THREE-DIMENSIONAL DOSIMETRY OF MAMMOGRAPHY USING A BLOCK CUBE BREAST PHANTOM AND RADIOCHROMIC FILM
- 20 October 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (3-4) , 226-233
Abstract
This study developed a phantom with a shape similar to that of the breast and use GAFCHROMIC films that can be placed inside the phantom to measure the detailed breast dose distribution in mammography. GAFCHROMIC EBT3 was placed on the block cube breast phantom and irradiated with a mammography device to measure the absorbed dose distribution inside the phantom in the horizontal and depth directions. The dose distribution in the horizontal plane was the highest in the centre on the chest wall side, and it decreased in a fan shape. Along the depth of the phantom, the doses absorbed across the entire cross-section were 16.15 mGy at the surface and 7.51, 3.25 and 1.68 mGy at depths of 10, 20 and 30 mm, respectively. Compared with the mean glandular dose, the proposed method can measure breast dose distributions in greater detail and is applicable to various breast shapes.Keywords
Funding Information
- Japan Society for the Promotion of Science (18 K07652)
This publication has 14 references indexed in Scilit:
- Dosimetry in x-ray-based breast imagingPhysics in Medicine & Biology, 2016
- Trends in mammography utilization for breast cancer screening in a Middle-Eastern country: Lebanon 2005–2013Cancer Epidemiology, 2015
- Optimizing Digital Mammographic Image Quality for Full-Field Digital Detectors: Artifacts Encountered during the QC ProcessRadioGraphics, 2015
- Breast-Cancer Screening — Viewpoint of the IARC Working GroupNew England Journal of Medicine, 2015
- Energy response of the GAFCHROMIC EBT3 in diagnosis range2015
- Three-dimensional dose distribution in contrast-enhanced digital mammography using Gafchromic XR-QA2 films: Feasibility studyRadiation Physics and Chemistry, 2014
- Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection modeAustralasian Physics & Engineering Sciences in Medicine, 2013
- Dose‐response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron‐produced monochromatic x‐ray beamsMedical Physics, 2012
- Energy response of the new EBT2 radiochromic film to x-ray radiationRadiation Measurements, 2010
- Average glandular dose conversion coefficients for segmented breast voxel modelsRadiation Protection Dosimetry, 2005