Feasibility Analysis and Implementation of Head-Mounted Electrical Impedance Respiratory Monitoring
Open Access
- 27 October 2022
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 934
Abstract
The respiratory rate is one of the crucial indicators for monitoring human physiological health. The purpose of this paper was to introduce a head-mounted respiratory monitoring solution based on electrical impedance sensing. Firstly, we constructed a finite element model to analyze the feasibility of using head impedance for respiratory sensing based on the physiological changes in the pharynx. After that, we developed a circuit module that could be integrated into a head-mounted respiratory monitoring device using a bioelectrical impedance sensor. Furthermore, we combined adaptive filtering and respiratory tracking algorithms to develop an app for a mobile phone. Finally, we conducted controlled experiments to verify the effectiveness of this electrical impedance sensing system for extracting respiratory rate. We found that the respiration rates measured by the head-mounted electrical impedance respiratory monitoring system were not significantly different from those of commercial respiratory monitoring devices by a paired t-test (p > 0.05). The results showed that the respiratory rates of all subjects were within the 95% confidence interval. Therefore, the head-mounted respiratory monitoring scheme proposed in this paper was able to accurately measure respiratory rate, indicating the feasibility of this solution. In addition, this respiratory monitoring scheme helps to achieve real-time continuous respiratory monitoring, which can provide new insights for personalized health monitoring.Keywords
Funding Information
- National Natural Science Foundation of China (U1505251, SQ2021YFE012291, 2021I0005)
- the National Key R&D Program of China (U1505251, SQ2021YFE012291, 2021I0005)
- The Project of S&T Department of Fujian Province (U1505251, SQ2021YFE012291, 2021I0005)
This publication has 37 references indexed in Scilit:
- Ensemble Learning Approach via Kalman Filtering for a Passive Wearable Respiratory MonitorIEEE Journal of Biomedical and Health Informatics, 2018
- Gaming Away Stress: Using Biofeedback Games to Learn Paced BreathingIEEE Transactions on Affective Computing, 2018
- C-FMCW Based Contactless Respiration Detection Using Acoustic SignalProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, 2018
- Human emotion classification based on multiple physiological signals by wearable systemTechnology and Health Care, 2018
- pneuRIPTM: A Novel Respiratory Inductance Plethysmography MonitorJournal of Medical Devices, 2017
- Estimation of Respiratory Rates Using the Built-in Microphone of a Smartphone or HeadsetIEEE Journal of Biomedical and Health Informatics, 2015
- Optimizing electrical impedance myography measurements by using a multifrequency ratio: A study in Duchenne muscular dystrophyClinical Neurophysiology, 2015
- Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration MonitoringIEEE Sensors Journal, 2014
- Normal Respiratory Rate and Peripheral Blood Oxygen Saturation in the Elderly PopulationJournal of the American Geriatrics Society, 2013
- A Wireless Portable System With Microsensors for Monitoring Respiratory DiseasesIEEE Transactions on Biomedical Engineering, 2012