Maryam Shojaei Baghini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maryam Shojaei Baghini has a total of 247 co-authors. Here are the top co-authors by number of shared publications:
- Valipe Ramgopal Rao
Department of Electrical Engineering, IIT Bombay, Mumbai, India
29 shared publications - Laxmeesha Somappa
IIT Bombay
18 shared publications - Shahid Malik
Indian Institute of Technology Delhi
12 shared publications - Meraj Ahmad
James Watt School of Engineering, University of Glasgow, Glasgow, U.K.
8 shared publications Harald Gossner
Intel Corp. Mobile and Communications Group, Munich 80336, Germany
7 shared publicationsMayank Shrivastava
Advance Nanoelectronic Device and Circuit Research Laboratory, Department of ESE, IISc-Bangalore, India
7 shared publications
Latest Publications
- Open Access
- 19 August 2026
- Published by Elsevier in SSRN Electronic Journal
Deep Learning–based Knee-angle Estimation using a Single Wearable Inertial Sensor for Physiotherapy Monitoring
This study presents a wearable knee joint monitoring system for estimating knee angles during physiotherapy using a single inertial sensor. Conventional multi-sensor configurations often face limitations in scalability due to increased setup complexity, user discomfort, and higher system cost, motivating the development of a simplified single-sensor approach. Four physiotherapy exercises were evaluated: seated flexion–extension (F–E), supine knee extension (KE), quadriceps mini-squats (QMS), and level walking. Data were collected from ten healthy participants performing these activities in a home environment using inertial sensors attached to the lower limb. Accelerometer and gyroscope signals capturing the dynamics of knee motion were used to estimate joint angles through movement-specific stacked Long Short-Term Memory (LSTM) models, with input from a single sensor positioned on the shank. Unlike existing studies that primarily focus on gait, this work validates a data-driven approach across multiple physiotherapy movements and postures. Both personalized models and generalized models using leave-one-subject-out cross-validation were developed and evaluated. The personalized models achieved mean absolute errors (MAE) of 1.30◦ ± 0.57◦ for seated F–E, 2.43◦ ± 0.40◦ for supine KE, 2.79◦ ± 0.82◦ for QMS, and 2.71◦ ± 0.69◦ for walking, all within the minimal clinically important difference (MCID) of 6◦. Generalized models showed higher errors but maintained acceptable performance for certain activities. Overall, the proposed approach demonstrates clinically viable knee-angle estimation using a low-complexity wearable system, supporting its potential for home-based rehabilitation monitoring and telehealth applications.
- 19 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDeep Learning–based Knee-angle Estimation using a Single Wearable Inertial Sensor for Physiotherapy Monitoring
This study presents a wearable knee joint monitoring system for estimating knee angles during physiotherapy using a single inertial sensor. Conventional multi-sensor configurations often face limitations in scalability due to increased setup complexity, user discomfort, and higher system cost, motivating the development of a simplified single-sensor approach. Four physiotherapy exercises were evaluated: seated flexion–extension (F–E), supine knee extension (KE), quadriceps mini-squats (QMS), and level walking. Data were collected from ten healthy participants performing these activities in a home environment using inertial sensors attached to the lower limb. Accelerometer and gyroscope signals capturing the dynamics of knee motion were used to estimate joint angles through movement-specific stacked Long Short-Term Memory (LSTM) models, with input from a single sensor positioned on the shank. Unlike existing studies that primarily focus on gait, this work validates a data-driven approach across multiple physiotherapy movements and postures. Both personalized models and generalized models using leave-one-subject-out cross-validation were developed and evaluated. The personalized models achieved mean absolute errors (MAE) of 1.30◦ ± 0.57◦ for seated F–E, 2.43◦ ± 0.40◦ for supine KE, 2.79◦ ± 0.82◦ for QMS, and 2.71◦ ± 0.69◦ for walking, all within the minimal clinically important difference (MCID) of 6◦. Generalized models showed higher errors but maintained acceptable performance for certain activities. Overall, the proposed approach demonstrates clinically viable knee-angle estimation using a low-complexity wearable system, supporting its potential for home-based rehabilitation monitoring and telehealth applications.
- 28 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Robust EIT reconstruction algorithm using hybrid Gauss–Newton and level-set method with adaptive mesh refinement
- 28 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Robust EIT reconstruction algorithm using hybrid Gauss–Newton and level-set method with adaptive mesh refinement
- Open Access
- 9 October 2025
- Published by Association for Computing Machinery (ACM) in ACM Journal on Emerging Technologies in Computing Systems
- Vol. 21 (4) , 1-18
Analog and Temporary On-chip Memory for ANN Training and Inference
On-chip training at the edge becomes a primary requisite for real-time and security-sensitive artificial neural network (ANN) applications. In-memory computation (IMC) techniques have been proposed to facilitate data-intensive computational operations in ANNs. IMC-based multiply-accumulate (MAC) accelerates ANN training but suffers from significant communication overhead between the MAC engine and the off-chip storage for the intermediate data. This article proposes an analog temporary on-chip memory (ATOM) to store this intermediate data during ANN training. The ANN training architecture with the proposed ATOM has two significant advantages. First, the energy required to store intermediate data is scaled down by \(\sim\) 40 \(\times\) due to the on-chip and analog nature of the memory. Second, the proposed architecture avoids power and area-consuming analog-to-digital converters (ADCs) between neural network stages. The ATOM cell measurements are carried out from 20 fabricated chips, and the impact of ATOM characteristics on ANN system performance accuracy is analyzed. This article shows significant latency improvement of \(\sim\) 9 \(\times\) and area savings of \(\sim\) 5 \(\times\) for intermediate data storage compared to the on-chip SRAM during ANN training’s forward and backward pass operations. An improvement in the area and latency will be beneficial to instrument the area- and energy-efficient hardware system for on-chip ANN applications.- 9 October 2025
- Published by Association for Computing Machinery (ACM) in ACM Journal on Emerging Technologies in Computing Systems
- Vol. 21 (4) , 1-18
Open AccessAnalog and Temporary On-chip Memory for ANN Training and Inference
On-chip training at the edge becomes a primary requisite for real-time and security-sensitive artificial neural network (ANN) applications. In-memory computation (IMC) techniques have been proposed to facilitate data-intensive computational operations in ANNs. IMC-based multiply-accumulate (MAC) accelerates ANN training but suffers from significant communication overhead between the MAC engine and the off-chip storage for the intermediate data. This article proposes an analog temporary on-chip memory (ATOM) to store this intermediate data during ANN training. The ANN training architecture with the proposed ATOM has two significant advantages. First, the energy required to store intermediate data is scaled down by \(\sim\) 40 \(\times\) due to the on-chip and analog nature of the memory. Second, the proposed architecture avoids power and area-consuming analog-to-digital converters (ADCs) between neural network stages. The ATOM cell measurements are carried out from 20 fabricated chips, and the impact of ATOM characteristics on ANN system performance accuracy is analyzed. This article shows significant latency improvement of \(\sim\) 9 \(\times\) and area savings of \(\sim\) 5 \(\times\) for intermediate data storage compared to the on-chip SRAM during ANN training’s forward and backward pass operations. An improvement in the area and latency will be beneficial to instrument the area- and energy-efficient hardware system for on-chip ANN applications. - 27 September 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 396
AquaSys: An autonomous, wireless real-time water quality monitoring system for pH and temperature measurement
- 27 September 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 396
AquaSys: An autonomous, wireless real-time water quality monitoring system for pH and temperature measurement
- 25 April 2025
- Published by Elsevier in Pervasive and Mobile Computing
- Vol. 110
EdgePlantNet: Lightweight edge-aware cyber–physical system for plant disease detection using enhanced attention CNNs
- 25 April 2025
- Published by Elsevier in Pervasive and Mobile Computing
- Vol. 110
EdgePlantNet: Lightweight edge-aware cyber–physical system for plant disease detection using enhanced attention CNNs
- Open Access
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 112 (10) , 1610-1631
High-k Metal–Insulator–Metal Capacitors for RF and Mixed-Signal VLSI Circuits: Challenges and Opportunities
Metal–insulator–metal (MIM) capacitors are inevitable and critical passive components in analog, mixed-signal, and memory applications. These capacitors occupy nearly 40% of circuit area among other passive and active components of the integrated circuit (IC). Considering this fact, the International Roadmap for Devices and Systems (IRDS) recognized and recommended the miniaturization of MIM capacitors with high permittivity dielectric materials. For future analog and radio frequency (RF) applications, the IRDS has predicted that MIM capacitors should hold a high capacitance density of $>$ $\text{10}$ $\text{fF}/\mu \text{m}^{\text{2}}$ , a low voltage linearity of $<$ $\text{100}$ $\text{ppm}/\text{V}^{\text{2}}$ , and a low leakage current density of $<$ $\text{10}$ $\text{nA}/\text{cm}^{\text{2}}$ . In this regard, many research works have been carried out over the last few decades with various high-k dielectrics to achieve “low voltage linearity.” However, many of them are facing problems with structural defects, interface traps, and poor polarization process due to limitations of fabrication processes. This article attempts to review the challenges and opportunities involved in the reduction of voltage linearity and leakage of MIM capacitors. Also, this article presents the physical limits and challenges involved in MIM capacitor integration with back end of line (BEOL) process of recent complementary metal–oxide–semiconductor (CMOS) technologies. Using physical modeling, the design formula for low voltage linearity coefficient was derived, which helps IC developers in the design and implementation of highly linear RF-analog and mixed-signal (AMS) systems.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 112 (10) , 1610-1631
Open AccessHigh-k Metal–Insulator–Metal Capacitors for RF and Mixed-Signal VLSI Circuits: Challenges and Opportunities
Metal–insulator–metal (MIM) capacitors are inevitable and critical passive components in analog, mixed-signal, and memory applications. These capacitors occupy nearly 40% of circuit area among other passive and active components of the integrated circuit (IC). Considering this fact, the International Roadmap for Devices and Systems (IRDS) recognized and recommended the miniaturization of MIM capacitors with high permittivity dielectric materials. For future analog and radio frequency (RF) applications, the IRDS has predicted that MIM capacitors should hold a high capacitance density of $>$ $\text{10}$ $\text{fF}/\mu \text{m}^{\text{2}}$ , a low voltage linearity of $<$ $\text{100}$ $\text{ppm}/\text{V}^{\text{2}}$ , and a low leakage current density of $<$ $\text{10}$ $\text{nA}/\text{cm}^{\text{2}}$ . In this regard, many research works have been carried out over the last few decades with various high-k dielectrics to achieve “low voltage linearity.” However, many of them are facing problems with structural defects, interface traps, and poor polarization process due to limitations of fabrication processes. This article attempts to review the challenges and opportunities involved in the reduction of voltage linearity and leakage of MIM capacitors. Also, this article presents the physical limits and challenges involved in MIM capacitor integration with back end of line (BEOL) process of recent complementary metal–oxide–semiconductor (CMOS) technologies. Using physical modeling, the design formula for low voltage linearity coefficient was derived, which helps IC developers in the design and implementation of highly linear RF-analog and mixed-signal (AMS) systems.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (12) , 1-4
High-Throughput Antimicrobial Susceptibility Assessment Using Non- Faradaic Electrochemical Impedance Spectroscopy
In this article, we present a label free antimicrobial susceptibility test (AST) using non-faradaic electrochemical impedance spectroscopy (nf-EIS) as a viable method to rapidly quantify antibiotic resistance. Different antibiotic resistant strains of Shewanella oneidensis were used as a model bacteria to measure minimum inhibitory concentration (MIC) of antibiotic namely kanamaycin needed to kill sufficient microbes. The device consists of gold interdigitated electrodes (IDE) on Polyethylene terephthalate (PET) substrate that can process 50 μL volume in less than 10 minutes. After incubating the bacteria with kanamycin for 10 minutes, roughly 106 cells are analyzed using impedance spectroscopy. The observed Bode magnitude and phase plots for different strains of S. oneidensis reflect the antibiotic action on the strains and its minimum concentration requirement for its effect is determined and the data is further used to develop an equivalent electrical model to quantify the susceptibility.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (12) , 1-4
High-Throughput Antimicrobial Susceptibility Assessment Using Non- Faradaic Electrochemical Impedance Spectroscopy
In this article, we present a label free antimicrobial susceptibility test (AST) using non-faradaic electrochemical impedance spectroscopy (nf-EIS) as a viable method to rapidly quantify antibiotic resistance. Different antibiotic resistant strains of Shewanella oneidensis were used as a model bacteria to measure minimum inhibitory concentration (MIC) of antibiotic namely kanamaycin needed to kill sufficient microbes. The device consists of gold interdigitated electrodes (IDE) on Polyethylene terephthalate (PET) substrate that can process 50 μL volume in less than 10 minutes. After incubating the bacteria with kanamycin for 10 minutes, roughly 106 cells are analyzed using impedance spectroscopy. The observed Bode magnitude and phase plots for different strains of S. oneidensis reflect the antibiotic action on the strains and its minimum concentration requirement for its effect is determined and the data is further used to develop an equivalent electrical model to quantify the susceptibility.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 7, 215-218
A 42.3 μm² Band to Band Tunneling-Based Oscillator Enabled Temperature to Digital Converter With Resolution FoM of 0.16 pJK² for Embedded Temperature Sensing
In advanced high-speed integrated systems, the widely distributed and proliferation of temperature sensors to detect hotspots improve the robustness and reliability of the system by preventing overheating. Low area and low energy consumption are essential for integrated temperature sensors in such applications. The band-to-band tunneling (BTBT) current in PDSOI technology increases linearly with temperature. We demonstrate a BTBT-based temperature-dependent oscillator. The fabricated oscillator has a low footprint (42.3 μm2, 10× less than state-of-the-art temperature sensing cores) and enables low energy consuming temperature to digital converter (0.32 nJ energy/conversion) in GF45RFSOI technology. The proposed oscillator facilitates an area and energy-efficient temperature sensor (20 °C to 90 °C) with a simple counter-based digital readout with a best-in-class resolution FoM of 0.16 pJK2.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 7, 215-218
A 42.3 μm² Band to Band Tunneling-Based Oscillator Enabled Temperature to Digital Converter With Resolution FoM of 0.16 pJK² for Embedded Temperature Sensing
In advanced high-speed integrated systems, the widely distributed and proliferation of temperature sensors to detect hotspots improve the robustness and reliability of the system by preventing overheating. Low area and low energy consumption are essential for integrated temperature sensors in such applications. The band-to-band tunneling (BTBT) current in PDSOI technology increases linearly with temperature. We demonstrate a BTBT-based temperature-dependent oscillator. The fabricated oscillator has a low footprint (42.3 μm2, 10× less than state-of-the-art temperature sensing cores) and enables low energy consuming temperature to digital converter (0.32 nJ energy/conversion) in GF45RFSOI technology. The proposed oscillator facilitates an area and energy-efficient temperature sensor (20 °C to 90 °C) with a simple counter-based digital readout with a best-in-class resolution FoM of 0.16 pJK2.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41081-41089
Current-Excitation-Based ΔR-to-Frequency Converter for Resistive Sensors
This paper presents a relaxation oscillator-based high-resolution resistance measurement system. The proposed signal conditioning circuit utilizes a half-bridge topology with a bidirectional current excitation. The circuit modulates the incremental change in the sensor resistance in the form of a change in the frequency of the relaxation oscillator. The baseline resistance of the sensor is automatically compensated using a digital potentiometer at the beginning of the measurement cycle. The proposed circuit is analyzed in detail by considering the non-idealities of the circuit components. The design consideration is provided for different components. A prototype PCB of the proposed circuit is developed. The results show that the proposed circuit can provide a signal-to-noise ratio of 80 dB for a wide-range incremental change in the sensor resistance up to 500 kΩ with an error of less than ± 1%. The developed board is tested with humidity sensors. The result confirms the efficacy of the proposed circuit for a wide measurement range.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41081-41089
Current-Excitation-Based ΔR-to-Frequency Converter for Resistive Sensors
This paper presents a relaxation oscillator-based high-resolution resistance measurement system. The proposed signal conditioning circuit utilizes a half-bridge topology with a bidirectional current excitation. The circuit modulates the incremental change in the sensor resistance in the form of a change in the frequency of the relaxation oscillator. The baseline resistance of the sensor is automatically compensated using a digital potentiometer at the beginning of the measurement cycle. The proposed circuit is analyzed in detail by considering the non-idealities of the circuit components. The design consideration is provided for different components. A prototype PCB of the proposed circuit is developed. The results show that the proposed circuit can provide a signal-to-noise ratio of 80 dB for a wide-range incremental change in the sensor resistance up to 500 kΩ with an error of less than ± 1%. The developed board is tested with humidity sensors. The result confirms the efficacy of the proposed circuit for a wide measurement range.
- Open Access
- 30 May 2024
- Published by Springer Nature in Research Square
Quantum Tunneling Noise-based Entropy Core for True Random Number Generation
Securing edge devices is crucial in today’s interconnected world, where the Internet of Things (IoT) is rapidly expanding. A “True Random Number Generator (TRNG)” is pivotal in ensuring the security of edge devices. However, strict area and power constraints are key requirements in edge applications. A high entropy source to facilitate an energy-efficient TRNG without adding extra area overhead is critical in safeguarding sensitive data and ensuring the integrity of edge computing environments. We propose a novel, experimentally validated, low area and low power entropy source that leverages inherent natural stochasticity in quantum tunneling current. In comparison with state-of-the-art TRNG architectures implemented in commercially available technologies, our innovative Quantum Tunneling-driven Ring Oscillator (QTRO) enables the TRNG with the lowest energy consumption of only 0.16 pJ/bit while also occupying the least area of only 81 μm2 in GF45RFSOI technology. The area and energy efficiency stem from quaint quantum nature – yet implemented on a mature VLSI technology. Our design is validated using NIST SP800-22 and SP800-90B randomness tests without the need to post-process the generated bitstream. We also validated our design against process, voltage, and temperature (PVT) variations, which shows resilience against potential security attacks.
- 30 May 2024
- Published by Springer Nature in Research Square
Open AccessQuantum Tunneling Noise-based Entropy Core for True Random Number Generation
Securing edge devices is crucial in today’s interconnected world, where the Internet of Things (IoT) is rapidly expanding. A “True Random Number Generator (TRNG)” is pivotal in ensuring the security of edge devices. However, strict area and power constraints are key requirements in edge applications. A high entropy source to facilitate an energy-efficient TRNG without adding extra area overhead is critical in safeguarding sensitive data and ensuring the integrity of edge computing environments. We propose a novel, experimentally validated, low area and low power entropy source that leverages inherent natural stochasticity in quantum tunneling current. In comparison with state-of-the-art TRNG architectures implemented in commercially available technologies, our innovative Quantum Tunneling-driven Ring Oscillator (QTRO) enables the TRNG with the lowest energy consumption of only 0.16 pJ/bit while also occupying the least area of only 81 μm2 in GF45RFSOI technology. The area and energy efficiency stem from quaint quantum nature – yet implemented on a mature VLSI technology. Our design is validated using NIST SP800-22 and SP800-90B randomness tests without the need to post-process the generated bitstream. We also validated our design against process, voltage, and temperature (PVT) variations, which shows resilience against potential security attacks.