Karin Knešaurek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Karin Knešaurek has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Josef Machac
Division of Nuclear Medicine, Box 1141, One Gustave L. Levy Place, The Mount Sinai Medical Center, New York 10029, USA
4 shared publications- Josef Machac
Nuclear Medicine, Mount Sinai Medical Center, Icahn School of Medicine at Mount Sinai, Box 1141, 1 Gustave Levy Place, New York, NY 10029, USA
3 shared publications Lale Kostakoglu
Division of Nuclear Medicine, Icahn School of Medicine at Mount Sinai, New York, USA; Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
3 shared publicationsSherif Heiba
Division of Nuclear Medicine, Icahn School of Medicine at Mount Sinai, New York, USA; Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
3 shared publicationsAbbas Tuli
Division of Nuclear Medicine, Icahn School of Medicine at Mount Sinai, New York, USA; Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
2 shared publicationsAllen Gribetz
The Mount Sinai Hospital
1 shared publication
Latest Publications
- 26 November 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1129) , 20210294
Tumour-to-normal tissue (T/N) dosimetry ratios role in assessment of 90Y selective internal radiation therapy (SIRT)
Objective: The purpose of our work is to assess the role of tumour-to-normal tissue (T/N) dosimetry ratios for predicting response in patients undergoing locoregional therapy to the liver with 90Y microspheres. Methods: A total of 39 patients (7 female:32 male, mean age 68.3 ± 7.6 years), underwent positron emission tomography (PET)/CT imaging after treatment with 90Y microspheres. For attenuation correction and localization of the 90Y microspheres, the low-dose, non-diagnostic CT images from PET/CT were used. The acquisition took 15 min and the reconstruction matrix size was 200 × 200 × 75 mm and voxel size of 4.07 × 4.07 × 3.00 mm. For dosimetry calculations, the local deposition method with known activity of 90Y was used. For each patient, regions of interest for tumour(s) and whole liver were manually created; the normal tissue region of interest was created automatically. mRECIST criteria on MRI done at 1 month post-treatment and subsequently every 3 months after 90Y treatment, were used to assess response. Results: For 39 patients, the mean liver, tumour and normal tissue doses (mean ± SD) were, 55.17 ± 26.04 Gy, 911.87 ± 866.54 Gy and 47.79 ± 20.47 Gy, respectively. Among these patients, 31 (79%) showed complete response (CR) and 8 (21%) showed progression of disease (PD). For patients with CR, the mean T/N dose ratio obtained was 24.91 (range 3.09–80.12) and for patients with PD, the mean T/N dose ratio was significantly lower, at 6.69 (range 0.36–14.75). Conclusion: Our data show that patients with CR have a statistically higher T/N dose ratio than those with PD. Because, the number of PD cases was limited and partial volume effect was not considered, further investigation is warranted. Advances in knowledge: T/N dosimetry ratios can be used for assessing response in patients undergoing locoregional therapy to the liver with 90Y microspheres.
- 26 November 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1129) , 20210294
Tumour-to-normal tissue (T/N) dosimetry ratios role in assessment of 90Y selective internal radiation therapy (SIRT)
Objective: The purpose of our work is to assess the role of tumour-to-normal tissue (T/N) dosimetry ratios for predicting response in patients undergoing locoregional therapy to the liver with 90Y microspheres. Methods: A total of 39 patients (7 female:32 male, mean age 68.3 ± 7.6 years), underwent positron emission tomography (PET)/CT imaging after treatment with 90Y microspheres. For attenuation correction and localization of the 90Y microspheres, the low-dose, non-diagnostic CT images from PET/CT were used. The acquisition took 15 min and the reconstruction matrix size was 200 × 200 × 75 mm and voxel size of 4.07 × 4.07 × 3.00 mm. For dosimetry calculations, the local deposition method with known activity of 90Y was used. For each patient, regions of interest for tumour(s) and whole liver were manually created; the normal tissue region of interest was created automatically. mRECIST criteria on MRI done at 1 month post-treatment and subsequently every 3 months after 90Y treatment, were used to assess response. Results: For 39 patients, the mean liver, tumour and normal tissue doses (mean ± SD) were, 55.17 ± 26.04 Gy, 911.87 ± 866.54 Gy and 47.79 ± 20.47 Gy, respectively. Among these patients, 31 (79%) showed complete response (CR) and 8 (21%) showed progression of disease (PD). For patients with CR, the mean T/N dose ratio obtained was 24.91 (range 3.09–80.12) and for patients with PD, the mean T/N dose ratio was significantly lower, at 6.69 (range 0.36–14.75). Conclusion: Our data show that patients with CR have a statistically higher T/N dose ratio than those with PD. Because, the number of PD cases was limited and partial volume effect was not considered, further investigation is warranted. Advances in knowledge: T/N dosimetry ratios can be used for assessing response in patients undergoing locoregional therapy to the liver with 90Y microspheres.
- 1 June 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 139, 109698
An estimate of 90Y dosimetry for bremsstrahlung SPECT/CT imaging in liver therapy with 90Y microspheres
- 1 June 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 139, 109698
An estimate of 90Y dosimetry for bremsstrahlung SPECT/CT imaging in liver therapy with 90Y microspheres
- Open Access
- 1 October 2020
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 19 (04) , 359-365
Comparison of posttherapy 90Y positron emission tomography/computed tomography dosimetry methods in liver therapy with 90Y microspheres
The aim of our study was to compare dosimetry methods for yttrium-90 (90Y) positron emission tomography/computed tomography (PET/CT). Twenty-five patients were taken to a PET/CT suite following therapy with 90Y microspheres. The low mA, nondiagnostic CT images were used for attenuation correction and localization of the 90Y microspheres. The acquisition time was 15 min, the reconstruction matrix size was 200 mm × 200 mm × 75 mm, and voxel size was 4.07 mm × 4.07 mm × 3.00 mm. Two software packages, MIM 6.8 and Planet Dose, were utilized to calculate 90Y dosimetry. Three methods were used for voxel-based dosimetry calculations: the local deposition method (LDM), LDM with scaling (LDMwS) for known injected activity, and a dose point kernel (DPK) method using the MIRD kernel. Only the DPK approach was applied to the Planet Dose software. LDM and LDMwS were only applied to the MIM software. The average total liver dosimetry values (mean ± standard deviation) were 60.93 ± 28.62 Gy, 53.59 ± 23.47 Gy, 55.33 ± 24.80 Gy, and 54.25 ± 23.70 Gy for LDMwS, LDM, DPK with MIM, and DPK with Planet Dose (DOSI), respectively. In most cases, the LDMwS method produced slightly higher dosimetry values than the other methods. The MIM and Planet Dose DPK dosimetry values (i.e., DPK vs. DOSI) were highly comparable. Bland–Altman analysis calculated a mean difference of 1.1 ± 2.2 Gy. The repeatability coefficient was 4.4 (7.9% of the mean). The MIM and Planet Dose DPK dosimetry values were practically interchangeable. 90Y dosimetry values obtained by all methods were similar, but LDMwS tended to produce slightly higher values.
- 1 October 2020
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 19 (04) , 359-365
Open AccessComparison of posttherapy 90Y positron emission tomography/computed tomography dosimetry methods in liver therapy with 90Y microspheres
The aim of our study was to compare dosimetry methods for yttrium-90 (90Y) positron emission tomography/computed tomography (PET/CT). Twenty-five patients were taken to a PET/CT suite following therapy with 90Y microspheres. The low mA, nondiagnostic CT images were used for attenuation correction and localization of the 90Y microspheres. The acquisition time was 15 min, the reconstruction matrix size was 200 mm × 200 mm × 75 mm, and voxel size was 4.07 mm × 4.07 mm × 3.00 mm. Two software packages, MIM 6.8 and Planet Dose, were utilized to calculate 90Y dosimetry. Three methods were used for voxel-based dosimetry calculations: the local deposition method (LDM), LDM with scaling (LDMwS) for known injected activity, and a dose point kernel (DPK) method using the MIRD kernel. Only the DPK approach was applied to the Planet Dose software. LDM and LDMwS were only applied to the MIM software. The average total liver dosimetry values (mean ± standard deviation) were 60.93 ± 28.62 Gy, 53.59 ± 23.47 Gy, 55.33 ± 24.80 Gy, and 54.25 ± 23.70 Gy for LDMwS, LDM, DPK with MIM, and DPK with Planet Dose (DOSI), respectively. In most cases, the LDMwS method produced slightly higher dosimetry values than the other methods. The MIM and Planet Dose DPK dosimetry values (i.e., DPK vs. DOSI) were highly comparable. Bland–Altman analysis calculated a mean difference of 1.1 ± 2.2 Gy. The repeatability coefficient was 4.4 (7.9% of the mean). The MIM and Planet Dose DPK dosimetry values were practically interchangeable. 90Y dosimetry values obtained by all methods were similar, but LDMwS tended to produce slightly higher values.
- Open Access
- 30 August 2018
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 5 (1) , 23-S680
Comparison of PET/CT and PET/MR imaging and dosimetry of yttrium-90 (90Y) in patients with unresectable hepatic tumors who have received intra-arterial radioembolization therapy with 90Y microspheres
The aim of our study was to compare 90Y dosimetry obtained from PET/MRI versus PET/CT post-therapy imaging among patients with primary or metastatic hepatic tumors. First, a water-filled Jaszczak phantom containing fillable sphere with 90Y-chloride was acquired on both the PET/CT and PET/MRI systems, in order to check the cross-calibration of the modalities. Following selective internal radiation therapy (SIRT) with 90Y microspheres, 32 patients were imaged on a PET/CT system, immediately followed by a PET/MRI study. Reconstructed images were transferred to a common platform and used to calculate 90Y dosimetry. A Passing-Bablok regression scatter diagram and the Bland and Altman method were used to analyze the difference between the dosimetry values. The phantom study showed that both modalities were calibrated with less than 1% error. The mean liver doses for the 32 subjects calculated from PET/CT and PET/MRI were 51.6 ± 24.7 Gy and 46.5 ± 22.7 Gy, respectively, with a mean difference of 5.1 ± 5.0 Gy. The repeatability coefficient was 9.0 (18.5% of the mean). The Spearman rank correlation coefficient was very high, ρ = 0.97. Although the maximum dose to the liver can be significantly different (up to 40%), mean liver doses from each modalities were relatively close, with a difference of 18.5% or less. The two main contributors to the difference in 90Y dosimetry calculations using PET/CT versus PET/MRI can be attributed to the differences in regions of interest (ROIs) and differences attributed to attenuation correction. Due to the superior soft-tissue contrast of MRI, liver contours are usually better seen than in CT images. However, PET/CT provides better quantification of PET images, due to better attenuation correction. In spite of these differences, our results demonstrate that the dosimetry values obtained from PET/MRI and PET/CT in post-therapy 90Y studies were similar.
- 30 August 2018
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 5 (1) , 23-S680
Open AccessComparison of PET/CT and PET/MR imaging and dosimetry of yttrium-90 (90Y) in patients with unresectable hepatic tumors who have received intra-arterial radioembolization therapy with 90Y microspheres
The aim of our study was to compare 90Y dosimetry obtained from PET/MRI versus PET/CT post-therapy imaging among patients with primary or metastatic hepatic tumors. First, a water-filled Jaszczak phantom containing fillable sphere with 90Y-chloride was acquired on both the PET/CT and PET/MRI systems, in order to check the cross-calibration of the modalities. Following selective internal radiation therapy (SIRT) with 90Y microspheres, 32 patients were imaged on a PET/CT system, immediately followed by a PET/MRI study. Reconstructed images were transferred to a common platform and used to calculate 90Y dosimetry. A Passing-Bablok regression scatter diagram and the Bland and Altman method were used to analyze the difference between the dosimetry values. The phantom study showed that both modalities were calibrated with less than 1% error. The mean liver doses for the 32 subjects calculated from PET/CT and PET/MRI were 51.6 ± 24.7 Gy and 46.5 ± 22.7 Gy, respectively, with a mean difference of 5.1 ± 5.0 Gy. The repeatability coefficient was 9.0 (18.5% of the mean). The Spearman rank correlation coefficient was very high, ρ = 0.97. Although the maximum dose to the liver can be significantly different (up to 40%), mean liver doses from each modalities were relatively close, with a difference of 18.5% or less. The two main contributors to the difference in 90Y dosimetry calculations using PET/CT versus PET/MRI can be attributed to the differences in regions of interest (ROIs) and differences attributed to attenuation correction. Due to the superior soft-tissue contrast of MRI, liver contours are usually better seen than in CT images. However, PET/CT provides better quantification of PET images, due to better attenuation correction. In spite of these differences, our results demonstrate that the dosimetry values obtained from PET/MRI and PET/CT in post-therapy 90Y studies were similar.
- Open Access
- 1 January 2018
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 17 (01) , 21-26
Comparison of standardized uptake value ratio calculations in amyloid positron emission tomography brain imaging
Amyloid positron emission tomography (PET) imaging with florbetapir 18F (18F-AV-45) allows in vivo assessment of cerebral amyloid load and can be used in the evaluation of progression of Alzheimer's disease (AD) and other dementias associated with b-amyloid. However, cortical amyloid deposition can occur in healthy cases, as well as in patients with AD and quantification of cortical amyloid burden can improve the 18F-AV-45 PET imaging evaluations. The quantification is mostly performed by cortical-to-cerebellum standardized uptake value ratio (SUVr). The aim of our study was to compare two methods for SUVr calculations in amyloid florbetapir 18F PET brain imaging. In amyloid florbetapir 18F PET brain imaging study, we imaged 42 cases with the mean age of 72.6 ± 9.9 (mean ± standard deviation). They were imaged on different PET/computed tomography systems with 369.0 ± 34.2 kBq of 18F florbetapir. Data were reconstructed using the vendor's reconstruction software. Corresponding magnetic resonance imaging (MRI) data were retrieved, and matched PET and MRI data were transferred to a common platform. Two methods were used for the calculation of the ratio of cortical-to-cerebellar signal (SUVr). One method was based on the MIM Software Inc., Version 6.4 software and only uses PET data. The second approach used the PMOD Neuro tool (version 3.5). This approach utilizes PET and corresponding MRI data (preferably T1-weighted) for better brain segmentation. For all the 42 cases, the average SUVr values for MIM and PMOD applications were 1.24 ± 0.26 and 1.22 ± 0.25, respectively, with a mean difference of 0.02 ± 0.15. The repeatability coefficient was 0.15 (12.3% of the mean). The Spearman's rank correlation coefficient was very high, r = 0.96. For amyloid-negative cases, the average SUVr values were lower than all group SUVr average values, 0.96 ± 0.07 and 1.00 ± 0.09, for MIM and PMOD applications, respectively. A mean difference was 0.04 ± 0.12, the repeatability coefficient was 0.12 (12.9% of the mean) and the Spearman's rank correlation coefficient was modest, r = 0.55. For amyloid-positive patients, the average SUVr values were higher than the same all grouP values, 1.34 ± 0.16 and 1.35 ± 0.20, respectively, with a mean difference of 0.01 ± 0.16. The repeatability coefficient was 0.16 (11.9% of the mean). The Spearman's rank correlation coefficient was high, r = 0.93. Our results indicated that the SUVr values derived using MIM and PMOD Neuro are effectively interchangeable and well correlated. However, PET template-based quantification (MIM approach) is clinically friendlier and easier to use. MRI template-based quantification (PMOD Neuro) better delineates different regions of the brain, can be used with any tracer, and therefore is more suitable for research.
- 1 January 2018
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 17 (01) , 21-26
Open AccessComparison of standardized uptake value ratio calculations in amyloid positron emission tomography brain imaging
Amyloid positron emission tomography (PET) imaging with florbetapir 18F (18F-AV-45) allows in vivo assessment of cerebral amyloid load and can be used in the evaluation of progression of Alzheimer's disease (AD) and other dementias associated with b-amyloid. However, cortical amyloid deposition can occur in healthy cases, as well as in patients with AD and quantification of cortical amyloid burden can improve the 18F-AV-45 PET imaging evaluations. The quantification is mostly performed by cortical-to-cerebellum standardized uptake value ratio (SUVr). The aim of our study was to compare two methods for SUVr calculations in amyloid florbetapir 18F PET brain imaging. In amyloid florbetapir 18F PET brain imaging study, we imaged 42 cases with the mean age of 72.6 ± 9.9 (mean ± standard deviation). They were imaged on different PET/computed tomography systems with 369.0 ± 34.2 kBq of 18F florbetapir. Data were reconstructed using the vendor's reconstruction software. Corresponding magnetic resonance imaging (MRI) data were retrieved, and matched PET and MRI data were transferred to a common platform. Two methods were used for the calculation of the ratio of cortical-to-cerebellar signal (SUVr). One method was based on the MIM Software Inc., Version 6.4 software and only uses PET data. The second approach used the PMOD Neuro tool (version 3.5). This approach utilizes PET and corresponding MRI data (preferably T1-weighted) for better brain segmentation. For all the 42 cases, the average SUVr values for MIM and PMOD applications were 1.24 ± 0.26 and 1.22 ± 0.25, respectively, with a mean difference of 0.02 ± 0.15. The repeatability coefficient was 0.15 (12.3% of the mean). The Spearman's rank correlation coefficient was very high, r = 0.96. For amyloid-negative cases, the average SUVr values were lower than all group SUVr average values, 0.96 ± 0.07 and 1.00 ± 0.09, for MIM and PMOD applications, respectively. A mean difference was 0.04 ± 0.12, the repeatability coefficient was 0.12 (12.9% of the mean) and the Spearman's rank correlation coefficient was modest, r = 0.55. For amyloid-positive patients, the average SUVr values were higher than the same all grouP values, 1.34 ± 0.16 and 1.35 ± 0.20, respectively, with a mean difference of 0.01 ± 0.16. The repeatability coefficient was 0.16 (11.9% of the mean). The Spearman's rank correlation coefficient was high, r = 0.93. Our results indicated that the SUVr values derived using MIM and PMOD Neuro are effectively interchangeable and well correlated. However, PET template-based quantification (MIM approach) is clinically friendlier and easier to use. MRI template-based quantification (PMOD Neuro) better delineates different regions of the brain, can be used with any tracer, and therefore is more suitable for research.
- Open Access
- 1 July 2015
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 14 (03) , 171-177
Improving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer′s Disease Studies
The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering.
- 1 July 2015
- Published by Georg Thieme Verlag KG in World Journal of Nuclear Medicine
- Vol. 14 (03) , 171-177
Open AccessImproving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer′s Disease Studies
The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering.
- 1 March 2015
- Vol. 59 (1) , 129-35
Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging.
The purpose of our study was to correctly fuse MRI and SPECT ¹¹¹In WBC and ⁹⁹m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy ¹¹¹In WBC/ ⁹⁹m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and ¹¹¹In WBC/ ⁹⁹m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq ¹¹¹In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7 ± 0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. ¹¹¹In WBC/⁹⁹m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. The CT in dual energy ¹¹¹In WBC/⁹⁹m Tc HDP SPECT/CT studies can be used to accurately fuse and compare ¹¹¹In WBC/⁹⁹m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.
- 1 March 2015
- Vol. 59 (1) , 129-35
Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging.
The purpose of our study was to correctly fuse MRI and SPECT ¹¹¹In WBC and ⁹⁹m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy ¹¹¹In WBC/ ⁹⁹m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and ¹¹¹In WBC/ ⁹⁹m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq ¹¹¹In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7 ± 0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. ¹¹¹In WBC/⁹⁹m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. The CT in dual energy ¹¹¹In WBC/⁹⁹m Tc HDP SPECT/CT studies can be used to accurately fuse and compare ¹¹¹In WBC/⁹⁹m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.
- Open Access
- 1 June 2010
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 9 (3) , 253-261
Quantitative Comparison of Yttrium-90 (90 Y)-Microspheres and Technetium-99m (99m Tc)-Macroaggregated Albumin SPECT Images for Planning 90 Y Therapy of Liver Cancer
Yttrium-90 (90 Y)-microspheres administered via the hepatic artery has been used for the treatment of unresectable primary or metastatic cancer in the liver. Prior to 90 Y therapy, however, the 90 Y administered activity and the percent shunting to lungs must be determined, most commonly by gamma camera imaging of technetium-99m (99m Tc)-macroaggregated albumin (MAA). The purpose of the current study was to identify and evaluate an objective measure of the correlation of 90 Y and MAA activity distributions and thus assess the reliability of MAA imaging for evaluation of 90 Y administered activity and tumor and liver radiation doses. The MAA study consisted of two acquisitions. After administration of 185 MBq of MAA, a partial-body or so-called breakthrough scan was performed in order to determine the percent shunting to lungs. Immediately after a breakthrough scan, a combined single-photon emission computed tomography (SPECT)/transmission computed tomography (CT) scanner was used to image MAA distribution in order to derived the prescribed 90 Y administered activity based on tumor and liver dosimetry. 90 Y SPECT/CT was performed 2–4 weeks later and activities used were in the range of 777–2,442 MBq. In order to compare 90 Y and MAA SPECT images, first the respective CT image sets were registered using a transform based on normalized mutual information. The transform thus derived was used to align the 90 Y and MAA SPECT image sets, and the Spearman's (rho) rank correlation as well as image distance (L2-norm) between the registered SPECT images were then calculated. The Spearman's rank correlation values ranged from 0.451 to 0.818 and the L2 distances from 0.626 to 2.889. Based on visual inspection, the registration of the 90 Y and MAA SPECT images appeared reasonably accurate. The regression coefficient (r) between visual scoring and the Spearman's rank correlation was 0.65 and between visual scoring and L2 distance 0.61. The Spearman's rank correlation thus appears to be more reliable than the image distance for assessing the correlation of the 90 Y and MAA images.
- 1 June 2010
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 9 (3) , 253-261
Open AccessQuantitative Comparison of Yttrium-90 (90 Y)-Microspheres and Technetium-99m (99m Tc)-Macroaggregated Albumin SPECT Images for Planning 90 Y Therapy of Liver Cancer
Yttrium-90 (90 Y)-microspheres administered via the hepatic artery has been used for the treatment of unresectable primary or metastatic cancer in the liver. Prior to 90 Y therapy, however, the 90 Y administered activity and the percent shunting to lungs must be determined, most commonly by gamma camera imaging of technetium-99m (99m Tc)-macroaggregated albumin (MAA). The purpose of the current study was to identify and evaluate an objective measure of the correlation of 90 Y and MAA activity distributions and thus assess the reliability of MAA imaging for evaluation of 90 Y administered activity and tumor and liver radiation doses. The MAA study consisted of two acquisitions. After administration of 185 MBq of MAA, a partial-body or so-called breakthrough scan was performed in order to determine the percent shunting to lungs. Immediately after a breakthrough scan, a combined single-photon emission computed tomography (SPECT)/transmission computed tomography (CT) scanner was used to image MAA distribution in order to derived the prescribed 90 Y administered activity based on tumor and liver dosimetry. 90 Y SPECT/CT was performed 2–4 weeks later and activities used were in the range of 777–2,442 MBq. In order to compare 90 Y and MAA SPECT images, first the respective CT image sets were registered using a transform based on normalized mutual information. The transform thus derived was used to align the 90 Y and MAA SPECT image sets, and the Spearman's (rho) rank correlation as well as image distance (L2-norm) between the registered SPECT images were then calculated. The Spearman's rank correlation values ranged from 0.451 to 0.818 and the L2 distances from 0.626 to 2.889. Based on visual inspection, the registration of the 90 Y and MAA SPECT images appeared reasonably accurate. The regression coefficient (r) between visual scoring and the Spearman's rank correlation was 0.65 and between visual scoring and L2 distance 0.61. The Spearman's rank correlation thus appears to be more reliable than the image distance for assessing the correlation of the 90 Y and MAA images.
- Open Access
- 29 January 2009
- Published by Springer Nature in BMC Medical Physics
- Vol. 9 (1) , 2
Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging
We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use.
- 29 January 2009
- Published by Springer Nature in BMC Medical Physics
- Vol. 9 (1) , 2
Open AccessRepeatability of regional myocardial blood flow calculation in 82Rb PET imaging
We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use.