PSPaulo Sakai

Paulo Sakai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paulo Sakai has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION

    by Rejane Mattar, Sergio Barbosa Marques, Maurício Kazuyoshi Minata, Joyce Matie Kinoshita da Silva-Etto, Paulo Sakai, Eduardo Guimarães Hourneaux DE Moura

    BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


  • Open Access

    Comparative study of strategies to prevent esophageal and periesophageal injury during atrial fibrillation ablation

    by Barbara Daniela de Oliveira, Helena Oyama, Carina Abigail Hardy, Sissy Lara de Melo, Cristiano Faria Pisani, Muhieddine Omar Chokr, Conrado Balbo, Francisco Carlos da Costa Darrieux, Denise Tessariol Hachul, Dalton Marques Chaves, et al.

    Objective: To compare the prevalence of esophageal and periesophageal thermal injury in patients undergoing radiofrequency (RF) atrial fibrillation (AF) ablation using 8 mm tip catheters during three different esophageal protection strategies.Methods: Forty‐five consecutive patients with paroxysmal or persistent AF underwent first ablation procedure, besides esophagogastroduodenoscopy (EGD) combined with radial endosonography (EUS) performed before and after the pulmonary vein (PV) isolation. Before the procedure, patients were randomly assigned to one of three esophageal lesion protection strategies: group I—without any protective or monitoring dispositive and limiting RF applications to 30 W for 20 seconds, in left atrium posterior wall (LAPW); group II—power and time of RF delivery, up to 50 W for 20 seconds at LAPW, limited by esophageal temperature monitoring; group III—applications of RF in LAPW with fixed power application of 50 W for 20 seconds during continuous esophageal cooling.Results: Baseline characteristics of patients were similar in all groups. The four PVs were isolated in 14 (93.3%), 13 (86.7%), and 15 (100%) patients, respectively in groups I, II, and III. The mean RF power was significantly higher (P < .001) in the posterior side of PVs in group III. Post‐AF ablation EGD and EUS revealed two esophageal wall ulcerations and two periesophageal mediastinal edemas only in the esophageal cooling group (P = .008).Conclusion: Esophageal cooling balloon strategy resulted in a higher RF power energy delivery when ablating at the LA posterior wall, using 8 mm nonirrigated tip catheters under temperature mode control. Despite that, patients presented a relatively low incidence of esophageal and periesophaeal injuries.


  • Open Access

    Volumetric laser endomicroscopy and optical coherence tomography in Barrett’s esophagus: a systematic review and meta-analysis

    by Maria Auxiliadora Chóez Rodriguez, Diogo Turiani Hourneaux de Moura, Igor Braga Ribeiro, Wanderley Marques Bernardo, Flavio Hiroshi Ananias Morita, Sergio Barbosa Marques, Paulo Sakai, Eduardo Guimarães Hourneaux de Moura

    Background and study aims Endoscopic imaging of Barrett’s esophagus (BE) with advanced technologies, such as optical coherence tomography (OCT) and volumetric laser endomicroscopy (VLE), allows targeted biopsies and may reduce the number of random biopsies to detect esophageal neoplasia in the early stages during endoscopic BE surveillance. The aim of this study was to evaluate the accuracy of OCT and VLE in diagnosis of intestinal metaplasia, dysplasia, and high-grade dysplasia (HGD), and intramucosal carcinoma (IMC) in BE. Patients and methods In this systematic review and meta-analysis, the primary outcome measure was diagnostic accuracy of OCT and VLE, in comparison with the gold standard. In the meta-analysis, we calculated sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for both methods. We performed analyses by patient and by lesion. Results We evaluated 14 studies involving a collective total of 721 patients and 1565 lesions. In the analysis by lesion, VLE showed a pooled sensitivity, specificity, LR+, LR−, DOR, and SROC AUC of 85 %, 73 %, 3.2, 0.21, 15.0, and 0.87, respectively, for detection of HGD/IMC. In the analysis by lesion for detection of HGD/EAC, OCT showed a pooled sensitivity, specificity, LR+, LR−, DOR, and summary receiver operating characteristic area under the curve of 89 %, 91 %, 9.6, 0.12, 81.0, and 0.95, respectively. The accuracy of OCT in identifying intestinal metaplasia showed a pooled sensitivity, specificity, LR+, LR−, and DOR of 92 %, 81 %, 5.06, 0.091, and 55.58, respectively. Conclusion OCT- and VLE-guided targeted biopsies could improve detection of dysplasia and neoplasia. Further studies could determine whether the use of such biopsies might replace the current protocol.


  • Open Access

    Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial

    by Carlos Kiyoshi Furuya, Paulo Sakai, Fabio Ramalho Tavares Marinho, Jose Pinhata Otoch, Spencer Cheng, Lívia Lemes Prudencio, Eduardo Guimarães Hourneaux de Moura, Everson Luiz de Almeida Artifon

    Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial


  • Open Access

    SEDATION IN COLONOSCOPY BY USING THREE DIFFERENT PROPOFOL INFUSION METHODS AND ANALYSIS OF PLASMA CONCENTRATION LEVELS: A PROSPECTIVE COMPARATIVE STUDY

    by Paulo Henrique Boaventura De Carvalho, José Pinhata Otoch, Mohamad Ali Khan, Paulo Sakai, Hugo Gonçalo Guedes, Everson Luiz De Almeida Artifon

    Background: The propofolemia becomes directly linked to the clinical effects of this anesthetic and is the focus for studies comparing propofol clinical use, in different administration methods routinely used in endoscopy units where sedation is widely administered to patients. Aim: To evaluate the effects of three different regimens of intravenous propofol infusion in colonoscopies. Methods: A total of 50 patients that underwent colonoscopies were consecutively assigned to three groups: 1) intermittent bolus infusion; 2) continuous manually controlled infusion; 3) continuous automatic infusion. Patients were monitored with Bispectral IndexTM (BIS) and propofol serum levels were collected at three different timepoints. The development of an original dilution of propofol and an inventive capnography catheter were necessary. Results: Regarding clinical outcomes, statistical differences in agitation (higher in group 1, p=0.001) and initial blood pressure (p=0.008) were found. As for propofol serum levels, findings were similar in consumption per minute (p=0.748) and over time (p=0.830). In terms of cost analysis, group 1 cost was R$7.00 (approximately US$2,25); group2, R$17.50 (approximately US$5,64); and group 3, R$112.70 (approximately US$36,35, p


  • Endoscopic ultrasound-guided choledochoduodenostomy and duodenal stenting in patients with unresectable periampullary cancer: one-step procedure by using linear echoendoscope

    by Everson L. A. Artifon, Mariana S. V. Frazão, Stephanie Wodak, Fred Olavo A. A. Carneiro, Jonas Takada, Carolina Rabello, Dayse Aparício, Eduardo Guimarães Hourneaux de Moura, Paulo Sakai, José Pinhata Otoch

    Objective. Describe a case series of endoscopic ultrasound (EUS)-guided choledochoduodenostomy (EUS-CD) associated with duodenal self-expandable metal stents (SEMS) placement using solely the linear echoendoscope in seven patients with obstructive jaundice and duodenal obstruction due to unresectable periampullary cancer. Material and methods. EUS-CD in the first portion of the duodenum, associated with duodenal SEMS placement was performed in seven patients with unresectable periampullary cancer with obstructive jaundice and invasive duodenal obstruction. Laboratory tests and clinical follow-up were performed until patient's death. The procedure was performed by an experienced endoscopist under conscious sedation. The puncture position was chosen based on EUS evaluation, at the common bile duct (CBD) above the tumor, through the distal part of the duodenal bulb. After that, the needle was withdrawn and a wire-guided needle knife was used to enlarge the site puncture in the duodenal wall. Then, a partially covered SEMS was passed over the guide, through the choledochoduodenal fistula. Duodenal SEMS placement was performed during the same endoscopic procedure. Results. The procedure was performed in seven patients, ranging between 34 and 86 years. Technical success of EUS-CD, by the stent placement, occurred in 100% of the cases. There were no early complications. Duodenal SEMS placement was effective in 100% of the cases that remained alive after a follow-up of 7 and 30 days. Conclusion. The results suggest therapeutic EUS one-step procedure drainage as an alternative for these patients, with good clinical success, feasible technique and safety.


  • PEG rescue with gastropexy after early tube withdrawal: an application of natural orifice transluminal endoscopic surgery (with video)

    by Bruno da Costa Martins, Jonas Takada, Fábio Shiguehissa Kawaguti, João Paulo Aguiar Ribeiro, Fábio Yuji Hondo, Marcelo Simas de Lima, Carla Zanellatto Neves, Caio Sérgio R. Nahas, Carlos Frederico Sparapan Marques, Paulo Sakai, et al.


  • An evaluation of gastric scintigraphy pre- and postpyloroduodenal peptic stenosis dilation

    by E. L. A. Artifon, P. Sakai, F. Y. Hondo, F. P. Lopasso, S. Ishioka, J. J. Gama-Rodrigues

    The usual treatment of pyloroduodenal peptic stenosis has been mainly surgical, through pyloroplasty or gastric resection, with or without vagotomy. Since the first description of treatment for this peptic complication by endoscopic balloon dilation perfomed by Benjamin in 1982 [2], this procedure has become a therapeutic option in association with the medical treatment of peptic disease. The aim of this study is to evaluate the results involving clinical, endoscopic, and gastric emptying scintigraphy parameters. Between August 1998 and February 2000, 20 patients with pyloroduodenal stenosis refractory to conservative treatment were treated at the Gastrointestinal Endoscopy Unit of the University of São Paulo Medical School. All patients who presented clinical manifestations of pyloroduodenal stenosis underwent upper gastrointestinal endoscopy to confirm peptic stenosis. Biopsy of the narrowing for the confirmation of a benign disease and gastric biopsy for Helicobacter pylori detection were performed. The treatment consisted of dilation of the stenosis with type TTS (Through The Scope) hydrostatic balloon under endoscopic control, treatment of Helicobacter pylori infection, and gastric acid suppression with oral administration of proton pump inhibitor. All patients, except one who was excluded from this study, were submitted to a clinical endoscopic assessment and gastric emptying evaluation by ingestion of 99mTc before and after the treatment. Endoscopic evaluation considered the diameter of the stenotic area before and after treatment. A scintigraphic study compared the time of gastric emptying before and after balloon dilation. Nineteen patients completed treatment by hydrostatic balloon dilation. Clinical symptoms such as bloating (p < 0.0001), epigastric pain (p = 0.0159), gastric stasis (p < 0.0001), and weight gain (p = 0.036) showed significant improvement. The diameter of the stenotic area increased significantly (p < 0.01) after the dilation treatment as well as a better gastric emptying of 99mTc (p < 0.0001). The dilation of the peptic pyloroduodenal stenosis using a hydrostatic balloon is a safe and effective procedure. The evaluation with gastric scintigraphy by ingestion of 99mTc is an effective method of assessment for the improvement of gastric function, because its results corresponded to the clinical improvement after endoscopic treatment.