Wearable Fluidic Fabric with Excellent Heat Transfer Performance for Sports Recovery
Open Access
- 7 January 2025
- journal article
- research article
- Published by Wiley in Advanced Science
- Vol. 12 (8) , e2411691
Abstract
Rapid temperature contrast hydrotherapy by water immersion has been utilized by athletes for effective sports recovery. However, its application at some training or competition venues is limited by high water consumption, bucky size, personal hygiene, and inconvenience. Here, a novel portable system equipped with highly effective, lightweight, and hygienic wearable fluidic fabric device is reported, that replaces direct water immersion. The measured heat transfer coefficient between the skin and the fabric is 98.5 W m−2 K−1, which is 92% of that in direct water immersion at 10 °C and significantly higher than that by previously reported cooling garments. The core layer, a flexible heat transfer panel (FHTP), can switch between cold and hot modes (5–40 °C) over an area of 0.3 m2. The contact condition between skin and the deformable FHTP has been considered in a new verified heat transfer model. Optimization of the parameters has resulted in excellent heat transfer performance. This fluidic fabric also holds potential in diverse applications, such as enhancing thermal safety and comfort in extreme environments (e.g., personal thermal management systems and fire‐protection suits), supporting cryotherapy and thermotherapy in rehabilitation and healthcare, and simulation of total tactile sensations in virtual reality.Keywords
Funding Information
- Hong Kong Polytechnic University (847A)
This publication has 33 references indexed in Scilit:
- A multimodal cooling garment for personal thermal comfort managementApplied Energy, 2023
- Performance Optimization of a Thermoelectric‐Water Hybrid Cooling GarmentAdvanced Materials Technologies, 2023
- Realizing a 10 °C Cooling Effect in a Flexible Thermoelectric Cooler Using a Vortex GeneratorAdvanced Materials, 2022
- Multi-objective optimization of thermal-hydraulic performance in a microchannel heat sink with offset ribs using the fuzzy grey approachApplied Thermal Engineering, 2022
- Man-portable cooling garment with cold liquid circulation based on thermoelectric refrigerationApplied Thermal Engineering, 2022
- Advanced Thermoelectric Materials for Flexible Cooling ApplicationAdvanced Functional Materials, 2021
- Orthogonal experimental design of liquid-cooling structure on the cooling effect of a liquid-cooled battery thermal management systemApplied Thermal Engineering, 2018
- Assessment of an active liquid cooling garment intended for use in a hot environmentApplied Ergonomics, 2017
- The effect of body postures on the distribution of air gap thickness and contact areaInternational Journal of Biometeorology, 2016
- Comparison between cold water immersion therapy (CWIT) and light emitting diode therapy (LEDT) in short-term skeletal muscle recovery after high-intensity exercise in athletes—preliminary resultsLasers in Medical Science, 2010