Mechanical Method for Rapid Determination of Step Count Sensor Settings
Open Access
- 27 May 2024
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 11 (6) , 547
Abstract
With the increased push for personalized medicine, researchers and clinicians have begun exploring the use of wearable sensors to track patient activity. These sensors typically prioritize device life over robust onboard analysis, which results in lower accuracies in step count, particularly at lower cadences. To optimize the accuracy of activity-monitoring devices, particularly at slower walking speeds, proven methods must be established to identify suitable settings in a controlled and repeatable manner prior to human validation trials. Currently, there are no methods for optimizing these low-power wearable sensor settings prior to human validation, which requires manual counting for in-laboratory participants and is limited by time and the cadences that can be tested. This article proposes a novel method for determining sensor step counting accuracy prior to human validation trials by using a mechanical camshaft actuator that produces continuous steps. Sensor error was identified across a representative subspace of possible sensor setting combinations at cadences ranging from 30 steps/min to 110 steps/min. These true errors were then used to train a multivariate polynomial regression to model errors across all possible setting combinations and cadences. The resulting model predicted errors with an R2 of 0.8 and root-mean-square error (RMSE) of 0.044 across all setting combinations. An optimization algorithm was then used to determine the combinations of settings that produced the lowest RMSE and median error for three ranges of cadence that represent disabled low-mobility ambulators, disabled high-mobility ambulators, and healthy ambulators (30–60, 20–90, and 30–110 steps/min, respectively). The model identified six setting combinations for each range of interest that achieved a ±10% error in cadence prior to human validation. The anticipated range of errors from the optimized settings at lower walking speeds are lower than the reported errors of wearable sensors (±30%), suggesting that pre-human-validation optimization of sensors may decrease errors at lower cadences. This method provides a novel and efficient approach to optimizing the accuracy of wearable activity monitors prior to human validation trials.Keywords
Funding Information
- Mayo Clinic Graduate School of Biomedical Sciences
- W. Hall Wendel Jr. Musculoskeletal Research Professorship
This publication has 21 references indexed in Scilit:
- Use of Wearable Devices in Individuals With or at Risk for Cardiovascular Disease in the US, 2019 to 2020JAMA Network Open, 2023
- Methods for the metrological characterization of wearable devices for the measurement of physiological signals: state of the art and future challengesMethodsX, 2023
- Can shank acceleration provide a clinically feasible surrogate for individual limb propulsion during walking?Journal of Biomechanics, 2020
- Gait Speed Reveals Clues to Lifelong HealthJAMA Network Open, 2019
- Association of Neurocognitive and Physical Function With Gait Speed in MidlifeJAMA Network Open, 2019
- Foot trajectories and loading rates in a transfemoral amputee for six different commercial prosthetic knees: An indication of adaptabilityMedical Engineering & Physics, 2019
- Relationship between Daily and In-laboratory Gait Speed among Healthy Community-dwelling Older AdultsScientific Reports, 2019
- Step Counting: A Review of Measurement Considerations and Health-Related ApplicationsSports Medicine, 2016
- Step detection using multi- versus single tri-axial accelerometer-based systemsPhysiological Measurement, 2015
- Validity of using tri-axial accelerometers to measure human movement – Part II: Step counts at a wide range of gait velocitiesMedical Engineering & Physics, 2014