Abstract
The efficiency of heart pump function greatly depends on synchronized contraction of myocardial muscle. In this work, contraction simulation of an excitable ventricular tissue cable was constructed to study the influence of excitation patterns on tissue contraction. The tissue cable is composed of elements which contract when excited by an external stimulus. In each calculation step, contraction force of each element is determined by a ventricular cell model. The mechanical deformation is then solved by finite element method and states of cells are updated accordingly. Several factors such as the starting position of the stimulation signal and the conduction velocity of gap-junctions affect contraction behavior. Simulation results show that the activation time, i.e. the time period the stimulation signal needs to spread over the tissue, is a dominant parameter for determining tissue contraction force. Contraction force of myocardial tissue increases monotonically with a decrease in activation time. This result suggests that minimization of activation time might be important for achieving effective tissue contractionKeywords
This publication has 12 references indexed in Scilit:
- Integration from proteins to organs: the Physiome ProjectNature Reviews Molecular Cell Biology, 2003
- Role of Individual Ionic Current Systems in Ventricular Cells Hypothesized by a Model StudyThe Japanese Journal of Physiology, 2003
- Optimizing ventricular fibers: uniform strain or stress, but not ATP consumption, leads to high efficiencyAmerican Journal of Physiology-Heart and Circulatory Physiology, 2002
- Mathematical modelling of the heart: cell to organChaos, Solitons & Fractals, 2002
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002
- Modelling cardiac mechanical properties in three dimensionsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2001
- Mechanisms underlying ventricular tachycardia and its transition to ventricular fibrillation in the structurally normal heartCardiovascular Research, 2001
- A dynamic model of the cardiac ventricular action potential. I. Simulations of ionic currents and concentration changes.Circulation Research, 1994
- A model of cardiac electrical activity incorporating ionic pumps and concentration changesPhilosophical Transactions of the Royal Society of London. B, Biological Sciences, 1985
- Reconstruction of the action potential of ventricular myocardial fibresThe Journal of Physiology, 1977