Semiparametric Identification of Human Arm Dynamics for Flexible Control of a Functional Electrical Stimulation Neuroprosthesis
- 29 February 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 24 (12) , 1405-1415
Abstract
We present a method to identify the dynamics of a human arm controlled by an implanted functional electrical stimulation neuroprosthesis. The method uses Gaussian process regression to predict shoulder and elbow torques given the shoulder and elbow joint positions and velocities and the electrical stimulation inputs to muscles. We compare the accuracy of torque predictions of nonparametric, semiparametric, and parametric model types. The most accurate of the three model types is a semiparametric Gaussian process model that combines the flexibility of a black box function approximator with the generalization power of a parameterized model. The semiparametric model predicted torques during stimulation of multiple muscles with errors less than 20% of the total muscle torque and passive torque needed to drive the arm. The identified model allows us to define an arbitrary reaching trajectory and approximately determine the muscle stimulations required to drive the arm along that trajectory.Keywords
Funding Information
- Cleveland State University (Graduate Faculty Travel Grant)
- Directorate for Computer and Information Science and Engineering (0932263)
- Division of Civil Mechanical and Manufacturing Innovation (DGE-0824162)
- National Institute of Neurological Disorders and Stroke (N01-NS-5-2365)
This publication has 29 references indexed in Scilit:
- Combined feedforward and feedback control of a redundant, nonlinear, dynamic musculoskeletal systemMedical & Biological Engineering & Computing, 2009
- Motion control of musculoskeletal systems with redundancyBiological Cybernetics, 2008
- Functional electrical stimulation after spinal cord injury: current use, therapeutic effects and future directionsSpinal Cord, 2007
- Neuromuscular electrical stimulation in neurorehabilitationMuscle & Nerve, 2007
- Functional Electrical Stimulation for Neuromuscular ApplicationsAnnual Review of Biomedical Engineering, 2005
- Sliding Mode Closed-Loop Control of FES: Controlling the Shank MovementIEEE Transactions on Biomedical Engineering, 2004
- Hill muscle model errors during movement are greatest within the physiologically relevant range of motor unit firing ratesJournal of Biomechanics, 2003
- An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscleIEEE Transactions on Biomedical Engineering, 1998
- A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation systemIEEE Transactions on Rehabilitation Engineering, 1994
- Methods for estimating isometric recruitment curves of electrically stimulated muscleIEEE Transactions on Biomedical Engineering, 1989