Brain Parcellation Repeatability and Reproducibility Using Conventional and Quantitative 3D MR Imaging
- 6 July 2023
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (8) , 910-915
Abstract
BACKGROUND AND PURPOSE: Automatic brain parcellation is typically performed on dedicated MR imaging sequences, which require valuable examination time. In this study, a 3D MR imaging quantification sequence to retrieve R1 and R2 relaxation rates and proton density maps was used to synthesize a T1-weighted image stack for brain volume measurement, thereby combining image data for multiple purposes. The repeatability and reproducibility of using the conventional and synthetic input data were evaluated. MATERIALS AND METHODS: Twelve subjects with a mean age of 54 years were scanned twice at 1.5T and 3T with 3D-QALAS and a conventionally acquired T1-weighted sequence. Using SyMRI, we converted the R1, R2, and proton density maps into synthetic T1-weighted images. Both the conventional T1-weighted and the synthetic 3D-T1-weighted inversion recovery images were processed for brain parcellation by NeuroQuant. Bland-Altman statistics were used to correlate the volumes of 12 brain structures. The coefficient of variation was used to evaluate the repeatability. RESULTS: A high correlation with medians of 0.97 for 1.5T and 0.92 for 3T was found. A high repeatability was shown with a median coefficient of variation of 1.2% for both T1-weighted and synthetic 3D-T1-weighted inversion recovery at 1.5T, and 1.5% for T1-weighted imaging and 4.4% for synthetic 3D-T1-weighted inversion recovery at 3T. However, significant biases were observed between the methods and field strengths. CONCLUSIONS: It is possible to perform MR imaging quantification of R1, R2, and proton density maps to synthesize a 3D-T1-weighted image stack, which can be used for automatic brain parcellation. Synthetic parameter settings should be reinvestigated to reduce the observed bias.Keywords
This publication has 13 references indexed in Scilit:
- Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: An accuracy and repeatability studyMagnetic Resonance Imaging, 2019
- Segmentation errors and intertest reliability in automated and manually traced hippocampal volumesAnnals of Clinical and Translational Neurology, 2019
- 3D quantitative synthetic MRI‐derived cortical thickness and subcortical brain volumes: Scan–rescan repeatability and comparison with conventional T1‐weighted imagesJournal of Magnetic Resonance Imaging, 2019
- Brain regional volume estimations with NeuroQuant and FIRST: a study in patients with a clinically isolated syndromeNeuroradiology, 2019
- Translational MRI Volumetry with NeuroQuant: Effects of Version and Normative Data on Relationships with Memory Performance in Healthy Older Adults and Patients with Mild Cognitive ImpairmentJournal of Alzheimer’s Disease, 2017
- Clinical feasibility of 3D-QALAS – Single breath-hold 3D myocardial T1- and T2-mappingMagnetic Resonance Imaging, 2017
- Predictive Utility of Marketed Volumetric Software Tools in Subjects at Risk for Alzheimer Disease: Do Regions Outside the Hippocampus Matter?American Journal of Neuroradiology, 2017
- Comparison of Automated Brain Volume Measures obtained with NeuroQuant® and FreeSurferJournal of Neuroimaging, 2015
- Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALASJournal of Cardiovascular Magnetic Resonance, 2014
- Magnetic resonance image synthesis from an interleaved saturation recovery/inversion recovery sequenceBritish Journal of Radiology, 1988