.01). The gap balance difference in the HL group was 52.46N (SD 31.33N), which was greater than that of the SL group at 35.03N (SD 19.50N) (p < 0.05). There were no significant differences in component alignment or lower limb mechanical alignment between the two groups. There was no significant difference in pre-operative and post-operative KSS between the two groups, while post-operative KSS was significantly higher in both groups compared to the pre-operative period. Conclusion The intra-operative contact forces between the flexion and extension gaps differed in the two groups; the hanging leg position appeared to produce a greater difference in the judgement of gap balance than the supine leg position, but this difference did not adversely affect the alignment of the component or the early post-operative clinical outcome.
- 11 January 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (3) , 745-753
Gap balance difference of unicompartmental knee arthroplasty between hanging leg and supine leg position: a prospective cohort study
Purpose Gap balance is critical in Oxford unicompartmental knee arthroplasty (OUKA) surgery; the effect of lower limb positioning on gap balance judgements has not been reported. There are two mean operative positions for OUKA patients, the hanging leg (HL) and the supine leg (SL) position. This study aimed to investigate the gap balance achieved by current UKA surgical techniques by using a force sensor, to compare the differences in gap balance between the two different positions, and to test whether the difference in gap balance leads to different outcomes in terms of component alignment and early post-operative clinical outcomes. Methods This prospective study included 97 knees (76 patients), who underwent OUKA from June 1, 2020, to July 31, 2021, of which 67 knees underwent UKA in the supine leg position and the other 30 in the hanging leg position. When the operator was satisfied with the gap balance, the contact forces between the trial and the spacer block were measured at 90° of knee flexion (flexion gap) and 20° of knee flexion (extension gap) using a pre-developed matrix flexible force sensor. X-rays were reviewed three to five days after surgery. Knee Society Scores (KSS) were obtained at the six month follow-up. Results Compared to the HL group, the contact force at the flexion gap was higher in the SL group: 55.15N (SD 43.36N) vs. 34.25N (SD 27.56N) (p < 0.05), whereas in the extension gap, there was no significant difference, 90.19 N (SD 43.36N) in the SL group and 86.72N (SD 43.08N) in the HL group (ns.). The contact force was greater in the extension gap than in the flexion gap in both groups (p < 0.01). The gap balance difference in the HL group was 52.46N (SD 31.33N), which was greater than that of the SL group at 35.03N (SD 19.50N) (p < 0.05). There were no significant differences in component alignment or lower limb mechanical alignment between the two groups. There was no significant difference in pre-operative and post-operative KSS between the two groups, while post-operative KSS was significantly higher in both groups compared to the pre-operative period. Conclusion The intra-operative contact forces between the flexion and extension gaps differed in the two groups; the hanging leg position appeared to produce a greater difference in the judgement of gap balance than the supine leg position, but this difference did not adversely affect the alignment of the component or the early post-operative clinical outcome.
- 28 October 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (7) , 4349-4361
Coronal tibiofemoral subluxation under valgus stress force radiography is useful for evaluating postoperative coronal tibiofemoral subluxation in mobile-bearing UKA
Purpose Coronal tibiofemoral subluxation (CTFS) is considered a controversial and potential contraindication to unicompartmental knee arthroplasty (UKA) but is less discussed. The study aims to observe the CTFS in a cohort of patients before and after mobile-bearing UKA and to investigate the relationship between preoperative variables (preoperative CTFS and preoperative CTFS under valgus stress) and postoperative CTFS after mobile-bearing UKA. Methods The study retrospectively analyzed 181 patients (224 knees) undergoing mobile-bearing UKA from September 1 2019 to December 31 2021. By using hip-to-ankle anterior–posterior (AP) standing radiographs and valgus stress force radiographs, preoperative CTFS, preoperative CTFS under valgus stress, and postoperative CTFS were measured. CTFS was defined as the distance between the tangent line to the outermost joint edge of the lateral condyle of the femur and the tangent line of the lateral tibial plateau. All patients were divided into two groups based on postoperative CTFS, group A (postoperative CTFS ≤ 5 mm) and group B (postoperative CTFS > 5 mm). The Student’s t-test, one-way ANOVA together with Tukey’s post hoc test, the chi-square test, the Fisher’s exact test, Pearson correlation analysis, simple and multiple linear regression, and univariate and multiple logistic regression were used in the analyses. Results The means ± standard deviations (SD) of preoperative CTFS, preoperative CTFS under valgus stress, and postoperative CTFS were 4.96 ± 1.82 mm, 3.06 ± 1.37 mm, and 3.19 ± 1.27 mm. The difference between preoperative CTFS and postoperative CTFS was statistically significant (p < 0.001). The preoperative CTFS (6.35 ± 1.34 mm) in Group B (n = 22) was significantly higher than that (4.81 ± 1.82 mm) in Group A (n = 202) (p < 0.001), so was the variable-preoperative CTFS under valgus stress (5.41 ± 1.00 mm (Group B) > 2.80 ± 1.14 mm (Group A), p < 0.001). In Pearson correlation analysis, there was a correlation between preoperative CTFS and postoperative CTFS (r = 0.493, p < 0.001), while the correlation between preoperative CTFS under valgus stress and postoperative CTFS was stronger (r = 0.842, p < 0.001). In multiple linear regression analysis, preoperative CTFS under valgus stress (β = 0.798, 95% confidence interval (CI) = 0.714–0.883, p < 0.001) was significantly correlated with postoperative CTFS. In multiple logistic regression analysis, preoperative CTFS under valgus stress (OR = 12.412, 95% CI = 4.757–32.384, and p < 0.001) was expressed as the risk factor of postoperative CTFS (> 5 mm). Conclusion Preoperative CTFS can be improved significantly after mobile-bearing UKA. In addition, postoperative CTFS is correlated with preoperative CTFS under valgus stress and a higher preoperative CTFS under valgus stress will increase the risk of higher postoperative CTFS (> 5 mm). Level of evidence Level III.
- 28 October 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (7) , 4349-4361
Coronal tibiofemoral subluxation under valgus stress force radiography is useful for evaluating postoperative coronal tibiofemoral subluxation in mobile-bearing UKA
Purpose Coronal tibiofemoral subluxation (CTFS) is considered a controversial and potential contraindication to unicompartmental knee arthroplasty (UKA) but is less discussed. The study aims to observe the CTFS in a cohort of patients before and after mobile-bearing UKA and to investigate the relationship between preoperative variables (preoperative CTFS and preoperative CTFS under valgus stress) and postoperative CTFS after mobile-bearing UKA. Methods The study retrospectively analyzed 181 patients (224 knees) undergoing mobile-bearing UKA from September 1 2019 to December 31 2021. By using hip-to-ankle anterior–posterior (AP) standing radiographs and valgus stress force radiographs, preoperative CTFS, preoperative CTFS under valgus stress, and postoperative CTFS were measured. CTFS was defined as the distance between the tangent line to the outermost joint edge of the lateral condyle of the femur and the tangent line of the lateral tibial plateau. All patients were divided into two groups based on postoperative CTFS, group A (postoperative CTFS ≤ 5 mm) and group B (postoperative CTFS > 5 mm). The Student’s t-test, one-way ANOVA together with Tukey’s post hoc test, the chi-square test, the Fisher’s exact test, Pearson correlation analysis, simple and multiple linear regression, and univariate and multiple logistic regression were used in the analyses. Results The means ± standard deviations (SD) of preoperative CTFS, preoperative CTFS under valgus stress, and postoperative CTFS were 4.96 ± 1.82 mm, 3.06 ± 1.37 mm, and 3.19 ± 1.27 mm. The difference between preoperative CTFS and postoperative CTFS was statistically significant (p < 0.001). The preoperative CTFS (6.35 ± 1.34 mm) in Group B (n = 22) was significantly higher than that (4.81 ± 1.82 mm) in Group A (n = 202) (p < 0.001), so was the variable-preoperative CTFS under valgus stress (5.41 ± 1.00 mm (Group B) > 2.80 ± 1.14 mm (Group A), p < 0.001). In Pearson correlation analysis, there was a correlation between preoperative CTFS and postoperative CTFS (r = 0.493, p < 0.001), while the correlation between preoperative CTFS under valgus stress and postoperative CTFS was stronger (r = 0.842, p < 0.001). In multiple linear regression analysis, preoperative CTFS under valgus stress (β = 0.798, 95% confidence interval (CI) = 0.714–0.883, p < 0.001) was significantly correlated with postoperative CTFS. In multiple logistic regression analysis, preoperative CTFS under valgus stress (OR = 12.412, 95% CI = 4.757–32.384, and p < 0.001) was expressed as the risk factor of postoperative CTFS (> 5 mm). Conclusion Preoperative CTFS can be improved significantly after mobile-bearing UKA. In addition, postoperative CTFS is correlated with preoperative CTFS under valgus stress and a higher preoperative CTFS under valgus stress will increase the risk of higher postoperative CTFS (> 5 mm). Level of evidence Level III.
- 5 August 2021
- Published by Springer Nature in International Orthopaedics
- Vol. 45 (11) , 2843-2849
Sensor and machine learning–based assessment of gap balancing in cadaveric unicompartmental knee arthroplasty surgical training
Purpose The aim of this study was to assess the difference between flexion and extension contact forces—gap balance—after Oxford mobile-bearing medial unicompartmental knee arthroplasty (UKA) performed by surgeons with varying levels of experience. Methods Surgeons in a training programme performed UKAs on fresh frozen cadaveric specimens (n = 60). Contact force in the medial compartment of the knee was measured after UKA during extension and flexion using a force sensor, and values were clustered using an unsupervised machine learning (k-means algorithm). Univariate analysis was performed with general linear regression models to identify the explanatory variable. Results The level of experience was predictive of gap balance; surgeons were clustered into beginner, mid-level and experienced groups. Experienced surgeons’ mean difference between flexion and extension contact force was 83 N, which was significantly lower (p < 0.05) than that achieved by mid-level (215 N) or beginner (346 N) surgeons. Conclusion We found that the lowest mean difference between flexion and extension contact force after UKA was 83 N, which was achieved by surgeons with the most experience; this value can be considered the optimal value. Beginner and mid-level surgeons achieved values that were significantly lower. This study also demonstrates that machine learning can be used in combination with sensor technology for improving gap balancing judgement in UKA.
- 5 August 2021
- Published by Springer Nature in International Orthopaedics
- Vol. 45 (11) , 2843-2849
Sensor and machine learning–based assessment of gap balancing in cadaveric unicompartmental knee arthroplasty surgical training
Purpose The aim of this study was to assess the difference between flexion and extension contact forces—gap balance—after Oxford mobile-bearing medial unicompartmental knee arthroplasty (UKA) performed by surgeons with varying levels of experience. Methods Surgeons in a training programme performed UKAs on fresh frozen cadaveric specimens (n = 60). Contact force in the medial compartment of the knee was measured after UKA during extension and flexion using a force sensor, and values were clustered using an unsupervised machine learning (k-means algorithm). Univariate analysis was performed with general linear regression models to identify the explanatory variable. Results The level of experience was predictive of gap balance; surgeons were clustered into beginner, mid-level and experienced groups. Experienced surgeons’ mean difference between flexion and extension contact force was 83 N, which was significantly lower (p < 0.05) than that achieved by mid-level (215 N) or beginner (346 N) surgeons. Conclusion We found that the lowest mean difference between flexion and extension contact force after UKA was 83 N, which was achieved by surgeons with the most experience; this value can be considered the optimal value. Beginner and mid-level surgeons achieved values that were significantly lower. This study also demonstrates that machine learning can be used in combination with sensor technology for improving gap balancing judgement in UKA.
- Open Access
- 7 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-11
Does new instrument for Oxford unicompartmental knee arthroplasty improve short-term clinical outcome and component alignment? A meta-analysis
Background: The Microplasty (MP) instrumentation designed for the Phase III Oxford mobile-bearing unicompartmental knee arthroplasty (UKA) system is considered a better option to achieve more accurate component positioning and alignment. In the present study, we focused on short-term clinical and radiological outcomes to determine whether the MP instrumentation can reduce the short-term revision rate and occurrence of outliers of metallic components. Methods: The literature in PubMed, Embase, the Cochrane Library, and Web of Science was searched up to May 2020. Studies were scrutinized by two independent authors, and the revision rate, complication spectrum, and radiological assessment with outlier rates were specifically analyzed. RevMan 5.3 was used for the statistical analysis. Results: Seven studies were included in the meta-analysis. Four studies reported both clinical and radiological outcomes, two reported only radiological outcomes, and one reported only clinical outcomes. The pooled analysis showed that the revision rate in the MP instrumentation group was 0.866 per 100 component years, while that in the control group was 1.124 (odds ratio, 0.77; p < 0.05). The subgroup analysis of the bearing dislocation rate showed a significantly greater reduction in the Korean population than in the populations of other countries (p < 0.05). The radiological assessment showed that the alignment of the femoral component was significantly improved (p < 0.05), while that of the tibial component was not (p > 0.05). Conclusion: The newly developed MP instrumentation for Oxford UKA significantly reduced the revision rate of this treatment. The positioning of the femoral component was also proven to be better by radiological assessments.
- 7 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-11
Open AccessDoes new instrument for Oxford unicompartmental knee arthroplasty improve short-term clinical outcome and component alignment? A meta-analysis
Background: The Microplasty (MP) instrumentation designed for the Phase III Oxford mobile-bearing unicompartmental knee arthroplasty (UKA) system is considered a better option to achieve more accurate component positioning and alignment. In the present study, we focused on short-term clinical and radiological outcomes to determine whether the MP instrumentation can reduce the short-term revision rate and occurrence of outliers of metallic components. Methods: The literature in PubMed, Embase, the Cochrane Library, and Web of Science was searched up to May 2020. Studies were scrutinized by two independent authors, and the revision rate, complication spectrum, and radiological assessment with outlier rates were specifically analyzed. RevMan 5.3 was used for the statistical analysis. Results: Seven studies were included in the meta-analysis. Four studies reported both clinical and radiological outcomes, two reported only radiological outcomes, and one reported only clinical outcomes. The pooled analysis showed that the revision rate in the MP instrumentation group was 0.866 per 100 component years, while that in the control group was 1.124 (odds ratio, 0.77; p < 0.05). The subgroup analysis of the bearing dislocation rate showed a significantly greater reduction in the Korean population than in the populations of other countries (p < 0.05). The radiological assessment showed that the alignment of the femoral component was significantly improved (p < 0.05), while that of the tibial component was not (p > 0.05). Conclusion: The newly developed MP instrumentation for Oxford UKA significantly reduced the revision rate of this treatment. The positioning of the femoral component was also proven to be better by radiological assessments.