This study presents a wearable knee joint monitoring system for estimating knee angles during physiotherapy using a single inertial sensor. Conventional multi-sensor configurations often face limitations in scalability due to increased setup complexity, user discomfort, and higher system cost, motivating the development of a simplified single-sensor approach. Four physiotherapy exercises were evaluated: seated flexion–extension (F–E), supine knee extension (KE), quadriceps mini-squats (QMS), and level walking. Data were collected from ten healthy participants performing these activities in a home environment using inertial sensors attached to the lower limb. Accelerometer and gyroscope signals capturing the dynamics of knee motion were used to estimate joint angles through movement-specific stacked Long Short-Term Memory (LSTM) models, with input from a single sensor positioned on the shank. Unlike existing studies that primarily focus on gait, this work validates a data-driven approach across multiple physiotherapy movements and postures. Both personalized models and generalized models using leave-one-subject-out cross-validation were developed and evaluated. The personalized models achieved mean absolute errors (MAE) of 1.30◦ ± 0.57◦ for seated F–E, 2.43◦ ± 0.40◦ for supine KE, 2.79◦ ± 0.82◦ for QMS, and 2.71◦ ± 0.69◦ for walking, all within the minimal clinically important difference (MCID) of 6◦. Generalized models showed higher errors but maintained acceptable performance for certain activities. Overall, the proposed approach demonstrates clinically viable knee-angle estimation using a low-complexity wearable system, supporting its potential for home-based rehabilitation monitoring and telehealth applications.