DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION
Authors:
Open Access
- 1 September 2020
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Arquivos de Gastroenterologia
- Vol. 57 (3) , 316-322
Abstract
BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.Keywords
This publication has 28 references indexed in Scilit:
- STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy StudiesClinical Chemistry, 2015
- Advances in Fecal Occult Blood Tests: The FIT RevolutionDigestive Diseases and Sciences, 2014
- Most bowel cancer symptoms do not indicate colorectal cancer and polyps: a systematic reviewBMC Gastroenterology, 2011
- Diagnostic Yield Improves With Collection of 2 Samples in Fecal Immunochemical Test Screening Without Affecting AttendanceClinical Gastroenterology and Hepatology, 2011
- Comprehensive validation of the Boston Bowel Preparation ScaleGastrointestinal Endoscopy, 2010
- Influence of seasonal variations in ambient temperatures on performance of immunochemical faecal occult blood test for colorectal cancer screening: observational study from the Florence districtGut, 2010
- Comparison of a guaiac and an immunochemical faecal occult blood test for the detection of colonic lesions according to lesion type and locationBritish Journal of Cancer, 2009
- Use of Colonoscopy to Screen Asymptomatic Adults for Colorectal CancerNew England Journal of Medicine, 2000
- ROUTINE CHEMICAL TESTS OF THE STOOL FOR OCCULT BLOODThe American Journal of the Medical Sciences, 1965
- The importance of occult blood in the stoolDigestive Diseases and Sciences, 1948