In-Situ Corrosion Testing of Carbon Steel and EHLA Clad Materials in High-Temperature Geothermal Well
Authors:
- Andri Isak ThorhallssonATAndri Isak Thorhallsson
- Gunnar Skulason KaldalGKGunnar Skulason Kaldal
- Thorri Jokull ThorsteinssonTTThorri Jokull Thorsteinsson
- Deirdre Elizabeth ClarkDCDeirdre Elizabeth Clark
- Erfan Abedi EsfahaniEEErfan Abedi Esfahani
- Tomaso MaccioTMTomaso Maccio
- Helen Osk HaraldsdottirHHHelen Osk Haraldsdottir
- Lilja TryggvadottirLTLilja Tryggvadottir
Open Access
- 8 December 2025
- journal article
- research article
- Published by MDPI AG in Corrosion and Materials Degradation
- Vol. 6 (4) , 65
Abstract
Carbon steel casing material in high-temperature deep geothermal wells can be prone to severe corrosion and premature failure due to the oxidation capacity of H2O, H2S, CO2, and more corrosive species in geothermal fluid. Due to the higher temperature and pressure and phase state of fluid in high-temperature deep geothermal wells, the rate and extent of corrosion can be expected to be different than in low-temperature geothermal wells. To reduce the extent of corrosion damage and corrosion rate, and increase the lifetime of geothermal wells, one mitigation method is to clad the internal surface of the geothermal casing with a more noble, corrosion-resistant material. Conventional cladding, however, has been an expensive and time-consuming process up to the current date, but recently, a more economical and productive method has been established, i.e., EHLA cladding. In this study, a 14-day corrosion performance test was conducted on stainless steel and nickel-based alloy clads on a carbon steel substrate in a 262 °C and 95 bar geothermal well in the Hellisheidi geothermal field (SW Iceland). Samples were partially or fully cladded, and some samples were stressed to investigate the clads’ susceptibility to general corrosion and stress corrosion cracking, as well as the substrate’s vulnerability to galvanic corrosion. Corrosion analysis of pure carbon steel substrate was also investigated for comparison. Samples were microstructurally analysed with SEM, and chemical analysis was performed with EDX. The results indicated that the clad materials have good corrosion resistance in the geothermal environment tested, suggesting that EHLA cladding is a more feasible option for strengthening the corrosion resistance of geothermal casing and equipment.Keywords
Funding Information
- European Union’s Horizon Europe research and innovation programmes (101084623)
This publication has 34 references indexed in Scilit:
- Status of high-speed laser cladding process: an up-to-date reviewProgress in Additive Manufacturing, 2023
- Modeling and Prediction of Galvanic Corrosion for an Overlaying Welded StructureJournal of Materials Engineering and Performance, 2023
- Role of pH and Eh in geothermal systems: Thermodynamic examples and impacts on scaling and corrosionGeothermics, 2023
- Corrosion behaviour of different steel types in artificial geothermal fluidsGeothermics, 2019
- Microstructural evolution and corrosion behaviour of thermally aged dissimilar metal welds of low-alloy steel and nickel-based alloyCorrosion Science, 2019
- Stress corrosion cracking failure of a SS 316L high pressure heater tubeEngineering Failure Analysis, 2018
- Formation of iron oxide and iron sulfide at high temperature and their effects on corrosionCorrosion Science, 2018
- Effects of chloride and oxygen on stress corrosion cracking of cold worked 316/316L austenitic stainless steel in high temperature waterCorrosion Science, 2016
- Corrosion and scaling as interrelated phenomena in an operating geothermal power plantCorrosion Science, 2013
- The effect of potential on stress corrosion cracking of type 316 and type 310 austenitic stainless steelsCorrosion Science, 1993