TMTetsuya Matsuda

Tetsuya Matsuda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tetsuya Matsuda has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fast Drug Action Solving from Cardiac Action Potential by Model Fitting in A Sampled Parameter Space

    by Jianyin Lu, Keichi Asakura, Akira Amano, Tetsuya Matsuda

    Model-based predictive approaches have been receiving increasing attention as a valuable tool to reduce cost in drug development. In this work, a model-fltting-based approach for solving drug actions using cardiac action potential recordings is investigated. Contribution of major ion currents in cardiac membrane excitation has been intensively studied. Cardiac cell models nowadays reproduce APs very precisely. Giving a test AP, the activities of involved ion channels can be determined by fitting the cell model to reproduce the test AP. Using experimental APs recordings both before and after drug dose, drug actions can be estimated by changes in channel activity. Due to the high computational cost in calculating cardiac models, a fast approach using only pre- calculated sample set is proposed. The searching strategy in the sampled space is divided into two steps: in the first step, the sample of best similarity comparing with the test AP is selected; then response surface approximation using the neighboring samples is followed and the estimation value is obtained by the approximated surface. This approach showed quite good estimation accuracy for a large number of simulation tests. Experiments using animal AP recordings from drug dose trials were also exemplified in which case the ICaL inhibition effect of nifedipine [10] was correctly discovered.

  • The Influence of Activation Time on Contraction Force of Myocardial Tissue: a Simulation Study

    by Jianyin Lu, Toshifumi Nishi, Takashi Ashihara, Natalie S. Schneider, Akira Amano, Tetsuya Matsuda, Hidetoshi Kotera

    The efficiency of heart pump function greatly depends on synchronized contraction of myocardial muscle. In this work, contraction simulation of an excitable ventricular tissue cable was constructed to study the influence of excitation patterns on tissue contraction. The tissue cable is composed of elements which contract when excited by an external stimulus. In each calculation step, contraction force of each element is determined by a ventricular cell model. The mechanical deformation is then solved by finite element method and states of cells are updated accordingly. Several factors such as the starting position of the stimulation signal and the conduction velocity of gap-junctions affect contraction behavior. Simulation results show that the activation time, i.e. the time period the stimulation signal needs to spread over the tissue, is a dominant parameter for determining tissue contraction force. Contraction force of myocardial tissue increases monotonically with a decrease in activation time. This result suggests that minimization of activation time might be important for achieving effective tissue contraction


  • Stress Distribution in a Rotationally Symmetric and a Measurement Based Left Ventricular Shape Model

    by Yasuhiro Takada, Akira Amano, Jianyin Lu, Takao Shimayoshi, Satoshi Ishikawa, Tetsuya Matsuda, Hidetoshi Kotera

    We evaluated the stress distribution in a geometrical shape model and a shape model obtained from human heart using two different fiber orientations. For both orientation models, the results showed large differences of the stress distributions between the mathematical shape model and the measurement based shape model. These results suggest that stress distribution is highly dependent on the model geometry and the usage of a measurement based shape model is important for the evaluation of the left ventricular (LV) wall stress distribution. This fact may have some influences on the reported homogeneity of stress distribution with anatomical fiber orientation model that uses mathematical shape model

  • The Influence of Activation Time on Contraction Force of Myocardial Tissue: a Simulation Study

    by Jianyin Lu, Toshifumi Nishi, Takashi Ashihara, Natalie S. Schneider, Akira Amano, Tetsuya Matsuda, Hidetoshi Kotera

    The efficiency of heart pump function greatly depends on synchronized contraction of myocardial muscle. In this work, contraction simulation of an excitable ventricular tissue cable was constructed to study the influence of excitation patterns on tissue contraction. The tissue cable is composed of elements which contract when excited by an external stimulus. In each calculation step, contraction force of each element is determined by a ventricular cell model. The mechanical deformation is then solved by finite element method and states of cells are updated accordingly. Several factors such as the starting position of the stimulation signal and the conduction velocity of gap-junctions affect contraction behavior. Simulation results show that the activation time, i.e. the time period the stimulation signal needs to spread over the tissue, is a dominant parameter for determining tissue contraction force. Contraction force of myocardial tissue increases monotonically with a decrease in activation time. This result suggests that minimization of activation time might be important for achieving effective tissue contraction

  • Stress Distribution in a Rotationally Symmetric and a Measurement Based Left Ventricular Shape Model

    by Yasuhiro Takada, Akira Amano, Jianyin Lu, Takao Shimayoshi, Satoshi Ishikawa, Tetsuya Matsuda, Hidetoshi Kotera

    We evaluated the stress distribution in a geometrical shape model and a shape model obtained from human heart using two different fiber orientations. For both orientation models, the results showed large differences of the stress distributions between the mathematical shape model and the measurement based shape model. These results suggest that stress distribution is highly dependent on the model geometry and the usage of a measurement based shape model is important for the evaluation of the left ventricular (LV) wall stress distribution. This fact may have some influences on the reported homogeneity of stress distribution with anatomical fiber orientation model that uses mathematical shape model