Jan B. M. Warntjes
Research Subjects
Jan B. M. Warntjes has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Anders Tisell
Departments of Medical Radiation Physics, Health and Caring Sciences, Linköping University, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Sweden
3 shared publications- Anders Tisell
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
3 shared publications P. Lundberg
From the Center for Medical Image Science and Visualization, (J.B.M.W., A.T., P.L.)Radiation Physics (P.L.), Department of Medical and Health Sciences, Linköping University, Linköping, SwedenRadiation Physics (P.L.), UHL, County Council of Östergötland, Linköping, Sweden
3 shared publications- Elna-Marie Larsson
Department of Surgical Sciences/Radiology, Uppsala University, Uppsala, Sweden
2 shared publications - Maria Engström
Linköping University
2 shared publications Peter Lundberg
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden; Radiation Physics, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
2 shared publications
Latest Publications
- 22 May 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (6) , 1196-1202
Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification
Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings. A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images. Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher). In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.
- 22 May 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (6) , 1196-1202
Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification
Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings. A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images. Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher). In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.
- Open Access
- 2 February 2025
- Published by Elsevier in World Neurosurgery
- Vol. 195, 123661
3D Quantitative MRI: A Fast and Reliable Method for Ventricular Volumetry
- 2 February 2025
- Published by Elsevier in World Neurosurgery
- Vol. 195, 123661
Open Access3D Quantitative MRI: A Fast and Reliable Method for Ventricular Volumetry
- 6 July 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (8) , 910-915
Brain Parcellation Repeatability and Reproducibility Using Conventional and Quantitative 3D MR Imaging
BACKGROUND AND PURPOSE: Automatic brain parcellation is typically performed on dedicated MR imaging sequences, which require valuable examination time. In this study, a 3D MR imaging quantification sequence to retrieve R1 and R2 relaxation rates and proton density maps was used to synthesize a T1-weighted image stack for brain volume measurement, thereby combining image data for multiple purposes. The repeatability and reproducibility of using the conventional and synthetic input data were evaluated. MATERIALS AND METHODS: Twelve subjects with a mean age of 54 years were scanned twice at 1.5T and 3T with 3D-QALAS and a conventionally acquired T1-weighted sequence. Using SyMRI, we converted the R1, R2, and proton density maps into synthetic T1-weighted images. Both the conventional T1-weighted and the synthetic 3D-T1-weighted inversion recovery images were processed for brain parcellation by NeuroQuant. Bland-Altman statistics were used to correlate the volumes of 12 brain structures. The coefficient of variation was used to evaluate the repeatability. RESULTS: A high correlation with medians of 0.97 for 1.5T and 0.92 for 3T was found. A high repeatability was shown with a median coefficient of variation of 1.2% for both T1-weighted and synthetic 3D-T1-weighted inversion recovery at 1.5T, and 1.5% for T1-weighted imaging and 4.4% for synthetic 3D-T1-weighted inversion recovery at 3T. However, significant biases were observed between the methods and field strengths. CONCLUSIONS: It is possible to perform MR imaging quantification of R1, R2, and proton density maps to synthesize a 3D-T1-weighted image stack, which can be used for automatic brain parcellation. Synthetic parameter settings should be reinvestigated to reduce the observed bias.
- 6 July 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (8) , 910-915
Brain Parcellation Repeatability and Reproducibility Using Conventional and Quantitative 3D MR Imaging
BACKGROUND AND PURPOSE: Automatic brain parcellation is typically performed on dedicated MR imaging sequences, which require valuable examination time. In this study, a 3D MR imaging quantification sequence to retrieve R1 and R2 relaxation rates and proton density maps was used to synthesize a T1-weighted image stack for brain volume measurement, thereby combining image data for multiple purposes. The repeatability and reproducibility of using the conventional and synthetic input data were evaluated. MATERIALS AND METHODS: Twelve subjects with a mean age of 54 years were scanned twice at 1.5T and 3T with 3D-QALAS and a conventionally acquired T1-weighted sequence. Using SyMRI, we converted the R1, R2, and proton density maps into synthetic T1-weighted images. Both the conventional T1-weighted and the synthetic 3D-T1-weighted inversion recovery images were processed for brain parcellation by NeuroQuant. Bland-Altman statistics were used to correlate the volumes of 12 brain structures. The coefficient of variation was used to evaluate the repeatability. RESULTS: A high correlation with medians of 0.97 for 1.5T and 0.92 for 3T was found. A high repeatability was shown with a median coefficient of variation of 1.2% for both T1-weighted and synthetic 3D-T1-weighted inversion recovery at 1.5T, and 1.5% for T1-weighted imaging and 4.4% for synthetic 3D-T1-weighted inversion recovery at 3T. However, significant biases were observed between the methods and field strengths. CONCLUSIONS: It is possible to perform MR imaging quantification of R1, R2, and proton density maps to synthesize a 3D-T1-weighted image stack, which can be used for automatic brain parcellation. Synthetic parameter settings should be reinvestigated to reduce the observed bias.
- Open Access
- 8 November 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (12) , 2194-2199
Synthesizing a Contrast-Enhancement Map in Patients with High-Grade Gliomas Based on a Postcontrast MR Imaging Quantification Only
BACKGROUND AND PURPOSE: Administration of a gadolinium-based contrast agent is an important diagnostic biomarker for blood-brain barrier damage. In clinical use, detection is based on subjective comparison of native and postgadolinium-based contrast agent T1-weighted images. Quantitative MR imaging studies have suggested a relation between the longitudinal relaxation rate and proton-density in the brain parenchyma, which is disturbed by gadolinium-based contrast agents. This discrepancy can be used to synthesize a contrast-enhancement map based solely on the postgadolinium-based contrast agent acquisition. The aim of this study was to compare synthetic enhancement maps with subtraction maps of native and postgadolinium-based contrast agent images. MATERIALS AND METHODS: For 14 patients with high-grade gliomas, quantitative MR imaging was performed before and after gadolinium-based contrast agent administration. The quantification sequence was multidynamic and multiecho, with a scan time of 6 minutes. The 2 image stacks were coregistered using in-plane transformation. The longitudinal relaxation maps were subtracted and correlated with the synthetic longitudinal relaxation enhancement maps on the basis of the postgadolinium-based contrast agent images only. ROIs were drawn for tumor delineation. RESULTS: Linear regression of the subtraction and synthetic longitudinal relaxation enhancement maps showed a slope of 1.02 ± 0.19 and an intercept of 0.05 ± 0.12. The Pearson correlation coefficient was 0.861 ± 0.059, and the coefficient of variation was 0.18 ± 0.04. On average, a volume of 1.71 ± 1.28 mL of low-intensity enhancement was detected in the synthetic enhancement maps outside the borders of the drawn ROI. CONCLUSIONS: The study shows that there was a good correlation between subtraction longitudinal relaxation enhancement maps and synthetic longitudinal relaxation enhancement maps in patients with high-grade gliomas. The method may improve the sensitivity and objectivity for the detection of gadolinium-based contrast agent enhancement.
- 8 November 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (12) , 2194-2199
Open AccessSynthesizing a Contrast-Enhancement Map in Patients with High-Grade Gliomas Based on a Postcontrast MR Imaging Quantification Only
BACKGROUND AND PURPOSE: Administration of a gadolinium-based contrast agent is an important diagnostic biomarker for blood-brain barrier damage. In clinical use, detection is based on subjective comparison of native and postgadolinium-based contrast agent T1-weighted images. Quantitative MR imaging studies have suggested a relation between the longitudinal relaxation rate and proton-density in the brain parenchyma, which is disturbed by gadolinium-based contrast agents. This discrepancy can be used to synthesize a contrast-enhancement map based solely on the postgadolinium-based contrast agent acquisition. The aim of this study was to compare synthetic enhancement maps with subtraction maps of native and postgadolinium-based contrast agent images. MATERIALS AND METHODS: For 14 patients with high-grade gliomas, quantitative MR imaging was performed before and after gadolinium-based contrast agent administration. The quantification sequence was multidynamic and multiecho, with a scan time of 6 minutes. The 2 image stacks were coregistered using in-plane transformation. The longitudinal relaxation maps were subtracted and correlated with the synthetic longitudinal relaxation enhancement maps on the basis of the postgadolinium-based contrast agent images only. ROIs were drawn for tumor delineation. RESULTS: Linear regression of the subtraction and synthetic longitudinal relaxation enhancement maps showed a slope of 1.02 ± 0.19 and an intercept of 0.05 ± 0.12. The Pearson correlation coefficient was 0.861 ± 0.059, and the coefficient of variation was 0.18 ± 0.04. On average, a volume of 1.71 ± 1.28 mL of low-intensity enhancement was detected in the synthetic enhancement maps outside the borders of the drawn ROI. CONCLUSIONS: The study shows that there was a good correlation between subtraction longitudinal relaxation enhancement maps and synthetic longitudinal relaxation enhancement maps in patients with high-grade gliomas. The method may improve the sensitivity and objectivity for the detection of gadolinium-based contrast agent enhancement.
- Open Access
- 14 December 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (2) , 296-302
Improved Precision of Automatic Brain Volume Measurements in Patients with Clinically Isolated Syndrome and Multiple Sclerosis Using Edema Correction
BACKGROUND AND PURPOSE: The presence of edema will result in increased brain volume, which may obscure progressing brain atrophy. Similarly, treatment-induced edema reduction may appear as accelerated brain tissue loss (pseudoatrophy). The purpose of this study was to correlate brain tissue properties to brain volume, to investigate the possibilities for edema correction and the resulting improvement of the precision of automated brain volume measurements. MATERIALS AND METHODS: A group of 38 patients with clinically isolated syndrome or newly diagnosed MS were imaged at inclusion and after 1, 2, and 4 years using an MR quantification sequence. Brain volume, relaxation rates (R1 and R2), and proton density were measured by automated software. RESULTS: The reduction of normalized brain volume with time after inclusion was 0.273%/year. The mean SDs were 0.508%, 0.526%, 0.454%, and 0.687% at baseline and 1, 2, and 4 years. Linear regression of the relative change of normalized brain volume and the relative change of R1, R2, and proton density showed slopes of −0.198 (P < .001), 0.156 (P = .04), and 0.488 (P < .001), respectively. After we applied the measured proton density as a correction factor, the mean SDs decreased to 24.2%, 4.8%, 33.3%, and 17.4%, respectively. The observed atrophy rate reduced from 0.273%/year to 0.238%/year. CONCLUSIONS: Correlations between volume and R1, R2, and proton density were observed in the brain, suggesting that a change of brain tissue properties can affect brain volume. Correction using these parameters decreased the variation of brain volume measurements and may have reduced the effect of pseudoatrophy.
- 14 December 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (2) , 296-302
Open AccessImproved Precision of Automatic Brain Volume Measurements in Patients with Clinically Isolated Syndrome and Multiple Sclerosis Using Edema Correction
BACKGROUND AND PURPOSE: The presence of edema will result in increased brain volume, which may obscure progressing brain atrophy. Similarly, treatment-induced edema reduction may appear as accelerated brain tissue loss (pseudoatrophy). The purpose of this study was to correlate brain tissue properties to brain volume, to investigate the possibilities for edema correction and the resulting improvement of the precision of automated brain volume measurements. MATERIALS AND METHODS: A group of 38 patients with clinically isolated syndrome or newly diagnosed MS were imaged at inclusion and after 1, 2, and 4 years using an MR quantification sequence. Brain volume, relaxation rates (R1 and R2), and proton density were measured by automated software. RESULTS: The reduction of normalized brain volume with time after inclusion was 0.273%/year. The mean SDs were 0.508%, 0.526%, 0.454%, and 0.687% at baseline and 1, 2, and 4 years. Linear regression of the relative change of normalized brain volume and the relative change of R1, R2, and proton density showed slopes of −0.198 (P < .001), 0.156 (P = .04), and 0.488 (P < .001), respectively. After we applied the measured proton density as a correction factor, the mean SDs decreased to 24.2%, 4.8%, 33.3%, and 17.4%, respectively. The observed atrophy rate reduced from 0.273%/year to 0.238%/year. CONCLUSIONS: Correlations between volume and R1, R2, and proton density were observed in the brain, suggesting that a change of brain tissue properties can affect brain volume. Correction using these parameters decreased the variation of brain volume measurements and may have reduced the effect of pseudoatrophy.
- Open Access
- 20 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1096-1102
Myelin Detection Using Rapid Quantitative MR Imaging Correlated to Macroscopically Registered Luxol Fast Blue–Stained Brain Specimens
BACKGROUND AND PURPOSE: Myelin detection is of great value in monitoring diseases such as multiple sclerosis and dementia. However, most MR imaging methods to measure myelin are challenging for routine clinical use. Recently, a novel method was published, in which the presence of myelin is inferred by using its effect on the intra- and extracellular water relaxation rates and proton density, observable by rapid quantitative MR imaging. The purpose of this work was to validate this method further on the brains of 12 fresh, intact cadavers. MATERIALS AND METHODS: The 12 brains were scanned with a quantification sequence to determine the longitudinal and transverse relaxation rates and proton density as input for the myelin estimations. Subsequently, the brains were excised at postmortem examination, and brain slices were stained with Luxol fast blue to verify the presence of myelin. The optical density values of photographs of the stained brain slices were registered with the MR images and correlated with the myelin estimation performed by quantitative MR imaging. RESULTS: A correlation was found between the 2 methods with a mean Spearman ρ for all subjects of 0.74 ± 0.11. Linear regression showed a mean intercept of 1.50% ± 2.84% and a mean slope of 4.37% ± 1.73%/%. A lower correlation was found for the separate longitudinal relaxation rates and proton density (ρ = 0.63 ± 0.12 and −0.73 ± 0.09, respectively). For transverse relaxation rates, the ρ was very low (0.11 ± 0.28). CONCLUSIONS: The observed correlation supports the validity of myelin measurement by using the MR imaging quantification method.
- 20 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1096-1102
Open AccessMyelin Detection Using Rapid Quantitative MR Imaging Correlated to Macroscopically Registered Luxol Fast Blue–Stained Brain Specimens
BACKGROUND AND PURPOSE: Myelin detection is of great value in monitoring diseases such as multiple sclerosis and dementia. However, most MR imaging methods to measure myelin are challenging for routine clinical use. Recently, a novel method was published, in which the presence of myelin is inferred by using its effect on the intra- and extracellular water relaxation rates and proton density, observable by rapid quantitative MR imaging. The purpose of this work was to validate this method further on the brains of 12 fresh, intact cadavers. MATERIALS AND METHODS: The 12 brains were scanned with a quantification sequence to determine the longitudinal and transverse relaxation rates and proton density as input for the myelin estimations. Subsequently, the brains were excised at postmortem examination, and brain slices were stained with Luxol fast blue to verify the presence of myelin. The optical density values of photographs of the stained brain slices were registered with the MR images and correlated with the myelin estimation performed by quantitative MR imaging. RESULTS: A correlation was found between the 2 methods with a mean Spearman ρ for all subjects of 0.74 ± 0.11. Linear regression showed a mean intercept of 1.50% ± 2.84% and a mean slope of 4.37% ± 1.73%/%. A lower correlation was found for the separate longitudinal relaxation rates and proton density (ρ = 0.63 ± 0.12 and −0.73 ± 0.09, respectively). For transverse relaxation rates, the ρ was very low (0.11 ± 0.28). CONCLUSIONS: The observed correlation supports the validity of myelin measurement by using the MR imaging quantification method.
- Open Access
- 17 February 2016
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 7, 16
Modeling the Presence of Myelin and Edema in the Brain Based on Multi-Parametric Quantitative MRI
The aim of this study was to present a model that uses multi-parametric quantitative MRI to estimate the presence of myelin and oedema in the brain. The model relates simultaneous measurement of R1 and R2 relaxation rates and proton density to four partial volume compartments, consisting of myelin partial volume, cellular partial volume, free water partial volume and excess parenchymal water partial volume. The model parameters were obtained using spatially normalised brain images of a group of 20 healthy controls. The pathological brain was modelled in terms of the reduction of myelin content and presence of excess parenchymal water, which indicates the degree of oedema. The method was tested on spatially normalised brain images of a group of 20 age-matched multiple sclerosis (MS) patients. Clear differences were observed with respect to the healthy controls: the MS group had a 79 mL smaller brain volume (1069 vs. 1148 mL), a 38 mL smaller myelin volume (119 vs. 157 mL) and a 21 mL larger excess parenchymal water volume (78 vs. 57 mL). Template regions of interest of various brain structures indicated that the myelin partial volume in the MS group was 1.6±1.5% lower for grey matter (GM) structures and 2.8±1.0% lower for white matter (WM) structures. The excess parenchymal water partial volume was 9±10% larger for GM and 5±2% larger for WM. Manually placed ROIs indicated that the results using the template ROIs may have suffered from loss of anatomical detail due to the spatial normalization process. Examples of the application of the method on high-resolution images are provided for three individual subjects, a 45-year-old healthy subject, a 72-year-old healthy subject and a 45-year-old MS patient. The observed results agreed with the expected behaviour considering both age and disease. In conclusion, the proposed model may provide clinically important parameters such as the total brain volume, degree of myelination and degree of oedema, based on a single qMRI acquisition with a clinically acceptable scan time.
- 17 February 2016
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 7, 16
Open AccessModeling the Presence of Myelin and Edema in the Brain Based on Multi-Parametric Quantitative MRI
The aim of this study was to present a model that uses multi-parametric quantitative MRI to estimate the presence of myelin and oedema in the brain. The model relates simultaneous measurement of R1 and R2 relaxation rates and proton density to four partial volume compartments, consisting of myelin partial volume, cellular partial volume, free water partial volume and excess parenchymal water partial volume. The model parameters were obtained using spatially normalised brain images of a group of 20 healthy controls. The pathological brain was modelled in terms of the reduction of myelin content and presence of excess parenchymal water, which indicates the degree of oedema. The method was tested on spatially normalised brain images of a group of 20 age-matched multiple sclerosis (MS) patients. Clear differences were observed with respect to the healthy controls: the MS group had a 79 mL smaller brain volume (1069 vs. 1148 mL), a 38 mL smaller myelin volume (119 vs. 157 mL) and a 21 mL larger excess parenchymal water volume (78 vs. 57 mL). Template regions of interest of various brain structures indicated that the myelin partial volume in the MS group was 1.6±1.5% lower for grey matter (GM) structures and 2.8±1.0% lower for white matter (WM) structures. The excess parenchymal water partial volume was 9±10% larger for GM and 5±2% larger for WM. Manually placed ROIs indicated that the results using the template ROIs may have suffered from loss of anatomical detail due to the spatial normalization process. Examples of the application of the method on high-resolution images are provided for three individual subjects, a 45-year-old healthy subject, a 72-year-old healthy subject and a 45-year-old MS patient. The observed results agreed with the expected behaviour considering both age and disease. In conclusion, the proposed model may provide clinically important parameters such as the total brain volume, degree of myelination and degree of oedema, based on a single qMRI acquisition with a clinically acceptable scan time.
- Open Access
- 24 December 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (5) , 797-801
Quantitative MRI for Rapid and User-Independent Monitoring of Intracranial CSF Volume in Hydrocephalus
BACKGROUND AND PURPOSE: Quantitative MR imaging allows segmentation of different tissue types and automatic calculation of intracranial volume, CSF volume, and brain parenchymal fraction. Brain parenchymal fraction is calculated as (intracranial volume – CSF volume) / intracranial volume. The purpose of this study was to evaluate whether the automatic calculation of intracranial CSF volume or brain parenchymal fraction could be used as an objective method to monitor volume changes in the ventricles. MATERIALS AND METHODS: A lumbar puncture with drainage of 40 mL of CSF was performed in 23 patients under evaluation for idiopathic normal pressure hydrocephalus. Quantitative MR imaging was performed twice within 1 hour before the lumbar puncture and was repeated 30 minutes, 4 hours, and 24 hours afterward. For each time point, the volume of the lateral ventricles was manually segmented and total intracranial CSF volume and brain parenchymal fraction were automatically calculated by using Synthetic MR postprocessing. RESULTS: At 30 minutes after the lumbar puncture, the volume of the lateral ventricles decreased by 5.6 ± 1.9 mL (P < .0001) and the total intracranial CSF volume decreased by 11.3 ± 5.6 mL (P < .001), while brain parenchymal fraction increased by 0.78% ± 0.41% (P < .001). Differences were significant for manual segmentation and brain parenchymal fraction even at 4 hours and 24 hours after the lumbar tap. There was a significant association using a linear mixed model between change in manually segmented ventricular volume and change in brain parenchymal fraction and total CSF volume, (P < .0001). CONCLUSIONS: Brain parenchymal fraction is provided rapidly and fully automatically with Synthetic MRI and can be used to monitor ventricular volume changes. The method may be useful for objective clinical monitoring of hydrocephalus.
- 24 December 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (5) , 797-801
Open AccessQuantitative MRI for Rapid and User-Independent Monitoring of Intracranial CSF Volume in Hydrocephalus
BACKGROUND AND PURPOSE: Quantitative MR imaging allows segmentation of different tissue types and automatic calculation of intracranial volume, CSF volume, and brain parenchymal fraction. Brain parenchymal fraction is calculated as (intracranial volume – CSF volume) / intracranial volume. The purpose of this study was to evaluate whether the automatic calculation of intracranial CSF volume or brain parenchymal fraction could be used as an objective method to monitor volume changes in the ventricles. MATERIALS AND METHODS: A lumbar puncture with drainage of 40 mL of CSF was performed in 23 patients under evaluation for idiopathic normal pressure hydrocephalus. Quantitative MR imaging was performed twice within 1 hour before the lumbar puncture and was repeated 30 minutes, 4 hours, and 24 hours afterward. For each time point, the volume of the lateral ventricles was manually segmented and total intracranial CSF volume and brain parenchymal fraction were automatically calculated by using Synthetic MR postprocessing. RESULTS: At 30 minutes after the lumbar puncture, the volume of the lateral ventricles decreased by 5.6 ± 1.9 mL (P < .0001) and the total intracranial CSF volume decreased by 11.3 ± 5.6 mL (P < .001), while brain parenchymal fraction increased by 0.78% ± 0.41% (P < .001). Differences were significant for manual segmentation and brain parenchymal fraction even at 4 hours and 24 hours after the lumbar tap. There was a significant association using a linear mixed model between change in manually segmented ventricular volume and change in brain parenchymal fraction and total CSF volume, (P < .0001). CONCLUSIONS: Brain parenchymal fraction is provided rapidly and fully automatically with Synthetic MRI and can be used to monitor ventricular volume changes. The method may be useful for objective clinical monitoring of hydrocephalus.
- Open Access
- 3 April 2014
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (7) , 1330-1336
Effects of Gadolinium Contrast Agent Administration on Automatic Brain Tissue Classification of Patients with Multiple Sclerosis
BACKGROUND AND PURPOSE: The administration of gadolinium contrast agent is a common part of MR imaging examinations in patients with MS. The presence of gadolinium may affect the outcome of automated tissue classification. The purpose of this study was to investigate the effects of the presence of gadolinium on the automatic segmentation in patients with MS by using the synthetic tissue-mapping method. MATERIALS AND METHODS: A cohort of 20 patients with clinically definite multiple sclerosis were recruited, and the T1 and T2 relaxation times and proton density were simultaneously quantified before and after the administration of gadolinium. Synthetic tissue-mapping was used to measure white matter, gray matter, CSF, brain parenchymal, and intracranial volumes. For comparison, 20 matched controls were measured twice, without gadolinium. RESULTS: No differences were observed for the control group between the 2 measurements. For the MS group, significant changes were observed pre- and post-gadolinium in intracranial volume (−13 mL, P < .005) and cerebrospinal fluid volume (−16 mL, P < .005) and the remaining, unclassified non-WM/GM/CSF tissue volume within the intracranial volume (+8 mL, P < .05). The changes in the patient group were much smaller than the differences, compared with the controls, which were −129 mL for WM volume, −22 mL for GM volume, +91 mL for CSF volume, 24 mL for the remaining, unclassified non-WM/GM/CSF tissue volume within the intracranial volume, and −126 mL for brain parenchymal volume. No significant differences were observed for linear regression values against age and Expanded Disability Status Scale. CONCLUSIONS: The administration of gadolinium contrast agent had a significant effect on automatic brain-tissue classification in patients with MS by using synthetic tissue-mapping. The observed differences, however, were much smaller than the group differences between MS and controls.
- 3 April 2014
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (7) , 1330-1336
Open AccessEffects of Gadolinium Contrast Agent Administration on Automatic Brain Tissue Classification of Patients with Multiple Sclerosis
BACKGROUND AND PURPOSE: The administration of gadolinium contrast agent is a common part of MR imaging examinations in patients with MS. The presence of gadolinium may affect the outcome of automated tissue classification. The purpose of this study was to investigate the effects of the presence of gadolinium on the automatic segmentation in patients with MS by using the synthetic tissue-mapping method. MATERIALS AND METHODS: A cohort of 20 patients with clinically definite multiple sclerosis were recruited, and the T1 and T2 relaxation times and proton density were simultaneously quantified before and after the administration of gadolinium. Synthetic tissue-mapping was used to measure white matter, gray matter, CSF, brain parenchymal, and intracranial volumes. For comparison, 20 matched controls were measured twice, without gadolinium. RESULTS: No differences were observed for the control group between the 2 measurements. For the MS group, significant changes were observed pre- and post-gadolinium in intracranial volume (−13 mL, P < .005) and cerebrospinal fluid volume (−16 mL, P < .005) and the remaining, unclassified non-WM/GM/CSF tissue volume within the intracranial volume (+8 mL, P < .05). The changes in the patient group were much smaller than the differences, compared with the controls, which were −129 mL for WM volume, −22 mL for GM volume, +91 mL for CSF volume, 24 mL for the remaining, unclassified non-WM/GM/CSF tissue volume within the intracranial volume, and −126 mL for brain parenchymal volume. No significant differences were observed for linear regression values against age and Expanded Disability Status Scale. CONCLUSIONS: The administration of gadolinium contrast agent had a significant effect on automatic brain-tissue classification in patients with MS by using synthetic tissue-mapping. The observed differences, however, were much smaller than the group differences between MS and controls.
- Open Access
- 5 August 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (8) , e70864
Brain Characterization Using Normalized Quantitative Magnetic Resonance Imaging
To present a method for generating reference maps of typical brain characteristics of groups of subjects using a novel combination of rapid quantitative Magnetic Resonance Imaging (qMRI) and brain normalization. The reference maps can be used to detect significant tissue differences in patients, both locally and globally. A rapid qMRI method was used to obtain the longitudinal relaxation rate (R1), the transverse relaxation rate (R2) and the proton density (PD). These three tissue properties were measured in the brains of 32 healthy subjects and in one patient diagnosed with Multiple Sclerosis (MS). The maps were normalized to a standard brain template using a linear affine registration. The differences of the mean value ofR1, R2 and PD of 31 healthy subjects in comparison to the oldest healthy subject and in comparison to an MS patient were calculated. Larger anatomical structures were characterized using a standard atlas. The vector sum of the normalized differences was used to show significant tissue differences. The coefficient of variation of the reference maps was high at the edges of the brain and the ventricles, moderate in the cortical grey matter and low in white matter and the deep grey matter structures. The elderly subject mainly showed significantly lower R1 and R2 and higher PD values along all sulci. The MS patient showed significantly lower R1 and R2 and higher PD values at the edges of the ventricular system as well as throughout the periventricular white matter, at the internal and external capsules and at each of the MS lesions. Brain normalization of rapid qMRI is a promising new method to generate reference maps of typical brain characteristics and to automatically detect deviating tissue properties in the brain.
- 5 August 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (8) , e70864
Open AccessBrain Characterization Using Normalized Quantitative Magnetic Resonance Imaging
To present a method for generating reference maps of typical brain characteristics of groups of subjects using a novel combination of rapid quantitative Magnetic Resonance Imaging (qMRI) and brain normalization. The reference maps can be used to detect significant tissue differences in patients, both locally and globally. A rapid qMRI method was used to obtain the longitudinal relaxation rate (R1), the transverse relaxation rate (R2) and the proton density (PD). These three tissue properties were measured in the brains of 32 healthy subjects and in one patient diagnosed with Multiple Sclerosis (MS). The maps were normalized to a standard brain template using a linear affine registration. The differences of the mean value ofR1, R2 and PD of 31 healthy subjects in comparison to the oldest healthy subject and in comparison to an MS patient were calculated. Larger anatomical structures were characterized using a standard atlas. The vector sum of the normalized differences was used to show significant tissue differences. The coefficient of variation of the reference maps was high at the edges of the brain and the ventricles, moderate in the cortical grey matter and low in white matter and the deep grey matter structures. The elderly subject mainly showed significantly lower R1 and R2 and higher PD values along all sulci. The MS patient showed significantly lower R1 and R2 and higher PD values at the edges of the ventricular system as well as throughout the periventricular white matter, at the internal and external capsules and at each of the MS lesions. Brain normalization of rapid qMRI is a promising new method to generate reference maps of typical brain characteristics and to automatically detect deviating tissue properties in the brain.