Single‐center prospective study examining use of the Wattson temporary pacing guidewire for transcatheter aortic valve replacement
- 9 March 2020
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (4) , 968-971
Abstract
Objectives: To assess the safety and efficacy of the Wattson temporary pacing guidewire.Background: Transcatheter aortic valve replacement (TAVR) requires a guidewire for device delivery and generally requires temporary pacing wire for burst and back‐up pacing. The Wattson wire provides concomitant support and bipolar pacing without the need to place a temporary venous pacemaker (TVP).Methods: This was a single‐center nonrandomized prospective clinical trial enrolling 20 patients. The primary endpoint was defined as successful rapid pacing and transcatheter heart valve (THV) delivery with no loss of capture. Safety, qualitative and quantitative secondary outcomes were also analyzed.Results: Mean age was 77.4 ± 9.0 years. Mean Society of Thoracic Surgery (STS) score was 3.0 ± 1.5%. All patients received a balloon‐expandable valve via a transfemoral approach. All patients met the primary end‐point. One patient (5%) had balloon predilatation and six patients (30%) had postdilatation, all using the wire. Mean pacing threshold was 2.2 ± 1.2 mA that was evaluated prior to placing an insulating catheter over the wire. One patient required TVP placement and subsequent permanent pacemaker implantation due to complete heart block post THV deployment. There were no incidences of cardiac perforation or tamponade. One patient required valve reintervention, which was not related to the device.Conclusions: The Wattson wire offered predictable guidewire support with concomitant reliable bipolar pacing at low thresholds to allow safe THV delivery in this patient cohort. It has the potential to make TAVR a safer and more efficient procedure.Keywords
Funding Information
- Arrow International Inc., a subsidiary of Teleflex Inc.
This publication has 8 references indexed in Scilit:
- Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2019
- Early experience with a purpose-designed temporary pacing guidewire for transcatheter valve implantationEuroIntervention, 2019
- The Vancouver 3M (Multidisciplinary, Multimodality, But Minimalist) Clinical Pathway Facilitates Safe Next-Day Discharge Home at Low-, Medium-, and High-Volume Transfemoral Transcatheter Aortic Valve Replacement CentersJACC: Cardiovascular Interventions, 2019
- Transcatheter aortic valve implantation (TAVI) in Germany: more than 100,000 procedures and now the standard of care for the elderlyEuroIntervention, 2019
- Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic reviewEuropean Heart Journal, 2018
- Rapid pacing using the 0.035‐in. Retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplastyCatheterization and Cardiovascular Interventions, 2016
- Rapid pacing using the left ventricular guidewire: Reviving an old technique to simplify BAV and TAVI proceduresCatheterization and Cardiovascular Interventions, 2016
- Predictors of Permanent Pacemaker Implantation in Patients With Severe Aortic Stenosis Undergoing TAVRJACC, 2014