Yanyan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanyan Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hongli Yan
College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
1 shared publication - Jiejie Yang
Fuzhou University
1 shared publication - Wanting He
The International Joint Laboratory on Intelligent Health Monitoring Systems, Fuzhou University, Fuzhou 350108, China
1 shared publication - Xudong Yang
The International Joint Laboratory on Intelligent Health Monitoring Systems, Fuzhou University, Fuzhou 350108, China
1 shared publication - Yipeng Liao
Fujian Key Laboratory for Intelligent Processing and Wireless Transmission of Media Information, College of Physics and Information Engineering, Fuzhou University, Fuzhou, China
1 shared publication - Yueming Gao
College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
1 shared publication
Latest Publications
- Open Access
- 27 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 934
Feasibility Analysis and Implementation of Head-Mounted Electrical Impedance Respiratory Monitoring
The respiratory rate is one of the crucial indicators for monitoring human physiological health. The purpose of this paper was to introduce a head-mounted respiratory monitoring solution based on electrical impedance sensing. Firstly, we constructed a finite element model to analyze the feasibility of using head impedance for respiratory sensing based on the physiological changes in the pharynx. After that, we developed a circuit module that could be integrated into a head-mounted respiratory monitoring device using a bioelectrical impedance sensor. Furthermore, we combined adaptive filtering and respiratory tracking algorithms to develop an app for a mobile phone. Finally, we conducted controlled experiments to verify the effectiveness of this electrical impedance sensing system for extracting respiratory rate. We found that the respiration rates measured by the head-mounted electrical impedance respiratory monitoring system were not significantly different from those of commercial respiratory monitoring devices by a paired t-test (p > 0.05). The results showed that the respiratory rates of all subjects were within the 95% confidence interval. Therefore, the head-mounted respiratory monitoring scheme proposed in this paper was able to accurately measure respiratory rate, indicating the feasibility of this solution. In addition, this respiratory monitoring scheme helps to achieve real-time continuous respiratory monitoring, which can provide new insights for personalized health monitoring.
- 27 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 934
Open AccessFeasibility Analysis and Implementation of Head-Mounted Electrical Impedance Respiratory Monitoring
The respiratory rate is one of the crucial indicators for monitoring human physiological health. The purpose of this paper was to introduce a head-mounted respiratory monitoring solution based on electrical impedance sensing. Firstly, we constructed a finite element model to analyze the feasibility of using head impedance for respiratory sensing based on the physiological changes in the pharynx. After that, we developed a circuit module that could be integrated into a head-mounted respiratory monitoring device using a bioelectrical impedance sensor. Furthermore, we combined adaptive filtering and respiratory tracking algorithms to develop an app for a mobile phone. Finally, we conducted controlled experiments to verify the effectiveness of this electrical impedance sensing system for extracting respiratory rate. We found that the respiration rates measured by the head-mounted electrical impedance respiratory monitoring system were not significantly different from those of commercial respiratory monitoring devices by a paired t-test (p > 0.05). The results showed that the respiratory rates of all subjects were within the 95% confidence interval. Therefore, the head-mounted respiratory monitoring scheme proposed in this paper was able to accurately measure respiratory rate, indicating the feasibility of this solution. In addition, this respiratory monitoring scheme helps to achieve real-time continuous respiratory monitoring, which can provide new insights for personalized health monitoring.