Improving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer′s Disease Studies
Open Access
- 1 July 2015
- journal article
- research article
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 14 (03) , 171-177
Abstract
The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering.Keywords
This publication has 17 references indexed in Scilit:
- PET Image Denoising Using a Synergistic Multiresolution Analysis of Structural (MRI/CT) and Functional DatasetsJournal of Nuclear Medicine, 2008
- Molecular Neuroimaging: From Conventional to Emerging TechniquesRadiology, 2007
- Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PETNeuroImage, 2006
- Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.2006
- Prediction of individual clinical outcome in MCI by means of genetic assessment and (18)F-FDG PET.2005
- Improving 3D PET imaging by restoration: a phantom studyComputerized Medical Imaging and Graphics, 2005
- Deconvolution by thresholding in mirror wavelet basesIEEE Transactions on Image Processing, 2003
- Discrimination between Alzheimer Dementia and Controls by Automated Analysis of Multicenter FDG PETNeuroImage, 2002
- A JAVA environment for medical image data analysis: Initial application for brain PET quantitationMedical Informatics, 1998
- DIGITAL RESTORATION OF IN-111 AND I-123 SPECT IMAGES WITH OPTIMIZED METZ FILTERS1986