Independent component analysis for cochlear implant artifacts attenuation from electrically evoked auditory steady-state response measurements
- 6 December 2017
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (1) , 016006
Abstract
Objective . Electrically evoked auditory steady-state responses (EASSRs) are potentially useful for objective cochlear implant (CI) fitting and follow-up of the auditory maturation in infants and children with a CI. EASSRs are recorded in the electro-encephalogram (EEG) in response to electrical stimulation with continuous pulse trains, and are distorted by significant CI artifacts related to this electrical stimulation. The aim of this study is to evaluate a CI artifacts attenuation method based on independent component analysis (ICA) for three EASSR datasets. Approach . ICA has often been used to remove CI artifacts from the EEG to record transient auditory responses, such as cortical evoked auditory potentials. Independent components (ICs) corresponding to CI artifacts are then often manually identified. In this study, an ICA based CI artifacts attenuation method was developed and evaluated for EASSR measurements with varying CI artifacts and EASSR characteristics. Artifactual ICs were automatically identified based on their spectrum. Main results . For 40 Hz amplitude modulation (AM) stimulation at comfort level, in high SNR recordings, ICA succeeded in removing CI artifacts from all recording channels, without distorting the EASSR. For lower SNR recordings, with 40 Hz AM stimulation at lower levels, or 90 Hz AM stimulation, ICA either distorted the EASSR or could not remove all CI artifacts in most subjects, except for two of the seven subjects tested with low level 40 Hz AM stimulation. Noise levels were reduced after ICA was applied, and up to 29 ICs were rejected, suggesting poor ICA separation quality. Significance . We hypothesize that ICA is capable of separating CI artifacts and EASSR in case the contralateral hemisphere is EASSR dominated. For small EASSRs or large CI artifact amplitudes, ICA separation quality is insufficient to ensure complete CI artifacts attenuation without EASSR distortion.Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek (G.066213)
- Hermes Fonds (141243)
- Agentschap voor Innovatie door Wetenschap en Technologie (150432)
This publication has 43 references indexed in Scilit:
- Asymmetric Hearing During Development: The Aural Preference Syndrome and Treatment OptionsPediatrics, 2015
- Sound Coding in Cochlear Implants: From electric pulses to hearingIEEE Signal Processing Magazine, 2015
- Bilateral input protects the cortex from unilaterally-driven reorganization in children who are deafBrain, 2013
- Improved Electrically Evoked Auditory Steady-State Response Thresholds in HumansJournal of the Association for Research in Otolaryngology, 2012
- Electrically Evoked Auditory Steady State Responses in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2009
- Cortical development, plasticity and re-organization in children with cochlear implantsJournal of Communication Disorders, 2009
- Cortical reorganization in children with cochlear implantsBrain Research, 2008
- Deprivation-induced cortical reorganization in children with cochlear implantsInternational Journal of Audiology, 2007
- A Sensitive Period for the Development of the Central Auditory System in Children with Cochlear Implants: Implications for Age of ImplantationEar & Hearing, 2002
- The Relationship Between EAP and EABR Thresholds and Levels Used to Program the Nucleus 24 Speech Processor: Data from AdultsEar & Hearing, 2000