An Evaluation of a PTT-Based Method for Noninvasive and Cuffless Estimation of Arterial Blood Pressure
Authors:
- 1 August 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 6049-6052
Abstract
The aim of this study is to determine if a noninvasive and cuffless blood pressure (BP) estimation method using pulse transit time (PTT) can accurately track the changes in BP after a treadmill exercise. Experiments were conducted on 12 healthy subjects, who were directed to run on a treadmill at 10 kph for 4 minutes. For each subject, 13 trials were recorded in total, including 11 trials obtained immediately after exercise and during the 60-minute recovery period. BP was measured at the finger by the Finometer and at the brachial arteries by a sphygmomanometer respectively. PTT was determined as the time interval between the peak of the electrocardiogram R wave and the foot of the photoplethysmogram. Both PTT-based device and Finometer were calibrated initially and Finometer calibration was also performed after exercise to the sphygmomanometer. Experimental results showed that there was only occasional discrepancy between BPs measured by Finometer and PTT-based device during the recovery period, i.e., at 5 minutes after exercise (p=0.008 for systolic BP and p=0.03 for diastolic BP). At all other post exercise time spots there were no significant differences between BPs measured by Finometer and PTT-based deviceKeywords
This publication has 12 references indexed in Scilit:
- Continuous noninvasive blood pressure measurement by pulse transit time2007
- Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time2005
- Arterial distensibility: acute changes following dynamic exercise in normal subjectsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2003
- Use of radial arterial tonometric continuous blood pressure measurement in cardiovascular reactivity studiesBlood Pressure Monitoring, 2002
- Accuracy and precision of blood pressure determination with the Finapres: an overview using re-sampling statisticsJournal of Human Hypertension, 1998
- Fifteen years experience with finger arterial pressure monitoring: assessment of the technologyCardiovascular Research, 1998
- Postexercise hypotension. Key features, mechanisms, and clinical significance.Hypertension, 1993
- Accuracy of a continuous blood pressure monitor based on arterial tonometry.Hypertension, 1993
- COMPARISON OF THE FINAPRES AND DIRECT ARTERIAL PRESSURE MONITORING DURING PROFOUND HYPOTENSIVE ANAESTHESIABritish Journal of Anaesthesia, 1991
- Short-term effect of dynamic exercise on arterial blood pressure.Circulation, 1991