Tatsuhiro Gotanda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuhiro Gotanda has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Takuya Akagawa
Tokushima Red Cross Hospital
12 shared publications- Toshizo Katsuda
Shizuoka College of Medicalcare Science
9 shared publications Hidetoshi Yatake
Department of Breast Cancer Center, Kaizuka City Hospital , 3-10-20 Sakai, Kaizuka, Osaka 597-0015
5 shared publications- Rumi Gotanda
Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
5 shared publications - Shinnosuke Nishihara
Kawasaki University of Medical Welfare
5 shared publications Shinya Imai
Department of Radiological Science, Faculty of Health Science, Morinomiya University of Medical Sciences , 1-26-16 Nankokita, Suminoe-ku, Osaka 559-8611
5 shared publications
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 352-360
Response Characteristics of GAFCHROMIC LD-V1 When Used in Liquid Water
- 2 August 2026
- Published by Springer Nature
- p. 352-360
Response Characteristics of GAFCHROMIC LD-V1 When Used in Liquid Water
- 2 August 2026
- Published by Springer Nature
- p. 324-332
Establishment of a Method for Measuring Breast Surface Dose in Coronary CT Using Gafchromic Film
- 2 August 2026
- Published by Springer Nature
- p. 324-332
Establishment of a Method for Measuring Breast Surface Dose in Coronary CT Using Gafchromic Film
- 2 August 2026
- Published by Springer Nature
- p. 10-18
Evaluation of Lens Exposure Reduction Method Using Tilt Mechanism in 320-Row Head CT with Radiochromic Film
- 2 August 2026
- Published by Springer Nature
- p. 10-18
Evaluation of Lens Exposure Reduction Method Using Tilt Mechanism in 320-Row Head CT with Radiochromic Film
- 2 August 2026
- Published by Springer Nature
- p. 302-312
Response Characteristics of GAFCHROMIC LD-V1 with Different Lots and Scanners
- 2 August 2026
- Published by Springer Nature
- p. 302-312
Response Characteristics of GAFCHROMIC LD-V1 with Different Lots and Scanners
- 18 May 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (14) , 1096-1107
Eye lens dose distribution in neonatal head CT: an analysis of the scanning conditions and CTDIvol limitations
Despite neonatal radiosensitivity, accurate lens dose assessments in computed tomography (CT) are lacking. We assessed the neonatal head CT eye lens dose under various scanning conditions, including vertical table displacement and organ-based exposure modulation (OEM), using the GAFCHROMIC LD-V1 (LD-V1), which can measure two-dimensional dose distributions, and we evaluated the limitations of conventional dose indices. The lens dose decreased with increasing distance from the isocentre for the Canon 320. Whereas, for the Canon 80 and Siemens, the dose peaked at +25 mm and then decreased. For the OEM, the dose reduction effect decreased at 30°. The CT dose index volume remained consistent. Spatially resolved dosimetry using the LD-V1 reveals beam overlap and positioning-related dose anomalies that cannot be captured by point dosimeters or conventional indices. The LD-V1 can effectively evaluate superficial dose distributions and guide dose optimization in neonatal imaging.
- 18 May 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (14) , 1096-1107
Eye lens dose distribution in neonatal head CT: an analysis of the scanning conditions and CTDIvol limitations
Despite neonatal radiosensitivity, accurate lens dose assessments in computed tomography (CT) are lacking. We assessed the neonatal head CT eye lens dose under various scanning conditions, including vertical table displacement and organ-based exposure modulation (OEM), using the GAFCHROMIC LD-V1 (LD-V1), which can measure two-dimensional dose distributions, and we evaluated the limitations of conventional dose indices. The lens dose decreased with increasing distance from the isocentre for the Canon 320. Whereas, for the Canon 80 and Siemens, the dose peaked at +25 mm and then decreased. For the OEM, the dose reduction effect decreased at 30°. The CT dose index volume remained consistent. Spatially resolved dosimetry using the LD-V1 reveals beam overlap and positioning-related dose anomalies that cannot be captured by point dosimeters or conventional indices. The LD-V1 can effectively evaluate superficial dose distributions and guide dose optimization in neonatal imaging.
- Open Access
- 9 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70117
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net pixel value (NPV)‐absorbed dose calibration curves for the GAFCHROMIC LD‐V1 were generated using x‐rays with effective energies of 18, 30, 50, and 80 keV to reflect those used in different diagnostic radiographic modalities. The film response was analyzed using calibration curves at each energy level. The coefficients of determination for the calibration curves at 18, 30, 50, and 80 keV were 0.9992, 0.9997, 0.9999, and 0.9976, respectively. The pixel value change at 30 keV was the largest and most sensitive, while the smallest change in pixel value and lowest sensitivity were noted at 18 keV. Because the energy dependence of the GAFCHROMIC LD‐V1 is significant below 18 keV and above 80 keV, it is necessary to establish an appropriate NPV‐absorbed dose calibration curve for energies below 18 keV and consider the possibility of underestimating the dose at energies above 80 keV.
- 9 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70117
Open AccessEnergy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net pixel value (NPV)‐absorbed dose calibration curves for the GAFCHROMIC LD‐V1 were generated using x‐rays with effective energies of 18, 30, 50, and 80 keV to reflect those used in different diagnostic radiographic modalities. The film response was analyzed using calibration curves at each energy level. The coefficients of determination for the calibration curves at 18, 30, 50, and 80 keV were 0.9992, 0.9997, 0.9999, and 0.9976, respectively. The pixel value change at 30 keV was the largest and most sensitive, while the smallest change in pixel value and lowest sensitivity were noted at 18 keV. Because the energy dependence of the GAFCHROMIC LD‐V1 is significant below 18 keV and above 80 keV, it is necessary to establish an appropriate NPV‐absorbed dose calibration curve for energies below 18 keV and consider the possibility of underestimating the dose at energies above 80 keV.
- 22 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2391-2395
Comparison of sensitivity characteristics between GAFCHROMIC LD-V1 and GAFCHROMIC XR-QA2 in mammographic dosimetry
In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59–14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.
- 22 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2391-2395
Comparison of sensitivity characteristics between GAFCHROMIC LD-V1 and GAFCHROMIC XR-QA2 in mammographic dosimetry
In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59–14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.
- 24 May 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (8-9) , 1007-1011
Dosimetry using a radiochromic film and a mammography phantom
Mammography is one of the most effective diagnostic methods for the early detection of breast cancer; however, it poses the risk of radiation exposure. To date, mammography dosimetry has been performed according to the mean glandular dose; however, the actual exposure in the breast has not been assessed. Here, we have measured dose distributions and depth doses using both radiochromic films and mammographic phantoms, and a three-dimensional intra-mammary dose assessment was conducted. The absorbed dose distribution at the surface was markedly higher on the chest wall side but lower on the nipple side. The absorbed doses in the depth direction exponentially decreased. The glandular tissue near the surface may be irradiated with an absorbed dose of 7.0 mGy or higher. Since LD-V1 could be placed inside the phantom, the absorbed dose inside the breast could also be evaluated in three dimensions.
- 24 May 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (8-9) , 1007-1011
Dosimetry using a radiochromic film and a mammography phantom
Mammography is one of the most effective diagnostic methods for the early detection of breast cancer; however, it poses the risk of radiation exposure. To date, mammography dosimetry has been performed according to the mean glandular dose; however, the actual exposure in the breast has not been assessed. Here, we have measured dose distributions and depth doses using both radiochromic films and mammographic phantoms, and a three-dimensional intra-mammary dose assessment was conducted. The absorbed dose distribution at the surface was markedly higher on the chest wall side but lower on the nipple side. The absorbed doses in the depth direction exponentially decreased. The glandular tissue near the surface may be irradiated with an absorbed dose of 7.0 mGy or higher. Since LD-V1 could be placed inside the phantom, the absorbed dose inside the breast could also be evaluated in three dimensions.
- Open Access
- 1 December 2021
- Published by Elsevier in Physica Medica
- Vol. 92, S238
Non-uniformity error (noise) reduction of reflective type radiochromic films
- 1 December 2021
- Published by Elsevier in Physica Medica
- Vol. 92, S238
Open AccessNon-uniformity error (noise) reduction of reflective type radiochromic films
- 20 October 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (3-4) , 226-233
THREE-DIMENSIONAL DOSIMETRY OF MAMMOGRAPHY USING A BLOCK CUBE BREAST PHANTOM AND RADIOCHROMIC FILM
This study developed a phantom with a shape similar to that of the breast and use GAFCHROMIC films that can be placed inside the phantom to measure the detailed breast dose distribution in mammography. GAFCHROMIC EBT3 was placed on the block cube breast phantom and irradiated with a mammography device to measure the absorbed dose distribution inside the phantom in the horizontal and depth directions. The dose distribution in the horizontal plane was the highest in the centre on the chest wall side, and it decreased in a fan shape. Along the depth of the phantom, the doses absorbed across the entire cross-section were 16.15 mGy at the surface and 7.51, 3.25 and 1.68 mGy at depths of 10, 20 and 30 mm, respectively. Compared with the mean glandular dose, the proposed method can measure breast dose distributions in greater detail and is applicable to various breast shapes.
- 20 October 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (3-4) , 226-233
THREE-DIMENSIONAL DOSIMETRY OF MAMMOGRAPHY USING A BLOCK CUBE BREAST PHANTOM AND RADIOCHROMIC FILM
This study developed a phantom with a shape similar to that of the breast and use GAFCHROMIC films that can be placed inside the phantom to measure the detailed breast dose distribution in mammography. GAFCHROMIC EBT3 was placed on the block cube breast phantom and irradiated with a mammography device to measure the absorbed dose distribution inside the phantom in the horizontal and depth directions. The dose distribution in the horizontal plane was the highest in the centre on the chest wall side, and it decreased in a fan shape. Along the depth of the phantom, the doses absorbed across the entire cross-section were 16.15 mGy at the surface and 7.51, 3.25 and 1.68 mGy at depths of 10, 20 and 30 mm, respectively. Compared with the mean glandular dose, the proposed method can measure breast dose distributions in greater detail and is applicable to various breast shapes.